OID reference

hotGasCoil

1.3.6.1.4.1.9839.2.1.1.9

Description

Hot Gas Coil

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.9839.2.1.1 (digitalObjects)
Node code
9
Node names
  • hotGasCoil
  • static-press-alarm
  • floor-wtr-alm
  • al_hp_ckt1
  • gas-caldo-on
  • all_timeout_def
  • vent3
  • pressure_probe_from_master
  • defrost_priority
  • alrlowtempprobe2
  • all_sonda_1
  • device9
  • err_sonda_b3
  • dout_8
  • allarme_remoto
  • z9
  • fan_off_def_f3
  • rele1_pwup
  • fan_off_ctrl
  • rich_parz21
  • err_sonda_s1
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.9839.2.1.1.9
URN notation
urn:oid:1.3.6.1.4.1.9839.2.1.1.9
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 9839 2 1 1 9}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) digitalObjects(1) hotGasCoil(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) digitalObjects(1) static-press-alarm(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) digitalObjects(1) floor-wtr-alm(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) digitalObjects(1) gas-caldo-on(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) digitalObjects(1) vent3(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) digitalObjects(1) alrlowtempprobe2(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) digitalObjects(1) device9(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) digitalObjects(1) z9(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) digitalObjects(1) hotGasCoil(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) digitalObjects(1) static-press-alarm(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) digitalObjects(1) floor-wtr-alm(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) digitalObjects(1) gas-caldo-on(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) digitalObjects(1) vent3(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) digitalObjects(1) alrlowtempprobe2(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) digitalObjects(1) device9(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) digitalObjects(1) z9(9)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/9839/2/1/1/9
  • /ISO/Identified-Organization/6/1/4/1/9839/2/1/1/9
  • /ISO/3/6/1/4/1/9839/2/1/1/9
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/hotGasCoil
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/static-press-alarm
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/floor-wtr-alm
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/al_hp_ckt1
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/gas-caldo-on
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/all_timeout_def
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/vent3
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/pressure_probe_from_master
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/defrost_priority
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/alrlowtempprobe2
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/all_sonda_1
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/device9
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/err_sonda_b3
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/dout_8
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/allarme_remoto
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/digitalObjects/z9
  • Additional combinations skipped.

SNMP properties

Value type
Integer32
Units
N/A, flag, flags
Maximum access defined by MIB
read-only, read-write
Status in MIB
current
Default value
0, 1

Definitions may combine these properties differently.

Compare 7 source variants

Variant 1 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Allowed ranges
0–1

Variant 2 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Default value
0
Allowed ranges
0–1

Variant 3 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
flag
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
0
Allowed ranges
0–1

Variant 4 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
1
Allowed ranges
0–1

Variant 5 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
0
Allowed ranges
0–1

Variant 6 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current

Variant 7 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
flags
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
1
Allowed ranges
0–1

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.9839.2.1.1.9.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 22 distinct definitions; some records may not include a definition.

Show 22 published definitions

alrlowtempprobe2 · current

alrlowtempprobe2 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Alarm low temperature probe 2"
                    ::= { digitalObjects 9 }

all_sonda_1 · current

all_sonda_1 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Probe 2 error (er1)"
                    ::= { digitalObjects 9 }

floor-wtr-alm · current

floor-wtr-alm OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Water under floor alarm"
                    DEFVAL { 0 }
                    ::= { digitalObjects 9 }

err_sonda_s1 · current

err_sonda_s1 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Probe s1 faulty or not connected"
                    ::= { digitalObjects 9 }

dout_8 · current

dout_8 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Capacity control 3"
                    ::= { digitalObjects 9 }

all_sonda_1 · current

all_sonda_1 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Probe 2 error"
                    ::= { digitalObjects 9 }

rich_parz21 · current

rich_parz21 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Status of capacity-control 2 compressor 1"
                    ::= { digitalObjects 9 }

defrost_priority · current

defrost_priority OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "flag"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Defrost priority over compressor protection"
                    DEFVAL { 0 }
                    ::= { digitalObjects 9 }

hotGasCoil · current

hotGasCoil OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Hot Gas Coil"
                    ::= { digitalObjects 9 }

device9 · current

device9 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Status device 9"
                    ::= { digitalObjects 9 }

fan_off_ctrl · current

fan_off_ctrl OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Fans off when compressor off"
                    DEFVAL { 1 }
                    ::= { digitalObjects 9 }

static-press-alarm · current

static-press-alarm OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Water static pressure alarm"
                    ::= { digitalObjects 9 }

al_hp_ckt1 · current

al_hp_ckt1 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "high pressure on circuit 1"
                    ::= { digitalObjects 9 }

pressure_probe_from_master · current

pressure_probe_from_master OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Pressure probe from Master"
                    DEFVAL { 0 }
                    ::= { digitalObjects 9 }

rele1_pwup · current

rele1_pwup OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Output state on power-up at power-up"
                    DEFVAL { 0 }
                    ::= { digitalObjects 9 }

gas-caldo-on · current

gas-caldo-on OBJECT-TYPE
                    SYNTAX Integer32
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Hot Gas Coil"
                    ::= { digitalObjects 9 }

z9 · current

z9 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Resistance 1 thermal alarm digital input"
                    ::= { digitalObjects 9 }

err_sonda_b3 · current

err_sonda_b3 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Probe b3 faulty or not connected"
                    ::= { digitalObjects 9 }

fan_off_def_f3 · current

fan_off_def_f3 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "flags"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Fans off during defrost"
                    DEFVAL { 1 }
                    ::= { digitalObjects 9 }

allarme_remoto · current

allarme_remoto OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Remote alarm."
                    ::= { digitalObjects 9 }

vent3 · current

vent3 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Status of fan no.3"
                    ::= { digitalObjects 9 }

all_timeout_def · current

all_timeout_def OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Timeout defrost end"
                    ::= { digitalObjects 9 }

Meaning

Descriptions

21 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Hot Gas Coil
Original text from OID Repository
hotGasCoil OBJECT-TYPE
SYNTAX Integer32 (0..1)
UNITS "N/A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Hot Gas Coil"
Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 2 matching source records

OID Repository

View at oid-base.com

Description 2

Alarm low temperature probe 2

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 3

Probe 2 error (er1)

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 4

Water under floor alarm

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 5

Probe s1 faulty or not connected

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 6

Capacity control 3

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 7

Probe 2 error

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 8

Status of capacity-control 2 compressor 1

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 9

Defrost priority over compressor protection

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 10

Status device 9

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 11

Fans off when compressor off

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 12

Water static pressure alarm

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 13

high pressure on circuit 1

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 14

Pressure probe from Master

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 15

Output state on power-up at power-up

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 16

Resistance 1 thermal alarm digital input

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 17

Probe b3 faulty or not connected

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 18

Fans off during defrost

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 19

Remote alarm.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 20

Status of fan no.3

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 21

Timeout defrost end

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

22 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 2Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 2

alrlowtempprobe2 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: alrlowtempprobe2

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "alrlowtempprobe2",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Alarm low temperature probe 2\"",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Alarm low temperature probe 2"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 3Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 3

all_sonda_1 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: all_sonda_1

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "all_sonda_1",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Probe 2 error (er1)\"",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Probe 2 error (er1)"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 4Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 4

floor-wtr-alm · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)2 sources

Status in source: current.

Names: floor-wtr-alm

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "floor-wtr-alm",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Water under floor alarm\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Water under floor alarm"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 5Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 5

err_sonda_s1 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: err_sonda_s1

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "err_sonda_s1",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Probe s1 faulty or not connected\"",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Probe s1 faulty or not connected"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 6Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 6

dout_8 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: dout_8

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "dout_8",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Capacity control 3\"",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Capacity control 3"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 7Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 7

all_sonda_1 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: all_sonda_1

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "all_sonda_1",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Probe 2 error\"",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Probe 2 error"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 8Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 8

rich_parz21 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: rich_parz21

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rich_parz21",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Status of capacity-control 2 compressor 1\"",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Status of capacity-control 2 compressor 1"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 9Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 9

defrost_priority · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: defrost_priority

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "defrost_priority",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "22666c616722"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Defrost priority over compressor protection\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "flag"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Defrost priority over compressor protection"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)2 records · 2 sources

Description 1

hotGasCoil · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: hotGasCoil

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "hotGasCoil",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Hot Gas Coil\"",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Hot Gas Coil"
    ],
    null,
    null,
    null,
    null
  ]
}
gas-caldo-on · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: gas-caldo-on

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "gas-caldo-on",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Hot Gas Coil\"",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32"
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Hot Gas Coil"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 10Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 10

device9 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: device9

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "device9",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Status device 9\"",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Status device 9"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 11Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 11

fan_off_ctrl · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: fan_off_ctrl

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "fan_off_ctrl",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Fans off when compressor off\"",
    "DEFVAL",
    "{",
    "1",
    "}",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Fans off when compressor off"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      1
    ]
  ]
}
Records for description 12Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 12

static-press-alarm · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: static-press-alarm

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "static-press-alarm",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Water static pressure alarm\"",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Water static pressure alarm"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 13Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 13

al_hp_ckt1 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: al_hp_ckt1

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "al_hp_ckt1",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"high pressure on circuit 1\"",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "high pressure on circuit 1"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 14Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 14

pressure_probe_from_master · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: pressure_probe_from_master

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "pressure_probe_from_master",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Pressure probe from Master\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Pressure probe from Master"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 15Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 15

rele1_pwup · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: rele1_pwup

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rele1_pwup",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Output state on power-up at power-up\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Output state on power-up at power-up"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 16Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 16

z9 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: z9

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "z9",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Resistance 1 thermal alarm digital input\"",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Resistance 1 thermal alarm digital input"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 17Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 17

err_sonda_b3 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: err_sonda_b3

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "err_sonda_b3",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Probe b3 faulty or not connected\"",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Probe b3 faulty or not connected"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 18Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 18

fan_off_def_f3 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: fan_off_def_f3

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "fan_off_def_f3",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "22666c61677322"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Fans off during defrost\"",
    "DEFVAL",
    "{",
    "1",
    "}",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "flags"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Fans off during defrost"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      1
    ]
  ]
}
Records for description 19Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 19

allarme_remoto · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: allarme_remoto

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "allarme_remoto",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Remote alarm.\"",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Remote alarm."
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 20Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 20

vent3 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: vent3

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "vent3",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Status of fan no.3\"",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Status of fan no.3"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 21Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 21

all_timeout_def · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)2 sources

Status in source: current.

Names: all_timeout_def

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "all_timeout_def",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Timeout defrost end\"",
    "::=",
    "{",
    "digitalObjects",
    "9",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Timeout defrost end"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.9839)

Fiorindo Sebastiano

Siblings (185)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.9839.2.1.1.52 alarmCWOTS, enable-static-press-Warning, lead-comp, or-al-2lev, all_ext_ist, a1_e2, mal_maint_dev11, en_freecool, mal_low_pres, buzz_output, a2_hi, din108, anti_def_db00 Alarm: Chilled Water Outlet T. Sensor Failed/Disconnected
1.3.6.1.4.1.9839.2.1.1.53 alarmC1Hours, manual-reset-static-press-Warning, wtrvlv-dir, range-t-ext, all_ha, a1_e3, mal_m_invdev1, cond_config, en_freeheat, mal_hp_transd, pro_pi, rele1_output, a2_lo, mall_term_klix1, end_def_de00 ServiceAlarm: Compressor 1 hour counter threshold
1.3.6.1.4.1.9839.2.1.1.54 alarmC2Hours, enable-diff-press-Alarm, ups-on-alm, range-t-circ, all_hf, a1_ia, mal_broke_pr1, mal_serious, a2_ha, mall_term_klix2, sup_probe_a600 ServiceAlarm: Compressor 2 hour counter threshold
1.3.6.1.4.1.9839.2.1.1.55 alarmC3Hours, manual-reset-diff-press-Alarm, pwrup-alm, range-t-man, all_sonda_amb, a1_da, mal_broke_pr2, ab_estate_inv_h6, en_compensazio, mal_fan1, si_sond_umid, a2_hf, mall_term_klix3, reset_alarm_p500 ServiceAlarm: Compressor 3 hour counter threshold
1.3.6.1.4.1.9839.2.1.1.56 alarmC4Hours, enable-pressure-recovery, seetag-cust-alm1, range-t-ac, all_sonda_def, a1_ea, mal_broke_pr3, rotaz_compr_r5, inverter_steps, off_ventp_defr, mal_fan2, si_sond_acqua, a2_ed, mall_term_klix4, set_2_param_p600 ServiceAlarm: Compressor 4 hour counter threshold
1.3.6.1.4.1.9839.2.1.1.57 alarmFilterHours, enable-Flow-Rate-Alarm, seetag-cust-alm2, umid-al, all_sonda_prod, a1_re, mal_pres_hpres, inverter, en_sbrin_cont, mal_pump_evap, si_sond_aria, mall_term_klix5, low_press_alarm_p700 ServiceAlarm: Air Filter hour counter threshold
1.3.6.1.4.1.9839.2.1.1.58 alarmHeat1Hours, manual-reset-Flow-Rate-Alarm, seetag-cust-alm3, range-u-amb, all_sonda_reg, a1_id, mal_pres_lpres, fc_valve_type, autostart, mal_master_offl, si_sond_acquain, mall_term_klix600 ServiceAlarm: Heater 1 hour counter threshold
1.3.6.1.4.1.9839.2.1.1.59 alarmHeat2Hours, enable-Flow-Rate-recovery, seetag-cust-alm4, all_tem_min_s1, a2_hi, mal_block_dev1, not_fc_vlv_type, en_remoto, mal_unit2_offl, si_sond_ariain, mall_pres_h100 ServiceAlarm: Heater 1 hour counter threshold
1.3.6.1.4.1.9839.2.1.1.60 alarmHumHours, enable-pCOWeb, shortcycle-alm-en, k-syson, mal_block_dev2, unloads_logic, mal_unit3_offl, bin_sta, mall_pres_h2, def_cmd00 ServiceAlarm: Humidifier hour counter threshold
1.3.6.1.4.1.9839.2.1.1.61 alarmUnitHours, fc-single-chiller, superv-off, xs-res-al, a2_ha, mal_block_dev3, valve4way_logic, mal_unit4_offl, si_rampap, mall_pres_h300 ServiceAlarm: Unit hour counter threshold
1.3.6.1.4.1.9839.2.1.1.62 alarmDI2, BMS-heartbeat, a2_hf, mal_block_dev4, mal_b1, es, mall_pres_h400 Alarm by Digital Input 2
1.3.6.1.4.1.9839.2.1.1.63 alarmDI4, sleep-mode, mal_block_dev5, mal_b2, si_comp_es, mall_pres_h500 Alarm by Digital Input 4
1.3.6.1.4.1.9839.2.1.1.64 alarmDI6, test-sm, a4_hc, mal_block_dev6, abil_rotaz, mal_b3, si_rampan, mall_pres_h600 Alarm by Digital Input 6
1.3.6.1.4.1.9839.2.1.1.65 alarmHum, ab-mediath, a4_pd, mal_block_dev7, sys_on, mal_b4, si_parz, mall_dif_olio100 Humidifier General Alarm
1.3.6.1.4.1.9839.2.1.1.66 alarmGeneral, ustdby1-2, a4_bp, mal_block_dev8, mal_b5, si_rot2, mall_dif_olio200 General Alarm
1.3.6.1.4.1.9839.2.1.1.67 alarm2ndLevel, emerg, mal_block_dev9, mal_b6, si_comp1_deu, mall_dif_olio300 Standby Unit Switchover Alarm
1.3.6.1.4.1.9839.2.1.1.68 alarmA, mal_block_dev10, mal_b7, si_comp2_deu, mall_dif_olio400 Type A Alarm
1.3.6.1.4.1.9839.2.1.1.69 alarmB, mal_block_dev11, mal_b8, mall_dif_olio500 Type B Alarm
1.3.6.1.4.1.9839.2.1.1.70 alarmC, mal_high1, glb_al, mal_pump_cond_h, mall_dif_olio600 Type C Alarm
1.3.6.1.4.1.9839.2.1.1.71 selDXCW, digital_out_2, mal_low1, man_freeze, mal_comp_hour, si_fasce, mall_ore_comp100 DX/CW Switch on TC Units
1.3.6.1.4.1.9839.2.1.1.72 selSW, mal_high2, mal_ov1, mal_pump_cond, mall_ore_comp200 Summer/Winter Switchover
1.3.6.1.4.1.9839.2.1.1.73 digital_out_4, mal_low2, mal_ov2, mal_clock32, syson, mall_ore_comp300
1.3.6.1.4.1.9839.2.1.1.74 mal_n_devices, mal_ov3, syson1, mal_phase, si_rampap3v, mall_ore_comp400
1.3.6.1.4.1.9839.2.1.1.75 systemOnOff, al-idrofrigo-pump-c-1, digital_out_6, mepromnook, mal_ov4, en_binati, mal_ld_transd, si_rampan3v, mall_ore_comp500 System On-Off
1.3.6.1.4.1.9839.2.1.1.76 resetAlarm, al-idrofrigo-pump-c-2, digital_out_7, mal_clock, mal_cflow, en_sond_text, mal_voltage, manuale, mall_ore_comp600 Alarm Reset
1.3.6.1.4.1.9839.2.1.1.77 resetHrsFilt, digital_out_8, syson, mal_eflow, en_sond_uext, mal_current, start_off, mall_term_vent100 Filter Run Hours Reset
1.3.6.1.4.1.9839.2.1.1.78 resetHrC1, digital_out_9, mal_hp1, en_sond_def1, mal_pump_ev_h, mall_term_vent200 Compressor 1 Run Hours Reset
1.3.6.1.4.1.9839.2.1.1.79 resetHrC2, mal_hp2, en_sond_def2, mall_term_vent300 Compressor 2 Run Hours Reset
1.3.6.1.4.1.9839.2.1.1.80 resetHrC3, al-idrofrigo-fl-C, mal_od1, mal_disch_temp, alarm_e06, mall_term_vent400 Compressor 3 Run Hours Reset
1.3.6.1.4.1.9839.2.1.1.81 resetHrC4, mal_od2, mal_diff_pres, alarm_e08, mal_liquid_level00 Compressor 4 Run Hours Reset
1.3.6.1.4.1.9839.2.1.1.82 resetStC1, mal_lp1, mal_alco1_67_r, alarm_e09, mall_pres_lpres00 Compressor 1 Starting Counter Reset
1.3.6.1.4.1.9839.2.1.1.83 resetStC2, mal_lp2, mal_alco1_68_r, alarm_e10, mall_pres_hpres00 Compressor 2 Starting Counter Reset
1.3.6.1.4.1.9839.2.1.1.84 resetStC3, mal_hpt1, mal_alco1_69_r, alarm_e11, mal_low200 Compressor 3 Starting Counter Reset
1.3.6.1.4.1.9839.2.1.1.85 resetStC4, mal_hpt2, mal_alco1_70_r, alarm_e12, mall_alta_mand00 Compressor 4 Starting Counter Reset
1.3.6.1.4.1.9839.2.1.1.86 resetHrH1, mal_serious, tipo_cont, mal_alco1_71_r, mal_low_press00 Heater 1 Run Hours Reset
1.3.6.1.4.1.9839.2.1.1.87 resetHrH2, mal_f1_overload, mal_alco1_72_r, mal_high_press00 Heater 2 Run Hours Reset
1.3.6.1.4.1.9839.2.1.1.88 resetStH1, sl_alm_1, mal_f2_overload, mal_alco1_73_r, mal_n_input00 Heater 1 Starting Counter Reset
1.3.6.1.4.1.9839.2.1.1.89 resetStH2, mal_f3_overload, mal_alco1_74_r, mal_n_devices00 Heater 2 Starting Counter Reset
1.3.6.1.4.1.9839.2.1.1.90 resetHrHU, mal_fan, mal_alco1_75_r, mall_ora00 Humidifier Run Hours Reset
1.3.6.1.4.1.9839.2.1.1.91 resetStHU, mal_cpump, mal_alco1_760_r, mal_broke_pr100 Humidifier Starting Counter Reset
1.3.6.1.4.1.9839.2.1.1.92 resetHrACU, mal_pump, mal_alco1_97_r, mal_broke_pr200 Unit Run Hours Reset
1.3.6.1.4.1.9839.2.1.1.93 mal_unit1_offl, glb_al00
1.3.6.1.4.1.9839.2.1.1.94 mal_unit2_offl00
1.3.6.1.4.1.9839.2.1.1.95 sleepmode, sv_mst_defrost_end, mal_unit3_offl00 Setback Mode (Sleep Mode)
1.3.6.1.4.1.9839.2.1.1.96 smtest, sv_mst_defrost_start, mal_unit4_offl00 Sleep Mode Test
1.3.6.1.4.1.9839.2.1.1.97 enablemeanT, sw_door_brk, mal_b100 Local/Mean Usage of Values
1.3.6.1.4.1.9839.2.1.1.98 mal_b200
1.3.6.1.4.1.9839.2.1.1.99 mal_b300
1.3.6.1.4.1.9839.2.1.1.100 c11-on, mal_b400
1.3.6.1.4.1.9839.2.1.1.101 c12-on, mal_b5, syson00