This object is the identifier of a DS3/E3
Interface on a managed device. If there is an
ifEntry that is directly associated with this
and only this DS3/E3 interface, it should have
the same value as ifIndex. Otherwise, number
the dsx3LineIndices with an unique identifier
following the rules of choosing a number that
is greater than ifNumber and numbering the
inside interfaces (e.g., equipment side) with
even numbers and outside interfaces (e.g,
network side) with odd numbers.
Parsed from file RFC1407-MIB.mib
Module: RFC1407-MIB
This object should be made equal to ifIndex. The
next paragraph describes its previous usage.
Making the object equal to ifIndex allows propoer
use of ifStackTable.
Previously, this object was the identifier of a
DS3/E3 Interface on a managed device. If there is
an ifEntry that is directly associated with this
and only this DS3/E3 interface, it should have the
same value as ifIndex. Otherwise, number the
dsx3LineIndices with an unique identifier
following the rules of choosing a number that is
greater than ifNumber and numbering the inside
interfaces (e.g., equipment side) with even
numbers and outside interfaces (e.g, network side)
with odd numbers.
This object should be made equal to ifIndex. The
next paragraph describes its previous usage.
Making the object equal to ifIndex allows propoer
use of ifStackTable.
Previously, this object was the identifier of a
DS3/E3 Interface on a managed device. If there is
an ifEntry that is directly associated with this
and only this DS3/E3 interface, it should have the
same value as ifIndex. Otherwise, number the
dsx3LineIndices with an unique identifier
following the rules of choosing a number that is
greater than ifNumber and numbering the inside
interfaces (e.g., equipment side) with even
numbers and outside interfaces (e.g, network side)
with odd numbers.
Parsed from file mib_txt_12_3_1_5.txt
Company: None
Module: ACC-MIB
This object should be made equal to ifIndex. The
next paragraph describes its previous usage.
Making the object equal to ifIndex allows propoer
use of ifStackTable.
Previously, this object was the identifier of a
DS3/E3 Interface on a managed device. If there is
an ifEntry that is directly associated with this
and only this DS3/E3 interface, it should have the
same value as ifIndex. Otherwise, number the
dsx3LineIndices with an unique identifier
following the rules of choosing a number that is
greater than ifNumber and numbering the inside
interfaces (e.g., equipment side) with even
numbers and outside interfaces (e.g, network side)
with odd numbers.
dsx3LineIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This object is the identifier of a DS3/E3 Interface on a managed device. If there is an ifEntry that is directly associated with this and only this DS3/E3 interface, it should have the same value as ifIndex. Otherwise, number the dsx3LineIndices with an unique identifier following the rules of choosing a number that is greater than ifNumber and numbering the inside interfaces (e.g., equipment side) with even numbers and outside interfaces (e.g, network side) with odd numbers." ::= { dsx3ConfigEntry 1 }
dsx3LineIndex OBJECT-TYPE SYNTAX InterfaceIndex ACCESS read-only STATUS mandatory DESCRIPTION "This object should be made equal to ifIndex. The next paragraph describes its previous usage. Making the object equal to ifIndex allows propoer use of ifStackTable. Previously, this object was the identifier of a DS3/E3 Interface on a managed device. If there is an ifEntry that is directly associated with this and only this DS3/E3 interface, it should have the same value as ifIndex. Otherwise, number the dsx3LineIndices with an unique identifier following the rules of choosing a number that is greater than ifNumber and numbering the inside interfaces (e.g., equipment side) with even numbers and outside interfaces (e.g, network side) with odd numbers." ::= { dsx3ConfigEntry 1 }
Vendor: ADC Kentrox
Module: RFC1407-MIB (rfc1407.mib)
Type: TABULAR
Access: read-only
Syntax: INTEGER
(
1..65535 )
Automatically extracted from www.mibdepot.com
dsx3LineIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory ::= { dsx3ConfigEntry 1 }
dsx3LineIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object should be made equal to ifIndex. The next paragraph describes its previous usage. Making the object equal to ifIndex allows propoer use of ifStackTable. Previously, this object was the identifier of a DS3/E3 Interface on a managed device. If there is an ifEntry that is directly associated with this and only this DS3/E3 interface, it should have the same value as ifIndex. Otherwise, number the dsx3LineIndices with an unique identifier following the rules of choosing a number that is greater than ifNumber and numbering the inside interfaces (e.g., equipment side) with even numbers and outside interfaces (e.g, network side) with odd numbers." ::= { dsx3ConfigEntry 1 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.10.30.5.1.2 | dsx3IfIndex | 0 | 0 | This value for this object is equal to the value of ifIndex from the Interfaces table of MIB II (RFC 1213). |
1.3.6.1.2.1.10.30.5.1.3 | dsx3TimeElapsed | 0 | 0 | The number of seconds that have elapsed since the beginning of the near end current error- measurement period. |
1.3.6.1.2.1.10.30.5.1.4 | dsx3ValidIntervals | 0 | 0 | The number of previous near end intervals for which valid data was collected. The value will be 96 unless the interface was brou… |
1.3.6.1.2.1.10.30.5.1.5 | dsx3LineType | 0 | 0 | This variable indicates the variety of DS3 C-bit or E3 application implementing this interface. The type of interface affects the… |
1.3.6.1.2.1.10.30.5.1.6 | dsx3LineCoding | 0 | 0 | This variable describes the variety of Zero Code Suppression used on this interface, which in turn affects a number of its charac… |
1.3.6.1.2.1.10.30.5.1.7 | dsx3SendCode | 0 | 0 | This variable indicates what type of code is being sent across the DS3/E3 interface by the device. (These are optional for E3 in… |
1.3.6.1.2.1.10.30.5.1.8 | dsx3CircuitIdentifier | 0 | 0 | This variable contains the transmission vendor's circuit identifier, for the purpose of facilitating troubleshooting. |
1.3.6.1.2.1.10.30.5.1.9 | dsx3LoopbackConfig | 0 | 0 | This variable represents the loopback configuration of the DS3/E3 interface. The values mean: dsx3NoLoop Not in the loopback state.… |
1.3.6.1.2.1.10.30.5.1.10 | dsx3LineStatus | 0 | 0 | This variable indicates the Line Status of the interface. It contains loopback state information and failure state information. The… |
1.3.6.1.2.1.10.30.5.1.11 | dsx3TransmitClockSource | 0 | 0 | The source of Transmit Clock. is derived from the recovered receive clock of another DS3 interface. |
1.3.6.1.2.1.10.30.5.1.12 | dsx3InvalidIntervals | 0 | 0 | The number of intervals for which no valid data is available. |
1.3.6.1.2.1.10.30.5.1.13 | dsx3LineLength | 0 | 0 | The length of the ds3 line in meters. This object provides information for line build out circuitry if it exists and can use thi… |
1.3.6.1.2.1.10.30.5.1.14 | dsx3LineStatusLastChange | 0 | 0 | The value of MIB II's sysUpTime object at the time this DS3/E3 entered its current line status state. If the current state was e… |
1.3.6.1.2.1.10.30.5.1.15 | dsx3LineStatusChangeTrapEnable | 0 | 0 | Indicates whether dsx3LineStatusChange traps should be generated for this interface. |
1.3.6.1.2.1.10.30.5.1.16 | dsx3LoopbackStatus | 0 | 0 | This variable represents the current state of the loopback on the DS3 interface. It contains information about loopbacks establi… |
1.3.6.1.2.1.10.30.5.1.17 | dsx3Channelization | 0 | 0 | Indicates whether this ds3/e3 is channelized or unchannelized. The value of enabledDs1 indicates that this is a DS3 channelized … |
1.3.6.1.2.1.10.30.5.1.18 | dsx3Ds1ForRemoteLoop | 0 | 0 | Indicates which ds1/e1 on this ds3/e3 will be indicated in the remote ds1 loopback request. A value of 0 means no DS1 will be lo… |