OID reference

dsx1LoopbackConfig

1.3.6.1.3.2.6.1.9

Description

This variable represents the desired loopback configuration of the DS1 interface. Agents supporting read/write access should return inconsistentValue in response to a requested loopback state that the interface does not support. The values mean: dsx1NoLoop Not in the loopback state. A device that is not capable of per…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.3.2.6.1 (dsx1ConfigEntry)
Node code
9
Node name
dsx1LoopbackConfig
Numeric OID
1.3.6.1.3.2.6.1.9
URN notation
urn:oid:1.3.6.1.3.2.6.1.9
Type
OBJECT-TYPE
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 3 2 6 1 9}

  • {iso(1) identified-organization(3) dod(6) internet(1) experimental(3) t1Carrier(2) dsx1ConfigTable(6) dsx1ConfigEntry(1) dsx1LoopbackConfig(9)}
  • {iso(1) identified-organization(3) dod(6) internet(1) experimental(3) ds1(2) dsx1ConfigTable(6) dsx1ConfigEntry(1) dsx1LoopbackConfig(9)}
  • {iso(1) org(3) dod(6) internet(1) experimental(3) t1Carrier(2) dsx1ConfigTable(6) dsx1ConfigEntry(1) dsx1LoopbackConfig(9)}
  • {iso(1) org(3) dod(6) internet(1) experimental(3) ds1(2) dsx1ConfigTable(6) dsx1ConfigEntry(1) dsx1LoopbackConfig(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) experimental(3) t1Carrier(2) dsx1ConfigTable(6) dsx1ConfigEntry(1) dsx1LoopbackConfig(9)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) experimental(3) ds1(2) dsx1ConfigTable(6) dsx1ConfigEntry(1) dsx1LoopbackConfig(9)}
  • {iso(1) iso-organization(3) dod(6) internet(1) experimental(3) t1Carrier(2) dsx1ConfigTable(6) dsx1ConfigEntry(1) dsx1LoopbackConfig(9)}
  • {iso(1) iso-organization(3) dod(6) internet(1) experimental(3) ds1(2) dsx1ConfigTable(6) dsx1ConfigEntry(1) dsx1LoopbackConfig(9)}
OID-IRI notation
  • /1/3/6/1/3/2/6/1/9
  • /ISO/Identified-Organization/6/1/3/2/6/1/9
  • /ISO/3/6/1/3/2/6/1/9
Named path variants
  • /iso/identified-organization/dod/internet/experimental/t1Carrier/dsx1ConfigTable/dsx1ConfigEntry/dsx1LoopbackConfig
  • /iso/identified-organization/dod/internet/experimental/ds1/dsx1ConfigTable/dsx1ConfigEntry/dsx1LoopbackConfig
  • /iso/identified-organization/dod/internet/experimental/T1-Carrier/dsx1ConfigTable/dsx1ConfigEntry/dsx1LoopbackConfig
  • /iso/org/dod/internet/experimental/t1Carrier/dsx1ConfigTable/dsx1ConfigEntry/dsx1LoopbackConfig
  • /iso/org/dod/internet/experimental/ds1/dsx1ConfigTable/dsx1ConfigEntry/dsx1LoopbackConfig
  • /iso/org/dod/internet/experimental/T1-Carrier/dsx1ConfigTable/dsx1ConfigEntry/dsx1LoopbackConfig
  • /iso/iso-identified-organization/dod/internet/experimental/t1Carrier/dsx1ConfigTable/dsx1ConfigEntry/dsx1LoopbackConfig
  • /iso/iso-identified-organization/dod/internet/experimental/ds1/dsx1ConfigTable/dsx1ConfigEntry/dsx1LoopbackConfig
  • /iso/iso-identified-organization/dod/internet/experimental/T1-Carrier/dsx1ConfigTable/dsx1ConfigEntry/dsx1LoopbackConfig
  • /iso/iso-organization/dod/internet/experimental/t1Carrier/dsx1ConfigTable/dsx1ConfigEntry/dsx1LoopbackConfig
  • /iso/iso-organization/dod/internet/experimental/ds1/dsx1ConfigTable/dsx1ConfigEntry/dsx1LoopbackConfig
  • /iso/iso-organization/dod/internet/experimental/T1-Carrier/dsx1ConfigTable/dsx1ConfigEntry/dsx1LoopbackConfig

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

This variable represents the desired loopback
configuration of the DS1 interface. Agents
supporting read/write access should return
inconsistentValue in response to a requested
loopback state that the interface does not
support. The values mean:

dsx1NoLoop
Not in the loopback state. A device that is not
capable of performing a loopback on the interface
shall always return this as its value.

dsx1PayloadLoop
The received signal at this interface is looped
through the device. Typically the received signal
is looped back for retransmission after it has
passed through the device's framing function.

dsx1LineLoop
The received signal at this interface does not go
through the device (minimum penetration) but is
looped back out.

dsx1OtherLoop
Loopbacks that are not defined here.

dsx1InwardLoop
The transmitted signal at this interface is
looped back and received by the same interface.
What is transmitted onto the line is product
dependent.

dsx1DualLoop
Both dsx1LineLoop and dsx1InwardLoop will be
active simultaneously.
Sources for this description

MIBdepot

Parsed from DS1-MIB.txt · riverstone · DS1-MIB

Historical records

Additional source information

Information from MIBdepot
dsx1LoopbackConfig OBJECT-TYPE
          SYNTAX  INTEGER {
                      dsx1NoLoop(1),
                      dsx1PayloadLoop(2),
                      dsx1LineLoop(3),
                      dsx1OtherLoop(4),


                      dsx1InwardLoop(5),
                      dsx1DualLoop(6)
                    }
          MAX-ACCESS  read-write
          STATUS  current
          DESCRIPTION
                 "This variable represents the desired loopback
                 configuration of the DS1 interface.  Agents
                 supporting read/write access should return
                 inconsistentValue in response to a requested
                 loopback state that the interface does not
                 support.  The values mean:

                 dsx1NoLoop
                  Not in the loopback state.  A device that is not
                 capable of performing a loopback on the interface
                 shall always return this as its value.

                 dsx1PayloadLoop
                  The received signal at this interface is looped
                 through the device.  Typically the received signal
                 is looped back for retransmission after it has
                 passed through the device's framing function.

                 dsx1LineLoop
                  The received signal at this interface does not go
                 through the device (minimum penetration) but is
                 looped back out.

                 dsx1OtherLoop
                  Loopbacks that are not defined here.

                 dsx1InwardLoop
                  The transmitted signal at this interface is
                 looped back and received by the same interface.
                 What is transmitted onto the line is product
                 dependent.

                 dsx1DualLoop
                  Both dsx1LineLoop and dsx1InwardLoop will be
                 active simultaneously."
          ::= { dsx1ConfigEntry 9 }

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6)

Defense Communication Agency

Current Registration Authority (inferred from ancestor 1.3.6.1.3)

Internet Assigned Numbers Authority

Siblings (23)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.3.2.6.1.1 dsx1LineIndex00 This object should be made equal to ifIndex. The
next paragraph describes its previous usage.
Making the object equal to ifIndex…
1.3.6.1.3.2.6.1.2 dsx1IfIndex00 This value for this object is equal to the value
of ifIndex from the Interfaces table of MIB II
(RFC 1213).
1.3.6.1.3.2.6.1.3 dsx1TimeElapsed00 The number of seconds that have elapsed since
the beginning of the near end current error-
measurement period. If, for some reas…
1.3.6.1.3.2.6.1.4 dsx1ValidIntervals00 The number of previous near end intervals for
which data was collected. The value will be
96 unless the interface was brought on…
1.3.6.1.3.2.6.1.5 dsx1LineType00 This variable indicates the variety of DS1
Line implementing this circuit. The type of
circuit affects the number of bits…
1.3.6.1.3.2.6.1.6 dsx1LineCoding00 This variable describes the variety of Zero Code


Suppression used on this interface, which in turn
affects a number of its charac…
1.3.6.1.3.2.6.1.7 dsx1SendCode00 This variable indicates what type of code is
being sent across the DS1 interface by the device.
Setting this variable causes the …
1.3.6.1.3.2.6.1.8 dsx1CircuitIdentifier00 This variable contains the transmission vendor's
circuit identifier, for the purpose of
facilitating troubleshooting.
1.3.6.1.3.2.6.1.10 dsx1LineStatus00 This variable indicates the Line Status of the
interface. It contains loopback, failure,
received 'alarm' and transmitted 'alarm…
1.3.6.1.3.2.6.1.11 dsx1SignalMode00 'none' indicates that no bits are reserved for
signaling on this channel.

'robbedBit' indicates that DS1 Robbed Bit Sig-
naling i…
1.3.6.1.3.2.6.1.12 dsx1TransmitClockSource00 The source of Transmit Clock.
'loopTiming' indicates that the recovered re-
ceive clock is used as the transmit clock.

'localTimin…
1.3.6.1.3.2.6.1.13 dsx1Fdl00 This bitmap describes the use of the facili-
ties data link, and is the sum of the capabili-
ties. Set any bits that are appro…
1.3.6.1.3.2.6.1.14 dsx1InvalidIntervals00 The number of intervals in the range from 0 to
dsx1ValidIntervals for which no data is
available. This object will typically be …
1.3.6.1.3.2.6.1.15 dsx1LineLength00 The length of the ds1 line in meters. This
objects provides information for line build out
circuitry. This object is only useful…
1.3.6.1.3.2.6.1.16 dsx1LineStatusLastChange00 The value of MIB II's sysUpTime object at the
time this DS1 entered its current line status
state. If the current state was ente…
1.3.6.1.3.2.6.1.17 dsx1LineStatusChangeTrapEnable00 Indicates whether dsx1LineStatusChange traps
should be generated for this interface.
1.3.6.1.3.2.6.1.18 dsx1LoopbackStatus00 This variable represents the current state of the
loopback on the DS1 interface. It contains
information about loopbacks establi…
1.3.6.1.3.2.6.1.19 dsx1Ds1ChannelNumber00 This variable represents the channel number of


the DS1/E1 on its parent Ds2/E2 or DS3/E3. A
value of 0 indicated this DS1/E1 doe…
1.3.6.1.3.2.6.1.20 dsx1Channelization00 Indicates whether this ds1/e1 is channelized or
unchannelized. The value of enabledDs0 indicates
that this is a DS1 channelized …
1.3.6.1.3.2.6.1.21 dsx1LineMode00 This setting puts the T1 framer into either
long-haul (CSU) mode or short-haul (DSU) mode.
1.3.6.1.3.2.6.1.23 dsx1LineImpedance00 Nominal line impedance. For T1 and J1 lines, the
value is typically balanced100ohms(3). For E1
lines, the value is typically un…
1.3.6.1.3.2.6.1.100 dsx1LineBuildOut00 This variable represents the line build out in dB.
1.3.6.1.3.2.6.1.101 dsx1PerformanceReport00 If the value is ds1Mib, then statistics are kept for
this interface.