flowManagerCurrentRuleSet OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Index to the array of RuleSets. Specifies which set of
rules is the current one for this task. The meter will
be
unning the current RuleSet if this rows
flowManagerRunningStandby value is false(2).
When the manager sets this variable the meter will stop using
the tasks old current RuleSet and start using the new one.
Specifying RuleSet 0 (the empty set) stops flow measurement
for this task."
View at oid-info.com
Index to the array of RuleSets. Specifies which set of
rules is the 'current' one for this task. The meter will
be 'running' the current RuleSet if this row's
flowManagerRunningStandby value is false(2).
When the manager sets this variable the meter will stop using
the task's old current RuleSet and start using the new one.
Specifying RuleSet 0 (the empty set) stops flow measurement
for this task.
Parsed from file rfc2720-Traffic-Flow-Measurement---Meter.mib.txt
Company: None
Module: FLOW-METER-MIB
Index to the array of RuleSets. Specifies which set of
rules is the 'current' one for this task. The meter will
be 'running' the current RuleSet if this row's
flowManagerRunningStandby value is false(2).
When the manager sets this variable the meter will stop using
the task's old current RuleSet and start using the new one.
Specifying RuleSet 0 (the empty set) stops flow measurement
for this task.
Parsed from file FLOW-METER-MIB.mib
Module: FLOW-METER-MIB
Automatically extracted from RFC2720
flowManagerCurrentRuleSet OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Index to the array of RuleSets. Specifies which set of rules is the 'current' one for this task. The meter will be 'running' the current RuleSet if this row's flowManagerRunningStandby value is false(2). When the manager sets this variable the meter will stop using the task's old current RuleSet and start using the new one. Specifying RuleSet 0 (the empty set) stops flow measurement for this task." ::= { flowManagerInfoEntry 2 }
flowManagerCurrentRuleSet OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Index to the array of RuleSets. Specifies which set of rules is the 'current' one for this task. The meter will be 'running' the current RuleSet if this row's flowManagerRunningStandby value is false(2). When the manager sets this variable the meter will stop using the task's old current RuleSet and start using the new one. Specifying RuleSet 0 (the empty set) stops flow measurement for this task." ::= { flowManagerInfoEntry 2 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.40.1.4.1.1 | flowManagerIndex | 0 | 0 | An index which selects an entry in the flowManagerInfoTable. |
1.3.6.1.2.1.40.1.4.1.3 | flowManagerStandbyRuleSet | 0 | 0 | Index to the array of RuleSets. After reaching HighWaterMark (see below) the manager will switch to using the task's StandbyRule… |
1.3.6.1.2.1.40.1.4.1.4 | flowManagerHighWaterMark | 0 | 0 | A value expressed as a percentage, interpreted by the meter as an indication of how full the flow table should be before it shoul… |
1.3.6.1.2.1.40.1.4.1.5 | flowManagerCounterWrap | 0 | 0 | Specifies whether PDU and octet counters should wrap when they reach the top of their range (normal behaviour for Counter64 objec… |
1.3.6.1.2.1.40.1.4.1.6 | flowManagerOwner | 0 | 0 | Identifies the manager which created this row. |
1.3.6.1.2.1.40.1.4.1.7 | flowManagerTimeStamp | 0 | 0 | Time this row was last changed by its manager. |
1.3.6.1.2.1.40.1.4.1.8 | flowManagerStatus | 0 | 0 | The status of this row in the flowManagerInfoTable. A value of active(1) implies that this task may be activated, by setting its… |
1.3.6.1.2.1.40.1.4.1.9 | flowManagerRunningStandby | 0 | 0 | Set to true(1) by the meter to indicate that it has switched to runnning this task's StandbyRuleSet in place of its CurrentRuleSe… |