flowManagerStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this row in the flowManagerInfoTable. A value
of active(1) implies that this task may be activated, by
setting its CurrentRuleSet and StandbyRuleSet variables.
Its HighWaterMark and RunningStandby variables may also be
changed."
View at oid-info.com
The status of this row in the flowManagerInfoTable. A value
of active(1) implies that this task may be activated, by
setting its CurrentRuleSet and StandbyRuleSet variables.
Its HighWaterMark and RunningStandby variables may also be
changed.
Parsed from file rfc2720-Traffic-Flow-Measurement---Meter.mib.txt
Company: None
Module: FLOW-METER-MIB
The status of this row in the flowManagerInfoTable. A value
of active(1) implies that this task may be activated, by
setting its CurrentRuleSet and StandbyRuleSet variables.
Its HighWaterMark and RunningStandby variables may also be
changed.
Parsed from file FLOW-METER-MIB.mib
Module: FLOW-METER-MIB
Automatically extracted from RFC2720
flowManagerStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this row in the flowManagerInfoTable. A value of active(1) implies that this task may be activated, by setting its CurrentRuleSet and StandbyRuleSet variables. Its HighWaterMark and RunningStandby variables may also be changed." ::= { flowManagerInfoEntry 8 }
flowManagerStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this row in the flowManagerInfoTable. A value of active(1) implies that this task may be activated, by setting its CurrentRuleSet and StandbyRuleSet variables. Its HighWaterMark and RunningStandby variables may also be changed." ::= { flowManagerInfoEntry 8 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.40.1.4.1.1 | flowManagerIndex | 0 | 0 | An index which selects an entry in the flowManagerInfoTable. |
1.3.6.1.2.1.40.1.4.1.2 | flowManagerCurrentRuleSet | 0 | 0 | Index to the array of RuleSets. Specifies which set of rules is the 'current' one for this task. The meter will be 'running' th… |
1.3.6.1.2.1.40.1.4.1.3 | flowManagerStandbyRuleSet | 0 | 0 | Index to the array of RuleSets. After reaching HighWaterMark (see below) the manager will switch to using the task's StandbyRule… |
1.3.6.1.2.1.40.1.4.1.4 | flowManagerHighWaterMark | 0 | 0 | A value expressed as a percentage, interpreted by the meter as an indication of how full the flow table should be before it shoul… |
1.3.6.1.2.1.40.1.4.1.5 | flowManagerCounterWrap | 0 | 0 | Specifies whether PDU and octet counters should wrap when they reach the top of their range (normal behaviour for Counter64 objec… |
1.3.6.1.2.1.40.1.4.1.6 | flowManagerOwner | 0 | 0 | Identifies the manager which created this row. |
1.3.6.1.2.1.40.1.4.1.7 | flowManagerTimeStamp | 0 | 0 | Time this row was last changed by its manager. |
1.3.6.1.2.1.40.1.4.1.9 | flowManagerRunningStandby | 0 | 0 | Set to true(1) by the meter to indicate that it has switched to runnning this task's StandbyRuleSet in place of its CurrentRuleSe… |