Status of digital output 14
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.9839.2.1.1.132
Status of digital output 14
Identification
{1 3 6 1 4 1 9839 2 1 1 132}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.9839.2.1.1.132.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
dout14 OBJECT-TYPE
SYNTAX Integer32 (0..1)
UNITS "N/A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Status of digital output 14"
::= { digitalObjects 132 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Status of digital output 14
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: current.
Names: dout14
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"dout14",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"1",
")",
"UNITS",
[
"literal",
"224e2f4122"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Status of digital output 14\"",
"::=",
"{",
"digitalObjects",
"132",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
1
]
]
]
],
[
"UNITS",
"N/A"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Status of digital output 14"
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive.
Module: CAREL-fcp-MIB
See published definition above
{'SNMPv2-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY'], 'SNMPv2-CONF': ['OBJECT-GROUP']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.9839.2.1.1.51 | alarmRHS, manual-reset-static-press-Alarm, glb-al, glb_al, all_ext_del, a1_e1, mal_maint_dev10, sel_rele_all_hf, cooling_heating, en_stampante, mal_oil_level, s_epromnook, a1_id, din107, def_ext_da | 0 | 0 | Alarm: Room Humidity Sensor Failed/Disconnected |
| 1.3.6.1.4.1.9839.2.1.1.52 | alarmCWOTS, enable-static-press-Warning, lead-comp, or-al-2lev, all_ext_ist, a1_e2, mal_maint_dev11, en_freecool, mal_low_pres, buzz_output, a2_hi, din108, anti_def_db | 0 | 0 | Alarm: Chilled Water Outlet T. Sensor Failed/Disconnected |
| 1.3.6.1.4.1.9839.2.1.1.53 | alarmC1Hours, manual-reset-static-press-Warning, wtrvlv-dir, range-t-ext, all_ha, a1_e3, mal_m_invdev1, cond_config, en_freeheat, mal_hp_transd, pro_pi, rele1_output, a2_lo, mall_term_klix1, end_def_de | 0 | 0 | ServiceAlarm: Compressor 1 hour counter threshold |
| 1.3.6.1.4.1.9839.2.1.1.54 | alarmC2Hours, enable-diff-press-Alarm, ups-on-alm, range-t-circ, all_hf, a1_ia, mal_broke_pr1, mal_serious, a2_ha, mall_term_klix2, sup_probe_a6 | 0 | 0 | ServiceAlarm: Compressor 2 hour counter threshold |
| 1.3.6.1.4.1.9839.2.1.1.55 | alarmC3Hours, manual-reset-diff-press-Alarm, pwrup-alm, range-t-man, all_sonda_amb, a1_da, mal_broke_pr2, ab_estate_inv_h6, en_compensazio, mal_fan1, si_sond_umid, a2_hf, mall_term_klix3, reset_alarm_p5 | 0 | 0 | ServiceAlarm: Compressor 3 hour counter threshold |
| 1.3.6.1.4.1.9839.2.1.1.56 | alarmC4Hours, enable-pressure-recovery, seetag-cust-alm1, range-t-ac, all_sonda_def, a1_ea, mal_broke_pr3, rotaz_compr_r5, inverter_steps, off_ventp_defr, mal_fan2, si_sond_acqua, a2_ed, mall_term_klix4, set_2_param_p6 | 0 | 0 | ServiceAlarm: Compressor 4 hour counter threshold |
| 1.3.6.1.4.1.9839.2.1.1.57 | alarmFilterHours, enable-Flow-Rate-Alarm, seetag-cust-alm2, umid-al, all_sonda_prod, a1_re, mal_pres_hpres, inverter, en_sbrin_cont, mal_pump_evap, si_sond_aria, mall_term_klix5, low_press_alarm_p7 | 0 | 0 | ServiceAlarm: Air Filter hour counter threshold |
| 1.3.6.1.4.1.9839.2.1.1.58 | alarmHeat1Hours, manual-reset-Flow-Rate-Alarm, seetag-cust-alm3, range-u-amb, all_sonda_reg, a1_id, mal_pres_lpres, fc_valve_type, autostart, mal_master_offl, si_sond_acquain, mall_term_klix6 | 0 | 0 | ServiceAlarm: Heater 1 hour counter threshold |
| 1.3.6.1.4.1.9839.2.1.1.59 | alarmHeat2Hours, enable-Flow-Rate-recovery, seetag-cust-alm4, all_tem_min_s1, a2_hi, mal_block_dev1, not_fc_vlv_type, en_remoto, mal_unit2_offl, si_sond_ariain, mall_pres_h1 | 0 | 0 | ServiceAlarm: Heater 1 hour counter threshold |
| 1.3.6.1.4.1.9839.2.1.1.60 | alarmHumHours, enable-pCOWeb, shortcycle-alm-en, k-syson, mal_block_dev2, unloads_logic, mal_unit3_offl, bin_sta, mall_pres_h2, def_cmd | 0 | 0 | ServiceAlarm: Humidifier hour counter threshold |
| 1.3.6.1.4.1.9839.2.1.1.61 | alarmUnitHours, fc-single-chiller, superv-off, xs-res-al, a2_ha, mal_block_dev3, valve4way_logic, mal_unit4_offl, si_rampap, mall_pres_h3 | 0 | 0 | ServiceAlarm: Unit hour counter threshold |
| 1.3.6.1.4.1.9839.2.1.1.62 | alarmDI2, BMS-heartbeat, a2_hf, mal_block_dev4, mal_b1, es, mall_pres_h4 | 0 | 0 | Alarm by Digital Input 2 |
| 1.3.6.1.4.1.9839.2.1.1.63 | alarmDI4, sleep-mode, mal_block_dev5, mal_b2, si_comp_es, mall_pres_h5 | 0 | 0 | Alarm by Digital Input 4 |
| 1.3.6.1.4.1.9839.2.1.1.64 | alarmDI6, test-sm, a4_hc, mal_block_dev6, abil_rotaz, mal_b3, si_rampan, mall_pres_h6 | 0 | 0 | Alarm by Digital Input 6 |
| 1.3.6.1.4.1.9839.2.1.1.65 | alarmHum, ab-mediath, a4_pd, mal_block_dev7, sys_on, mal_b4, si_parz, mall_dif_olio1 | 0 | 0 | Humidifier General Alarm |
| 1.3.6.1.4.1.9839.2.1.1.66 | alarmGeneral, ustdby1-2, a4_bp, mal_block_dev8, mal_b5, si_rot2, mall_dif_olio2 | 0 | 0 | General Alarm |
| 1.3.6.1.4.1.9839.2.1.1.67 | alarm2ndLevel, emerg, mal_block_dev9, mal_b6, si_comp1_deu, mall_dif_olio3 | 0 | 0 | Standby Unit Switchover Alarm |
| 1.3.6.1.4.1.9839.2.1.1.68 | alarmA, mal_block_dev10, mal_b7, si_comp2_deu, mall_dif_olio4 | 0 | 0 | Type A Alarm |
| 1.3.6.1.4.1.9839.2.1.1.69 | alarmB, mal_block_dev11, mal_b8, mall_dif_olio5 | 0 | 0 | Type B Alarm |
| 1.3.6.1.4.1.9839.2.1.1.70 | alarmC, mal_high1, glb_al, mal_pump_cond_h, mall_dif_olio6 | 0 | 0 | Type C Alarm |
| 1.3.6.1.4.1.9839.2.1.1.71 | selDXCW, digital_out_2, mal_low1, man_freeze, mal_comp_hour, si_fasce, mall_ore_comp1 | 0 | 0 | DX/CW Switch on TC Units |
| 1.3.6.1.4.1.9839.2.1.1.72 | selSW, mal_high2, mal_ov1, mal_pump_cond, mall_ore_comp2 | 0 | 0 | Summer/Winter Switchover |
| 1.3.6.1.4.1.9839.2.1.1.73 | digital_out_4, mal_low2, mal_ov2, mal_clock32, syson, mall_ore_comp3 | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.1.74 | mal_n_devices, mal_ov3, syson1, mal_phase, si_rampap3v, mall_ore_comp4 | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.1.75 | systemOnOff, al-idrofrigo-pump-c-1, digital_out_6, mepromnook, mal_ov4, en_binati, mal_ld_transd, si_rampan3v, mall_ore_comp5 | 0 | 0 | System On-Off |
| 1.3.6.1.4.1.9839.2.1.1.76 | resetAlarm, al-idrofrigo-pump-c-2, digital_out_7, mal_clock, mal_cflow, en_sond_text, mal_voltage, manuale, mall_ore_comp6 | 0 | 0 | Alarm Reset |
| 1.3.6.1.4.1.9839.2.1.1.77 | resetHrsFilt, digital_out_8, syson, mal_eflow, en_sond_uext, mal_current, start_off, mall_term_vent1 | 0 | 0 | Filter Run Hours Reset |
| 1.3.6.1.4.1.9839.2.1.1.78 | resetHrC1, digital_out_9, mal_hp1, en_sond_def1, mal_pump_ev_h, mall_term_vent2 | 0 | 0 | Compressor 1 Run Hours Reset |
| 1.3.6.1.4.1.9839.2.1.1.79 | resetHrC2, mal_hp2, en_sond_def2, mall_term_vent3 | 0 | 0 | Compressor 2 Run Hours Reset |
| 1.3.6.1.4.1.9839.2.1.1.80 | resetHrC3, al-idrofrigo-fl-C, mal_od1, mal_disch_temp, alarm_e06, mall_term_vent4 | 0 | 0 | Compressor 3 Run Hours Reset |
| 1.3.6.1.4.1.9839.2.1.1.81 | resetHrC4, mal_od2, mal_diff_pres, alarm_e08, mal_liquid_level | 0 | 0 | Compressor 4 Run Hours Reset |
| 1.3.6.1.4.1.9839.2.1.1.82 | resetStC1, mal_lp1, mal_alco1_67_r, alarm_e09, mall_pres_lpres | 0 | 0 | Compressor 1 Starting Counter Reset |
| 1.3.6.1.4.1.9839.2.1.1.83 | resetStC2, mal_lp2, mal_alco1_68_r, alarm_e10, mall_pres_hpres | 0 | 0 | Compressor 2 Starting Counter Reset |
| 1.3.6.1.4.1.9839.2.1.1.84 | resetStC3, mal_hpt1, mal_alco1_69_r, alarm_e11, mal_low2 | 0 | 0 | Compressor 3 Starting Counter Reset |
| 1.3.6.1.4.1.9839.2.1.1.85 | resetStC4, mal_hpt2, mal_alco1_70_r, alarm_e12, mall_alta_mand | 0 | 0 | Compressor 4 Starting Counter Reset |
| 1.3.6.1.4.1.9839.2.1.1.86 | resetHrH1, mal_serious, tipo_cont, mal_alco1_71_r, mal_low_press | 0 | 0 | Heater 1 Run Hours Reset |
| 1.3.6.1.4.1.9839.2.1.1.87 | resetHrH2, mal_f1_overload, mal_alco1_72_r, mal_high_press | 0 | 0 | Heater 2 Run Hours Reset |
| 1.3.6.1.4.1.9839.2.1.1.88 | resetStH1, sl_alm_1, mal_f2_overload, mal_alco1_73_r, mal_n_input | 0 | 0 | Heater 1 Starting Counter Reset |
| 1.3.6.1.4.1.9839.2.1.1.89 | resetStH2, mal_f3_overload, mal_alco1_74_r, mal_n_devices | 0 | 0 | Heater 2 Starting Counter Reset |
| 1.3.6.1.4.1.9839.2.1.1.90 | resetHrHU, mal_fan, mal_alco1_75_r, mall_ora | 0 | 0 | Humidifier Run Hours Reset |
| 1.3.6.1.4.1.9839.2.1.1.91 | resetStHU, mal_cpump, mal_alco1_760_r, mal_broke_pr1 | 0 | 0 | Humidifier Starting Counter Reset |
| 1.3.6.1.4.1.9839.2.1.1.92 | resetHrACU, mal_pump, mal_alco1_97_r, mal_broke_pr2 | 0 | 0 | Unit Run Hours Reset |
| 1.3.6.1.4.1.9839.2.1.1.93 | mal_unit1_offl, glb_al | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.1.94 | mal_unit2_offl | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.1.95 | sleepmode, sv_mst_defrost_end, mal_unit3_offl | 0 | 0 | Setback Mode (Sleep Mode) |
| 1.3.6.1.4.1.9839.2.1.1.96 | smtest, sv_mst_defrost_start, mal_unit4_offl | 0 | 0 | Sleep Mode Test |
| 1.3.6.1.4.1.9839.2.1.1.97 | enablemeanT, sw_door_brk, mal_b1 | 0 | 0 | Local/Mean Usage of Values |
| 1.3.6.1.4.1.9839.2.1.1.98 | mal_b2 | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.1.99 | mal_b3 | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.1.100 | c11-on, mal_b4 | 0 | 0 |