flowManagerCounterWrap OBJECT-TYPE
SYNTAX INTEGER { wrap(1), scale(2) }
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Specifies whether PDU and octet counters should wrap when
they reach the top of their range (normal behaviour for
Counter64 objects), or whether their scale factors should
be used instead. The combination of counter and scale
factor allows counts to be returned as non-negative binary
floating point numbers, with 64-bit mantissas and 8-bit
exponents."
DEFVAL { wrap }
View at oid-info.com
Specifies whether PDU and octet counters should wrap when
they reach the top of their range (normal behaviour for
Counter64 objects), or whether their scale factors should
be used instead. The combination of counter and scale
factor allows counts to be returned as non-negative binary
floating point numbers, with 64-bit mantissas and 8-bit
exponents.
Parsed from file rfc2720-Traffic-Flow-Measurement---Meter.mib.txt
Company: None
Module: FLOW-METER-MIB
Specifies whether PDU and octet counters should wrap when
they reach the top of their range (normal behaviour for
Counter64 objects), or whether their scale factors should
be used instead. The combination of counter and scale
factor allows counts to be returned as non-negative binary
floating point numbers, with 64-bit mantissas and 8-bit
exponents.
Parsed from file FLOW-METER-MIB.mib
Module: FLOW-METER-MIB
Automatically extracted from RFC2720
flowManagerCounterWrap OBJECT-TYPE SYNTAX INTEGER { wrap(1), scale(2) } MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Specifies whether PDU and octet counters should wrap when they reach the top of their range (normal behaviour for Counter64 objects), or whether their scale factors should be used instead. The combination of counter and scale factor allows counts to be returned as non-negative binary floating point numbers, with 64-bit mantissas and 8-bit exponents." DEFVAL { wrap } ::= { flowManagerInfoEntry 5 }
flowManagerCounterWrap OBJECT-TYPE SYNTAX INTEGER { wrap(1), scale(2) } MAX-ACCESS read-create STATUS deprecated DESCRIPTION "Specifies whether PDU and octet counters should wrap when they reach the top of their range (normal behaviour for Counter64 objects), or whether their scale factors should be used instead. The combination of counter and scale factor allows counts to be returned as non-negative binary floating point numbers, with 64-bit mantissas and 8-bit exponents." DEFVAL { wrap } ::= { flowManagerInfoEntry 5 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.40.1.4.1.1 | flowManagerIndex | 0 | 0 | An index which selects an entry in the flowManagerInfoTable. |
1.3.6.1.2.1.40.1.4.1.2 | flowManagerCurrentRuleSet | 0 | 0 | Index to the array of RuleSets. Specifies which set of rules is the 'current' one for this task. The meter will be 'running' th… |
1.3.6.1.2.1.40.1.4.1.3 | flowManagerStandbyRuleSet | 0 | 0 | Index to the array of RuleSets. After reaching HighWaterMark (see below) the manager will switch to using the task's StandbyRule… |
1.3.6.1.2.1.40.1.4.1.4 | flowManagerHighWaterMark | 0 | 0 | A value expressed as a percentage, interpreted by the meter as an indication of how full the flow table should be before it shoul… |
1.3.6.1.2.1.40.1.4.1.6 | flowManagerOwner | 0 | 0 | Identifies the manager which created this row. |
1.3.6.1.2.1.40.1.4.1.7 | flowManagerTimeStamp | 0 | 0 | Time this row was last changed by its manager. |
1.3.6.1.2.1.40.1.4.1.8 | flowManagerStatus | 0 | 0 | The status of this row in the flowManagerInfoTable. A value of active(1) implies that this task may be activated, by setting its… |
1.3.6.1.2.1.40.1.4.1.9 | flowManagerRunningStandby | 0 | 0 | Set to true(1) by the meter to indicate that it has switched to runnning this task's StandbyRuleSet in place of its CurrentRuleSe… |