An ASCII string containing the 8 flags representing
the current alarm state of the ARU. If the state of
the ARU is unknown, this variable is set to 'UNKNOWN'.
The flags are numbered 1 to 8, read from left to
right. The flags are defined as follows:
Flag 1: Fan Fail 1
Flag 2: Fan Fail 2
Flag 3: Fan Fail 3
Flag 4: Smoke (if ARU is equipped with smoke detector)
Flag 5: High Temp (Out of Thermal Control)
Flag 6: Over Temp (Exhaust Temp. Exceeds Override Setpoint)
Flag 7: Fan Fail 4 (Gen 2 ARU only)
Flag 8: Reserved
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
An ASCII string containing the 8 flags representing
the current alarm state of the ARU. If the state of
the ARU is unknown, this variable is set to 'UNKNOWN'.
The flags are numbered 1 to 8, read from left to
right. The flags are defined as follows:
Flag 1: Fan Fail 1
Flag 2: Fan Fail 2
Flag 3: Fan Fail 3
Flag 4: Smoke (if ARU is equipped with smoke detector)
Flag 5: High Temp (Out of Thermal Control)
Flag 6: Over Temp (Exhaust Temp. Exceeds Override Setpoint)
Flag 7: Fan Fail 4 (Gen 2 ARU only)
Flag 8: Reserved
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
rARUStatusAruAlarmState OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "An ASCII string containing the 8 flags representing the current alarm state of the ARU. If the state of the ARU is unknown, this variable is set to 'UNKNOWN'. The flags are numbered 1 to 8, read from left to right. The flags are defined as follows: Flag 1: Fan Fail 1 Flag 2: Fan Fail 2 Flag 3: Fan Fail 3 Flag 4: Smoke (if ARU is equipped with smoke detector) Flag 5: High Temp (Out of Thermal Control) Flag 6: Over Temp (Exhaust Temp. Exceeds Override Setpoint) Flag 7: Fan Fail 4 (Gen 2 ARU only) Flag 8: Reserved" ::= { rARUStatusEntry 10 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
rARUStatusAruAlarmState OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "An ASCII string containing the 8 flags representing the current alarm state of the ARU. If the state of the ARU is unknown, this variable is set to 'UNKNOWN'. The flags are numbered 1 to 8, read from left to right. The flags are defined as follows: Flag 1: Fan Fail 1 Flag 2: Fan Fail 2 Flag 3: Fan Fail 3 Flag 4: Smoke (if ARU is equipped with smoke detector) Flag 5: High Temp (Out of Thermal Control) Flag 6: Over Temp (Exhaust Temp. Exceeds Override Setpoint) Flag 7: Fan Fail 4 (Gen 2 ARU only) Flag 8: Reserved" ::= { rARUStatusEntry 10 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.14.3.3.1.1 | rARUStatusAruIndex | 0 | 0 | The index to the ARU entry. |
1.3.6.1.4.1.318.1.1.14.3.3.1.2 | rARUStatusAruName | 0 | 0 | The name of the ARU. |
1.3.6.1.4.1.318.1.1.14.3.3.1.3 | rARUStatusAruRemoteSetpoint | 0 | 0 | This OID defines the desired base airflow of the ARU, or the speed of the ARU fans when the temperature override is inactive. See… |
1.3.6.1.4.1.318.1.1.14.3.3.1.4 | rARUStatusAruManualSetpoint | 0 | 0 | Manual operating setpoint of the ARU, which is set on the panel of the ARU. If the ARU doesn't have a manual , the OID will alway… |
1.3.6.1.4.1.318.1.1.14.3.3.1.5 | rARUStatusAruTemp1 | 0 | 0 | ARU temperature probe #1 reading. The summary exhaust temperature on 2nd generation ARUs. NOTE: -1 will be returned if the ARU is… |
1.3.6.1.4.1.318.1.1.14.3.3.1.6 | rARUStatusAruTemp2 | 0 | 0 | ARU temperature probe #2 reading. The exhaust temperature in the upper plenum on 2nd generation ARUs. NOTE: -1 will be returned i… |
1.3.6.1.4.1.318.1.1.14.3.3.1.7 | rARUStatusAruTemp3 | 0 | 0 | ARU temperature probe #3 reading. The exhaust temperature in the lower plenum on 2nd generation ARUs. NOTE: -1 will be returned i… |
1.3.6.1.4.1.318.1.1.14.3.3.1.8 | rARUStatusAruTempOvrdEnableDisable | 0 | 0 | This OID indicates whether the ARU remote temperature override is enabled or disabled. If this OID is a 1, the remote setting fo… |
1.3.6.1.4.1.318.1.1.14.3.3.1.9 | rARUStatusAruTempOvrdSetpoint | 0 | 0 | ARU remote temperature override setpoint setting. NOTE: -1 will be returned if the ARU is not communicating. Values are represent… |
1.3.6.1.4.1.318.1.1.14.3.3.1.11 | rARUStatusAruCommStatus | 0 | 0 | The state of communications to the device. commNeverDiscovered(1) indicates there has never been communications with this device… |
1.3.6.1.4.1.318.1.1.14.3.3.1.12 | rARUStatusAruTempOvrdStatus | 0 | 0 | Specifies whether the ARU is increasing airflow because exhaust air temperature has exceeded the setting specified in the rARUCon… |
1.3.6.1.4.1.318.1.1.14.3.3.1.13 | rARUStatusAruMasterControl | 0 | 0 | This is the master on/off control for the ARU. |
1.3.6.1.4.1.318.1.1.14.3.3.1.14 | rARUStatusAruTotalAirflow | 0 | 0 | The total airflow provided by the aru. Specified in cfm (cubic feet per minute). Can be converted to metric values using the con… |