flowManagerStandbyRuleSet OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Index to the array of RuleSets. After reaching HighWaterMark
(see below) the manager will switch to using the tasks
StandbyRuleSet in place of its CurrentRuleSet. For this to be
effective the designated StandbyRuleSet should have a coarser
reporting granularity then the CurrentRuleSet. The manager may
also need to decrease the meter reading interval so that the
meter can recover flows measured by this tasks CurrentRuleSet."
DEFVAL { 0 } -- No standby
View at oid-info.com
Index to the array of RuleSets. After reaching HighWaterMark
(see below) the manager will switch to using the task's
StandbyRuleSet in place of its CurrentRuleSet. For this to be
effective the designated StandbyRuleSet should have a coarser
reporting granularity then the CurrentRuleSet. The manager may
also need to decrease the meter reading interval so that the
meter can recover flows measured by this task's CurrentRuleSet.
Parsed from file rfc2720-Traffic-Flow-Measurement---Meter.mib.txt
Company: None
Module: FLOW-METER-MIB
Index to the array of RuleSets. After reaching HighWaterMark
(see below) the manager will switch to using the task's
StandbyRuleSet in place of its CurrentRuleSet. For this to be
effective the designated StandbyRuleSet should have a coarser
reporting granularity then the CurrentRuleSet. The manager may
also need to decrease the meter reading interval so that the
meter can recover flows measured by this task's CurrentRuleSet.
Parsed from file FLOW-METER-MIB.mib
Module: FLOW-METER-MIB
Automatically extracted from RFC2720
flowManagerStandbyRuleSet OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Index to the array of RuleSets. After reaching HighWaterMark (see below) the manager will switch to using the task's StandbyRuleSet in place of its CurrentRuleSet. For this to be effective the designated StandbyRuleSet should have a coarser reporting granularity then the CurrentRuleSet. The manager may also need to decrease the meter reading interval so that the meter can recover flows measured by this task's CurrentRuleSet." DEFVAL { 0 } ::= { flowManagerInfoEntry 3 }
flowManagerStandbyRuleSet OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Index to the array of RuleSets. After reaching HighWaterMark (see below) the manager will switch to using the task's StandbyRuleSet in place of its CurrentRuleSet. For this to be effective the designated StandbyRuleSet should have a coarser reporting granularity then the CurrentRuleSet. The manager may also need to decrease the meter reading interval so that the meter can recover flows measured by this task's CurrentRuleSet." DEFVAL { 0 } ::= { flowManagerInfoEntry 3 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.40.1.4.1.1 | flowManagerIndex | 0 | 0 | An index which selects an entry in the flowManagerInfoTable. |
1.3.6.1.2.1.40.1.4.1.2 | flowManagerCurrentRuleSet | 0 | 0 | Index to the array of RuleSets. Specifies which set of rules is the 'current' one for this task. The meter will be 'running' th… |
1.3.6.1.2.1.40.1.4.1.4 | flowManagerHighWaterMark | 0 | 0 | A value expressed as a percentage, interpreted by the meter as an indication of how full the flow table should be before it shoul… |
1.3.6.1.2.1.40.1.4.1.5 | flowManagerCounterWrap | 0 | 0 | Specifies whether PDU and octet counters should wrap when they reach the top of their range (normal behaviour for Counter64 objec… |
1.3.6.1.2.1.40.1.4.1.6 | flowManagerOwner | 0 | 0 | Identifies the manager which created this row. |
1.3.6.1.2.1.40.1.4.1.7 | flowManagerTimeStamp | 0 | 0 | Time this row was last changed by its manager. |
1.3.6.1.2.1.40.1.4.1.8 | flowManagerStatus | 0 | 0 | The status of this row in the flowManagerInfoTable. A value of active(1) implies that this task may be activated, by setting its… |
1.3.6.1.2.1.40.1.4.1.9 | flowManagerRunningStandby | 0 | 0 | Set to true(1) by the meter to indicate that it has switched to runnning this task's StandbyRuleSet in place of its CurrentRuleSe… |