This is the master on/off control for the ARU.
        
            
            Parsed from file powernet.mib.txt
            
            Company: None
            
            Module: PowerNet-MIB
        
        
This is the master on/off control for the ARU.
        
            
            Parsed from file PowerNet-MIB.mib
            
            Module: PowerNet-MIB
        
        
rARUStatusAruMasterControl OBJECT-TYPE SYNTAX INTEGER { aruOn (1), aruOff (2) } ACCESS read-only STATUS mandatory DESCRIPTION "This is the master on/off control for the ARU." ::= { rARUStatusEntry 13 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
rARUStatusAruMasterControl OBJECT-TYPE SYNTAX INTEGER { aruOn (1), aruOff (2) } ACCESS read-only STATUS mandatory DESCRIPTION "This is the master on/off control for the ARU." ::= { rARUStatusEntry 13 }
| OID | Name | Sub children | Sub Nodes Total | Description | 
|---|---|---|---|---|
| 1.3.6.1.4.1.318.1.1.14.3.3.1.1 | rARUStatusAruIndex | 0 | 0 | The index to the ARU entry. | 
| 1.3.6.1.4.1.318.1.1.14.3.3.1.2 | rARUStatusAruName | 0 | 0 | The name of the ARU. | 
| 1.3.6.1.4.1.318.1.1.14.3.3.1.3 | rARUStatusAruRemoteSetpoint | 0 | 0 | This OID defines the desired base airflow of the ARU, or the speed of the ARU fans when the temperature override is inactive. See…  | 
        
| 1.3.6.1.4.1.318.1.1.14.3.3.1.4 | rARUStatusAruManualSetpoint | 0 | 0 | Manual operating setpoint of the ARU, which is set on the panel of the ARU. If the ARU doesn't have a manual , the OID will alway…  | 
        
| 1.3.6.1.4.1.318.1.1.14.3.3.1.5 | rARUStatusAruTemp1 | 0 | 0 | ARU temperature probe #1 reading. The summary exhaust temperature on 2nd generation ARUs. NOTE: -1 will be returned if the ARU is…  | 
        
| 1.3.6.1.4.1.318.1.1.14.3.3.1.6 | rARUStatusAruTemp2 | 0 | 0 | ARU temperature probe #2 reading. The exhaust temperature in the upper plenum on 2nd generation ARUs. NOTE: -1 will be returned i…  | 
        
| 1.3.6.1.4.1.318.1.1.14.3.3.1.7 | rARUStatusAruTemp3 | 0 | 0 | ARU temperature probe #3 reading. The exhaust temperature in the lower plenum on 2nd generation ARUs. NOTE: -1 will be returned i…  | 
        
| 1.3.6.1.4.1.318.1.1.14.3.3.1.8 | rARUStatusAruTempOvrdEnableDisable | 0 | 0 | This OID indicates whether the ARU remote temperature override is enabled or disabled. If this OID is a 1, the remote setting fo…  | 
        
| 1.3.6.1.4.1.318.1.1.14.3.3.1.9 | rARUStatusAruTempOvrdSetpoint | 0 | 0 | ARU remote temperature override setpoint setting. NOTE: -1 will be returned if the ARU is not communicating. Values are represent…  | 
        
| 1.3.6.1.4.1.318.1.1.14.3.3.1.10 | rARUStatusAruAlarmState | 0 | 0 | An ASCII string containing the 8 flags representing the current alarm state of the ARU. If the state of the ARU is unknown, this …  | 
        
| 1.3.6.1.4.1.318.1.1.14.3.3.1.11 | rARUStatusAruCommStatus | 0 | 0 | The state of communications to the device. commNeverDiscovered(1) indicates there has never been communications with this device…  | 
        
| 1.3.6.1.4.1.318.1.1.14.3.3.1.12 | rARUStatusAruTempOvrdStatus | 0 | 0 | Specifies whether the ARU is increasing airflow because exhaust air temperature has exceeded the setting specified in the rARUCon…  | 
        
| 1.3.6.1.4.1.318.1.1.14.3.3.1.14 | rARUStatusAruTotalAirflow | 0 | 0 | The total airflow provided by the aru. Specified in cfm (cubic feet per minute). Can be converted to metric values using the con…  |