Description 1
Suction termperature (evaporator outlet)
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.9839.2.1.2.67
Suction termperature (evaporator outlet)
Identification
{1 3 6 1 4 1 9839 2 1 2 67}
Definitions may combine these properties differently.
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.9839.2.1.2.67.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 3 distinct definitions; some records may not include a definition.
tmp_superheat OBJECT-TYPE
SYNTAX Integer32 (0..0)
UNITS "°C x10"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Suction termperature (evaporator outlet)"
DEFVAL { 0 }
::= { analogObjects 67 }fcs-out OBJECT-TYPE
SYNTAX Integer32 (0..1000)
UNITS "N/A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Fans speed controller output %"
::= { analogObjects 67 }set_vent1 OBJECT-TYPE
SYNTAX Integer32 (0..9990)
UNITS "°C x10"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Set-point fan 1: condensing control"
DEFVAL { 500 }
::= { analogObjects 67 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Suction termperature (evaporator outlet)
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 2
Fans speed controller output %
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Description 3
Set-point fan 1: condensing control
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: current.
Names: tmp_superheat
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"tmp_superheat",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"0",
")",
"UNITS",
[
"literal",
"22c2b0432078313022"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Suction termperature (evaporator outlet)\"",
"DEFVAL",
"{",
"0",
"}",
"::=",
"{",
"analogObjects",
"67",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
0
]
]
]
],
[
"UNITS",
"°C x10"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Suction termperature (evaporator outlet)"
],
null,
null,
null,
[
"DEFVAL",
0
]
]
}Vendor MIB copy from the Observium Community archive.
Module: CAREL-mastercase-MIB
See published definition above
{'SNMPv2-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY'], 'SNMPv2-CONF': ['OBJECT-GROUP']}Status in source: current.
Names: fcs-out
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"fcs-out",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"1000",
")",
"UNITS",
[
"literal",
"224e2f4122"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Fans speed controller output %\"",
"::=",
"{",
"analogObjects",
"67",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
1000
]
]
]
],
[
"UNITS",
"N/A"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Fans speed controller output %"
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: KELVIN-pCOWeb-Chiller-MIB
See published definition above
{'SNMPv2-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP']}Related source files and packages:
Status in source: current.
Names: set_vent1
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"set_vent1",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"0",
".",
".",
"9990",
")",
"UNITS",
[
"literal",
"22c2b0432078313022"
],
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Set-point fan 1: condensing control\"",
"DEFVAL",
"{",
"500",
"}",
"::=",
"{",
"analogObjects",
"67",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
0,
9990
]
]
]
],
[
"UNITS",
"°C x10"
],
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Set-point fan 1: condensing control"
],
null,
null,
null,
[
"DEFVAL",
500
]
]
}Vendor MIB copy from the Observium Community archive.
Module: CAREL-rtop_pco-MIB
See published definition above
{'SNMPv2-MIB': ['sysContact', 'sysName', 'sysLocation'], 'SNMPv2-SMI': ['enterprises', 'MODULE-IDENTITY'], 'SNMPv2-CONF': ['OBJECT-GROUP']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.9839.2.1.2.1 | roomTemp, setpoint-antifreeze1, ret-air-tmp, probeb3_rp, temp-amb, temp_ambiente, asp_conv, calibrazione_sonda_3, probeoffset_3, probe1, ing_sonda_0, probe_circ1, sonda_b1, ain_1, temp_aria_amb, temp, probe_0, h1, sonda_s1 | 0 | 0 | Room Temperature |
| 1.3.6.1.4.1.9839.2.1.2.2 | outdoorTemp, setpoint-antifreeze2, minmax-24hr-retair-maximum, probeb1_rn, temp-ext, temp_evap, press_mand_conv, calibr_sonda_ambiente, probeoffset_1, probe2, ing_sonda_1, probe_circ2, sonda_b2, ain_2, temp_aria_est, umid, probe_1, l1, sonda_s2_r6 | 0 | 0 | Ambient Temperature |
| 1.3.6.1.4.1.9839.2.1.2.3 | deliveryTemp, setpoint-Compensation, minmax-24hr-retair-minumum, probeb2_ro, temp-mand, set_point, set_comp, calibrazione_sonda_defrost, probeoffset_2, thrshitempprobe1, set_point1, setp_air_temp, sonda_b3, ain_3, acqua, probe_cal__c, h2, out_inv_fan, sonda_s3_r7, probe3 | 0 | 0 | Delivery Air Temperature |
| 1.3.6.1.4.1.9839.2.1.2.4 | cwTemp, hysteresis-Compensation, temp-setpoint, probeb4_rr, temp-circ, offset_probe, diff_comp, differenziale_alrm_ventole, fan_alarm_hyst, thrshitempprobe2, set_point2, inverter_fan, ain_4, aria_acqua_in, l2, inverter_comp1, sonda_s4_r8 | 0 | 0 | Chilled Water Temperature |
| 1.3.6.1.4.1.9839.2.1.2.5 | hwTemp, max-Compensation, temp-deadband, real_setp, temp-ac, control_delta, sg_bassa_asp, alrm_alta_temp, alarm_condenser, thrslotempprobe1, differenziale1, inverter_dev1, i_scala_press, ain_5, umid_ambiente, setpoint_valigia, temp_aria_man, h3, alarm_max_delta, set_comp, sonda_s5_r9 | 0 | 0 | Hot Water Temperature |
| 1.3.6.1.4.1.9839.2.1.2.6 | roomRH, setpoint-Differential, humidity-ain-offs, umid-amb, set_point_min, set_vent_off1, alrm_bassa_temp, alarm_condenser_delta, thrslotempprobe2, differenziale2, set_circuit1, f_scala_press, ain_6, umid_esterna, setpoint_poltrona, zona_morta, l3, alarm_min_delta, diff_comp, calibra_s1__6 | 0 | 0 | Room Relative Humidity |
| 1.3.6.1.4.1.9839.2.1.2.7 | cwoTemp, high-Limit, return-ain-offs, t-set, set_point_max, diff_vent, temp_ventole_on, zona_morta, set_c1_mask, calibra_b1, ain_7, setpoint_luna, banda_hum, h4, defrost_end_temp, set_fan, calibra_s2__7, temp_setp_st | 0 | 0 | Chilled Water Outlet Temperature |
| 1.3.6.1.4.1.9839.2.1.2.8 | evapPress1, low-Limit, cw-tmp, t-diff, defrost_end_temperature, sg_alta_asp, set_point_temperatura, offset_sonda, reduced_set, calibra_b2, ain_8, diffheat, set_hum_a, l4, fan_on_temp, diff_fan, calibra_s3__8, probe1_cal__c | 0 | 0 | Circuit 1 Evaporating Pressure |
| 1.3.6.1.4.1.9839.2.1.2.9 | evapPress2, max-Setpoint-Differential, disch-air-tmp, t-set-c, diff_alarm_fan, sg_alta_mand, temp_fine_sbrin, defrost_end_temp, sog_bassa_temp, set_inv_dev1, calibra_b3, analog_out_1, aout_1_display, sgl_l_temp, v3l, setpoint_min, voltage_in, calibra_s4__9 | 0 | 0 | Circuit 2 Evaporating Pressure |
| 1.3.6.1.4.1.9839.2.1.2.10 | suctTemp1, min-Setpoint-Differential, discharge-ain-offs, t-diff-c, sgl_alarm_min_rel, ins_comp, min_assegnaz_consentita_utente, fan_on_temp, sog_alta_temp, set_inv_fan, setp_estate, analog_out_2, sgl_h_temp, v3h, setpoint_max, max_set_co, calibra_s5__a | 0 | 0 | Circuit 1 Suction Temperature |
| 1.3.6.1.4.1.9839.2.1.2.11 | suctTemp2, setpoint-ASB-Inverter-pumps, cw-ain-offs, sum_setp_r1, ht-set, sgl_alarl_max_rel, dis_comp, max_assegnaz_consentita_utente, fan_on_cond, differenz_all, comp_setp, diff_estate, s_temp_setpoint, sgl_l_umid, v4l, setpoint_night, min_set_co, setp_est_r1 | 0 | 0 | Circuit 2 Suction Temperature |
| 1.3.6.1.4.1.9839.2.1.2.12 | evapTemp1, setpoint-DIFF-Inverter-pumps, engsaver-setpoint, win_setp_r9, lt-set, set_fan_off_rel, variaz_autom_setpoint_notturno, fan_cond_hyst, tempo_di_pwm, set_circuit2, setp_inverno, w_temp_setpoint, sgl_h_umid, v4h, reghyst, max_set_fa, differ_est_r2 | 0 | 0 | Circuit 1 Evap.Temperature |
| 1.3.6.1.4.1.9839.2.1.2.13 | evapTemp2, pressure-Out, opt1-analog, min_setp_t_ra, t-set-sm, delta_set_point, temperatura_rilev_max, setpoint_min, val_minimo_av, diff_circuit1, diff_inverno, cond_setpoint, set_temp_a, o1, max_store_value, min_set_fa, setp_inv_r3 | 0 | 0 | Circuit 2 Evap.Temperature |
| 1.3.6.1.4.1.9839.2.1.2.14 | ssh1, proportional-Band-Inverter-Pumps-PID, opt2-analog, max_setp_t_rb, t-set-c-sm, temperatura_rilev_min, setpoint_max, val_massimo_av, diff_circuit2, min_set_est, in_temp_setp, in_temp_band, o2, min_store_value, thresh_high1, differ_inv_r4 | 0 | 0 | Circuit 1 Superheat |
| 1.3.6.1.4.1.9839.2.1.2.15 | ssh2, integral-Time-Inverter-Pumps-PID, opt3-analog, sum_diff_r2, t-cw-dh, differenziale_regolatore, setpoint_night, set1_min_ok, thresh_low1, max_set_est, set_temp_ariae, o3, setpoint, diff_high1, set_min_est_ra, probe3_cal__8 | 0 | 0 | Circuit 2 Superheat |
| 1.3.6.1.4.1.9839.2.1.2.16 | coolRamp, derivative-Time-Inverter-Pumps-PID, opt4-analog, win_diff_r3, htset-cw, temp_minima_s1, reghyst, set1_max_ok, thresh_low2, min_set_inv, set_temp_ariai, o4, thresh_low1, set_max_est_rb | 0 | 0 | Cooling Valve Ramp |
| 1.3.6.1.4.1.9839.2.1.2.17 | heatRamp, hysteresis-Thermal-redundance, opt-sns-1-y1, n_zone_r4, t-set-cw, max_store_value, set2_min_ok, thresh_high1, max_set_inv, set_umid_est, banda_temp, ds1, diff_low1, set_min_inv_rc, probe2_cal__d | 0 | 0 | Heating Valve Ramp |
| 1.3.6.1.4.1.9839.2.1.2.18 | fanSpeed, min-Opening-3Way-Valve-Hydraulic, opt-sns-1-y2, hum_setp_r5, t-rc-es, tmp_evap_satura, min_store_value, set2_max_ok, thresh_high2, tmin_vel_est_f5, set_umid_inv, sgl_l_free, ds2, set_max_inv_rd | 0 | 0 | Evapor. Fan Speed |
| 1.3.6.1.4.1.9839.2.1.2.19 | opt-sns-1-ain-offs, max-Opening-3Way-Valve-Hydraulic, min_setp_h_rc, t-rc-est, setpoint, autorita, min_setp1, tmax_vel_est_f6, lim_sup_temp, sgl_h_free, ds3, diff_high2, tmin_vel_est_f5, temp_diff_rd | 0 | 0 | Analog Sensor 1 Calibration |
| 1.3.6.1.4.1.9839.2.1.2.20 | coolSetP, proportional-Band-3Way-Valve-Hydrauli-PID, opt-sns-2-y1, max_setp_h_rd, rampa-valv, superheat_set, min_setp2, tmin_vel_inv_f7, lim_inf_temp, ds4, thresh_low2, tmax_vel_est_f6 | 0 | 0 | Cooling Set Point |
| 1.3.6.1.4.1.9839.2.1.2.21 | coolDiff, setpoint-FCM, opt-sns-2-y2, diff_hum_r6, anaout2, k_int, max_setp1, tmax_vel_inv_f8, banda_temp_e, r1, s1, diff_low2, tmin_vel_inv_f7 | 0 | 0 | Cooling Prop.Band |
| 1.3.6.1.4.1.9839.2.1.2.22 | cool2SetP, hysteresis-FCM, opt-sns-2-ain-offs, diff_dehum_r7, steam-production, td_int, max_setp2, toff_fan_est_f9, banda_temp_i, s2, tmax_vel_inv_f8 | 0 | 0 | Cooling 2nd Set Point |
| 1.3.6.1.4.1.9839.2.1.2.23 | heatSetP, max-Out-Speed-FCM, opt-sns-3-y1, n_zone_h_r8, t-set-lm, lim_inf_int, diff_inv_dev1, toff_fan_inv_fa, lim_sup_umid, r8, s3, toff_fan_est_f9, aut_ngt_set_r4 | 0 | 0 | Heating Set point |
| 1.3.6.1.4.1.9839.2.1.2.24 | heat2SetP, min-Out-Speed-FCM, opt-sns-3-y2, authority_rg, delta-lm, offset_sh, diff_inv_fan, parametro_d3, lim_inf_umid, s4, toff_fan_inv_fa | 0 | 0 | Heating 2nd Set point |
| 1.3.6.1.4.1.9839.2.1.2.25 | heatDiff, hysteresis-Cut-off-FCM, opt-sns-3-ain-offs, s_setp_b2_rh, parametro_d4, diff_umid_e, r12, tp_start_def_d3 | 0 | 0 | Heating Prop.Band |
| 1.3.6.1.4.1.9839.2.1.2.26 | thrsHT, max-Pressure-Alarm-FCM, opt-sns-4-y1, w_setp_b2_ri, set_al_agelo_a1, diff_umid_i, r13, probe_1, tp_end_def_d4 | 0 | 0 | High Room Temperature Alarm Threshold |
| 1.3.6.1.4.1.9839.2.1.2.27 | thrsLT, hysteresis-Max-Pressure-Alarm-FCM, opt-sns-4-y2, diff_freec_rl, dif_al_agelo_a2, probe_2, set_vent_inv, set_al_agelo_a1, t_max_tm_rt_rh | 0 | 0 | Low Room Temperature Alarm Threshold |
| 1.3.6.1.4.1.9839.2.1.2.28 | smCoolSetp, max-Out-FCM, opt-sns-4-ain-offs, min_t_freec_rn, set_res_gelo_a4, offset_fcool, probe_3, diff_vent_inv, dif_al_agelo_a2, t_min_tm_rt_rl | 0 | 0 | Setback Mode: Cooling Setpoint |
| 1.3.6.1.4.1.9839.2.1.2.29 | smHeatSetp, min-Pressure-Alarm-FCM, delta_p6, dif_res_gelo_a5, diff_fcool, probe_virtual, set_res_gelo_a4 | 0 | 0 | Setback Mode: Heating Setpoint |
| 1.3.6.1.4.1.9839.2.1.2.30 | cwDehumSetp, hysteresis-Min-Pressure-Alarm-FCM, delta_p7, probe_1, lim_set_gelo_a7, offset_fheat, r9, power_supply_voltage, dif_res_gelo_a5 | 0 | 0 | CW Setpoint to Start Dehumidification |
| 1.3.6.1.4.1.9839.2.1.2.31 | cwHtThrsh, min-Out-FCM, delta_p8, probe_2, set_res_risc_a8, diff_fheat, r2 | 0 | 0 | CW High Temperature Alarm Threshold |
| 1.3.6.1.4.1.9839.2.1.2.32 | cwModeSetp, delta-Freecooling, delta_p9, dif_res_risc_a9, set_mandata, r4, seinverter | 0 | 0 | CW Setpoint to start CW Operating Mode (Only TC Units) |
| 1.3.6.1.4.1.9839.2.1.2.33 | radcoolSpES, hysteresis-Freecooling, diff_pd, set_all_at_pb, ban_mandata, c5, diff_inv | 0 | 0 | Radcooler Setpoint in Energy Saving Mode |
| 1.3.6.1.4.1.9839.2.1.2.34 | radcoolSpDX, proportional-Band-Freecooling-PID, min_fan_s_f5, sonda_b4, set_esterno, c6 | 0 | 0 | Radcooler Setpoint in DX Mode |
| 1.3.6.1.4.1.9839.2.1.2.35 | delTempLimit, offset-Freecooling-PID, max_fan_s_f6, diff_esterno_e | 0 | 0 | Delivery Temperature Low Limit Setpoint |
| 1.3.6.1.4.1.9839.2.1.2.36 | dtAutChgMLT, temperature-Overlap-Freecooling, probeconvl, max_comp_e | 0 | 0 | Delta Temperature for Automatic Mean/Local Changeover |
| 1.3.6.1.4.1.9839.2.1.2.37 | min-out-freecooling, probeconvh, set_min, f3 | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.2.38 | neutral-zone-K-costant, calibrazione_sonda_b1, set_stop, c7 | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.2.39 | neutral-zone-V-variable, calibrazione_sonda_b2, zona_morta, f4 | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.2.40 | proportional-Band-freecooling-Valve-PID, calibrazione_sonda_b3, zona_morta_u, p3 | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.2.41 | offset-Freecooling-Valve-PID, calibrazione_sonda_b4, sg_alta_in_e, p4 | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.2.42 | temperature-A-B, sg_bassa_in_e | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.2.43 | delta-Thermal-Excusion-Freecoling, sg_alta_in_i | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.2.44 | hysteresis-Thermal-Excusion-Freecoling, sg_bassa_in_i, d3 | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.2.45 | alarm-Setpoint-Static-Pressure-Hydraulic-circuit, d4 | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.2.46 | warnig-Setpoint-Static-Pressure-Hydraulic-circuit, d11, vis_temp_def_d | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.2.47 | alarm-Setpoint-Differential-Pressure-Hydraulic-circuit, vis_temp_3_da | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.2.48 | alarm-Setpoint-Flow-Rate-Hydraulic-circuit, tar_defrost1 | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.2.49 | tar_defrost2, fan_alrm_dif_a0 | 0 | 0 | |
| 1.3.6.1.4.1.9839.2.1.2.50 | tempertaure-Cut-off-FCM | 0 | 0 |