Reference record for OID 1.3.6.1.2.1.10.30.5.1.1


parent
1.3.6.1.2.1.10.30.5.1 (dsx3ConfigEntry)
node code
1
node name
dsx3LineIndex
dot oid
1.3.6.1.2.1.10.30.5.1.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) ds3(30) dsx3ConfigTable(5) dsx3ConfigEntry(1) dsx3LineIndex(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) ds3(30) dsx3ConfigTable(5) dsx3ConfigEntry(1) dsx3LineIndex(1)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) ds3(30) dsx3ConfigTable(5) dsx3ConfigEntry(1) dsx3LineIndex(1)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) ds3(30) dsx3ConfigTable(5) dsx3ConfigEntry(1) dsx3LineIndex(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) ds3(30) dsx3ConfigTable(5) dsx3ConfigEntry(1) dsx3LineIndex(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) ds3(30) dsx3ConfigTable(5) dsx3ConfigEntry(1) dsx3LineIndex(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/transmission/ds3/dsx3ConfigTable/dsx3ConfigEntry/dsx3LineIndex
  • /iso/identified-organization/dod/internet/mgmt/mib/transmission/ds3/dsx3ConfigTable/dsx3ConfigEntry/dsx3LineIndex
  • /iso/org/dod/internet/mgmt/mib-2/transmission/ds3/dsx3ConfigTable/dsx3ConfigEntry/dsx3LineIndex
  • /iso/org/dod/internet/mgmt/mib/transmission/ds3/dsx3ConfigTable/dsx3ConfigEntry/dsx3LineIndex
  • /iso/iso-identified-organization/dod/internet/mgmt/mib-2/transmission/ds3/dsx3ConfigTable/dsx3ConfigEntry/dsx3LineIndex
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/transmission/ds3/dsx3ConfigTable/dsx3ConfigEntry/dsx3LineIndex
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/10/30/5/1/1

    Description by circitor

    This object is the identifier of a DS3/E3
    Interface on a managed device. If there is an
    ifEntry that is directly associated with this
    and only this DS3/E3 interface, it should have
    the same value as ifIndex. Otherwise, number
    the dsx3LineIndices with an unique identifier
    following the rules of choosing a number that
    is greater than ifNumber and numbering the
    inside interfaces (e.g., equipment side) with
    even numbers and outside interfaces (e.g,
    network side) with odd numbers.

    Parsed from file RFC1407-MIB.mib
    Module: RFC1407-MIB

    Description by cisco_v1

    This object should be made equal to ifIndex. The
    next paragraph describes its previous usage.
    Making the object equal to ifIndex allows propoer
    use of ifStackTable.

    Previously, this object was the identifier of a
    DS3/E3 Interface on a managed device. If there is
    an ifEntry that is directly associated with this
    and only this DS3/E3 interface, it should have the
    same value as ifIndex. Otherwise, number the
    dsx3LineIndices with an unique identifier
    following the rules of choosing a number that is
    greater than ifNumber and numbering the inside
    interfaces (e.g., equipment side) with even
    numbers and outside interfaces (e.g, network side)
    with odd numbers.

    Description by mibdepot

    This object should be made equal to ifIndex. The
    next paragraph describes its previous usage.
    Making the object equal to ifIndex allows propoer
    use of ifStackTable.

    Previously, this object was the identifier of a
    DS3/E3 Interface on a managed device. If there is
    an ifEntry that is directly associated with this
    and only this DS3/E3 interface, it should have the
    same value as ifIndex. Otherwise, number the
    dsx3LineIndices with an unique identifier
    following the rules of choosing a number that is
    greater than ifNumber and numbering the inside
    interfaces (e.g., equipment side) with even


    numbers and outside interfaces (e.g, network side)
    with odd numbers.

    Parsed from file mib_txt_12_3_1_5.txt
    Company: None
    Module: ACC-MIB

    Description by cisco

    This object should be made equal to ifIndex. The
    next paragraph describes its previous usage.
    Making the object equal to ifIndex allows propoer
    use of ifStackTable.

    Previously, this object was the identifier of a
    DS3/E3 Interface on a managed device. If there is
    an ifEntry that is directly associated with this
    and only this DS3/E3 interface, it should have the
    same value as ifIndex. Otherwise, number the
    dsx3LineIndices with an unique identifier
    following the rules of choosing a number that is
    greater than ifNumber and numbering the inside
    interfaces (e.g., equipment side) with even
    numbers and outside interfaces (e.g, network side)
    with odd numbers.

    Information by circitor

    dsx3LineIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This object is the identifier of a DS3/E3 Interface on a managed device. If there is an ifEntry that is directly associated with this and only this DS3/E3 interface, it should have the same value as ifIndex. Otherwise, number the dsx3LineIndices with an unique identifier following the rules of choosing a number that is greater than ifNumber and numbering the inside interfaces (e.g., equipment side) with even numbers and outside interfaces (e.g, network side) with odd numbers." ::= { dsx3ConfigEntry 1 }

    Information by cisco_v1

    dsx3LineIndex OBJECT-TYPE SYNTAX InterfaceIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object should be made equal to ifIndex. The next paragraph describes its previous usage. Making the object equal to ifIndex allows propoer use of ifStackTable. Previously, this object was the identifier of a DS3/E3 Interface on a managed device. If there is an ifEntry that is directly associated with this and only this DS3/E3 interface, it should have the same value as ifIndex. Otherwise, number the dsx3LineIndices with an unique identifier following the rules of choosing a number that is greater than ifNumber and numbering the inside interfaces (e.g., equipment side) with even numbers and outside interfaces (e.g, network side) with odd numbers." ::= { dsx3ConfigEntry 1 }

    Information by oid_info

    Vendor: ADC Kentrox
    Module: RFC1407-MIB (rfc1407.mib)
    Type: TABULAR
    Access: read-only
    Syntax: INTEGER
    (
    1..65535 )

    Automatically extracted from www.mibdepot.com

    Information by mibdepot

    dsx3LineIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory ::= { dsx3ConfigEntry 1 }

    Information by cisco

    dsx3LineIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object should be made equal to ifIndex. The next paragraph describes its previous usage. Making the object equal to ifIndex allows propoer use of ifStackTable. Previously, this object was the identifier of a DS3/E3 Interface on a managed device. If there is an ifEntry that is directly associated with this and only this DS3/E3 interface, it should have the same value as ifIndex. Otherwise, number the dsx3LineIndices with an unique identifier following the rules of choosing a number that is greater than ifNumber and numbering the inside interfaces (e.g., equipment side) with even numbers and outside interfaces (e.g, network side) with odd numbers." ::= { dsx3ConfigEntry 1 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Brothers (17)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.10.30.5.1.2 dsx3IfIndex 0 0 This value for this object is equal to the
    value of ifIndex from the Interfaces table of
    MIB II (RFC 1213).
    1.3.6.1.2.1.10.30.5.1.3 dsx3TimeElapsed 0 0 The number of seconds that have elapsed since
    the beginning of the near end current error-
    measurement period.
    1.3.6.1.2.1.10.30.5.1.4 dsx3ValidIntervals 0 0 The number of previous near end intervals for
    which valid data was collected. The value will be
    96 unless the interface was brou…
    1.3.6.1.2.1.10.30.5.1.5 dsx3LineType 0 0 This variable indicates the variety of DS3 C-bit
    or E3 application
    implementing this interface. The type of
    interface affects the…
    1.3.6.1.2.1.10.30.5.1.6 dsx3LineCoding 0 0 This variable describes the variety of Zero Code
    Suppression used on this interface, which in turn
    affects a number of its charac…
    1.3.6.1.2.1.10.30.5.1.7 dsx3SendCode 0 0 This variable indicates what type of code is
    being sent across the DS3/E3 interface by the
    device. (These are optional for E3 in…
    1.3.6.1.2.1.10.30.5.1.8 dsx3CircuitIdentifier 0 0 This variable contains the transmission vendor's
    circuit identifier, for the purpose of
    facilitating troubleshooting.
    1.3.6.1.2.1.10.30.5.1.9 dsx3LoopbackConfig 0 0 This variable represents the loopback configuration
    of the DS3/E3 interface.
    The values mean:

    dsx3NoLoop
    Not in the loopback state.…
    1.3.6.1.2.1.10.30.5.1.10 dsx3LineStatus 0 0 This variable indicates the
    Line Status of the interface.
    It contains loopback state information
    and failure state information.
    The…
    1.3.6.1.2.1.10.30.5.1.11 dsx3TransmitClockSource 0 0 The source of Transmit Clock.
    is derived from the recovered receive clock of
    another DS3 interface.
    1.3.6.1.2.1.10.30.5.1.12 dsx3InvalidIntervals 0 0 The number of intervals for which no valid data
    is available.
    1.3.6.1.2.1.10.30.5.1.13 dsx3LineLength 0 0 The length of the ds3 line in meters. This
    object provides information for line build out
    circuitry if it exists and can use thi…
    1.3.6.1.2.1.10.30.5.1.14 dsx3LineStatusLastChange 0 0 The value of MIB II's sysUpTime object at the
    time this DS3/E3 entered its current line status
    state. If the current state was e…
    1.3.6.1.2.1.10.30.5.1.15 dsx3LineStatusChangeTrapEnable 0 0 Indicates whether dsx3LineStatusChange traps
    should be generated for this interface.
    1.3.6.1.2.1.10.30.5.1.16 dsx3LoopbackStatus 0 0 This variable represents the current state of the
    loopback on the DS3 interface. It contains
    information about loopbacks establi…
    1.3.6.1.2.1.10.30.5.1.17 dsx3Channelization 0 0 Indicates whether this ds3/e3 is channelized or
    unchannelized. The value of enabledDs1 indicates
    that this is a DS3 channelized …
    1.3.6.1.2.1.10.30.5.1.18 dsx3Ds1ForRemoteLoop 0 0 Indicates which ds1/e1 on this ds3/e3 will be
    indicated in the remote ds1 loopback request. A
    value of 0 means no DS1 will be lo…