The length of the ds3 line in meters. This
object provides information for line build out
circuitry if it exists and can use this object to
adjust the line build out.
Parsed from file DS3-MIB.mib
Module: DS3-MIB
The length of the ds3 line in meters. This
object provides information for line build out
circuitry if it exists and can use this object to
adjust the line build out.
dsx3LineLength OBJECT-TYPE
SYNTAX INTEGER (0..64000)
UNITS "meters"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The length of the ds3 line in meters. This
object provides information for line build out
circuitry if it exists and can use this object to
adjust the line build out."
View at oid-info.com
The length of the ds3 line in meters. This
object provides information for line build out
circuitry if it exists and can use this object to
adjust the line build out.
Parsed from file DS3-MIB.txt
Company: None
Module: DS3-MIB
The length of the ds3 line in meters. This
object provides information for line build out
circuitry if it exists and can use this object to
adjust the line build out.
dsx3LineLength OBJECT-TYPE SYNTAX INTEGER (0..64000) UNITS "meters" MAX-ACCESS read-write STATUS current DESCRIPTION "The length of the ds3 line in meters. This object provides information for line build out circuitry if it exists and can use this object to adjust the line build out." ::= { dsx3ConfigEntry 13 }
dsx3LineLength OBJECT-TYPE SYNTAX INTEGER(0..64000) ACCESS read-write STATUS mandatory DESCRIPTION "The length of the ds3 line in meters. This object provides information for line build out circuitry if it exists and can use this object to adjust the line build out." ::= { dsx3ConfigEntry 13 }
Automatically extracted from Cisco "SNMP v2 MIBs".
dsx3LineLength OBJECT-TYPE SYNTAX INTEGER (0..64000) UNITS "meters" MAX-ACCESS read-write STATUS current DESCRIPTION "The length of the ds3 line in meters. This object provides information for line build out circuitry if it exists and can use this object to adjust the line build out." ::= { dsx3ConfigEntry 13 }
dsx3LineLength OBJECT-TYPE SYNTAX INTEGER (0..64000) UNITS "meters" MAX-ACCESS read-write STATUS current DESCRIPTION "The length of the ds3 line in meters. This object provides information for line build out circuitry if it exists and can use this object to adjust the line build out." ::= { dsx3ConfigEntry 13 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.10.30.5.1.1 | dsx3LineIndex | 0 | 0 | This object is the identifier of a DS3/E3 Interface on a managed device. If there is an ifEntry that is directly associated with… |
1.3.6.1.2.1.10.30.5.1.2 | dsx3IfIndex | 0 | 0 | This value for this object is equal to the value of ifIndex from the Interfaces table of MIB II (RFC 1213). |
1.3.6.1.2.1.10.30.5.1.3 | dsx3TimeElapsed | 0 | 0 | The number of seconds that have elapsed since the beginning of the near end current error- measurement period. |
1.3.6.1.2.1.10.30.5.1.4 | dsx3ValidIntervals | 0 | 0 | The number of previous near end intervals for which valid data was collected. The value will be 96 unless the interface was brou… |
1.3.6.1.2.1.10.30.5.1.5 | dsx3LineType | 0 | 0 | This variable indicates the variety of DS3 C-bit or E3 application implementing this interface. The type of interface affects the… |
1.3.6.1.2.1.10.30.5.1.6 | dsx3LineCoding | 0 | 0 | This variable describes the variety of Zero Code Suppression used on this interface, which in turn affects a number of its charac… |
1.3.6.1.2.1.10.30.5.1.7 | dsx3SendCode | 0 | 0 | This variable indicates what type of code is being sent across the DS3/E3 interface by the device. (These are optional for E3 in… |
1.3.6.1.2.1.10.30.5.1.8 | dsx3CircuitIdentifier | 0 | 0 | This variable contains the transmission vendor's circuit identifier, for the purpose of facilitating troubleshooting. |
1.3.6.1.2.1.10.30.5.1.9 | dsx3LoopbackConfig | 0 | 0 | This variable represents the loopback configuration of the DS3/E3 interface. The values mean: dsx3NoLoop Not in the loopback state.… |
1.3.6.1.2.1.10.30.5.1.10 | dsx3LineStatus | 0 | 0 | This variable indicates the Line Status of the interface. It contains loopback state information and failure state information. The… |
1.3.6.1.2.1.10.30.5.1.11 | dsx3TransmitClockSource | 0 | 0 | The source of Transmit Clock. is derived from the recovered receive clock of another DS3 interface. |
1.3.6.1.2.1.10.30.5.1.12 | dsx3InvalidIntervals | 0 | 0 | The number of intervals for which no valid data is available. |
1.3.6.1.2.1.10.30.5.1.14 | dsx3LineStatusLastChange | 0 | 0 | The value of MIB II's sysUpTime object at the time this DS3/E3 entered its current line status state. If the current state was e… |
1.3.6.1.2.1.10.30.5.1.15 | dsx3LineStatusChangeTrapEnable | 0 | 0 | Indicates whether dsx3LineStatusChange traps should be generated for this interface. |
1.3.6.1.2.1.10.30.5.1.16 | dsx3LoopbackStatus | 0 | 0 | This variable represents the current state of the loopback on the DS3 interface. It contains information about loopbacks establi… |
1.3.6.1.2.1.10.30.5.1.17 | dsx3Channelization | 0 | 0 | Indicates whether this ds3/e3 is channelized or unchannelized. The value of enabledDs1 indicates that this is a DS3 channelized … |
1.3.6.1.2.1.10.30.5.1.18 | dsx3Ds1ForRemoteLoop | 0 | 0 | Indicates which ds1/e1 on this ds3/e3 will be indicated in the remote ds1 loopback request. A value of 0 means no DS1 will be lo… |