OID reference

recConfigEntry

1.3.6.1.4.1.1206.4.1.1.7.9.7.1

Description

<Definition>This object defines an entry in the recording configuration table. <Superseded by> NTCIP1201-RecMechV2.recMechV2FactoryEntry & COND-TRIGGER-MIB.fdCondTriggerEntry (ISO 20684-3) <Informative> The replacement trigger table has two indicies: an owner and a name. The replacement recording factory table has thr…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.1.1.7.9.7 (recConfigTable)
Node code
1
Node name
recConfigEntry
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.1.1.7.9.7.1
URN notation
urn:oid:1.3.6.1.4.1.1206.4.1.1.7.9.7.1
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 1 1 7 9 7 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) protocols(1) layers(1) application(7) recMech(9) recConfigTable(7) recConfigEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) protocols(1) layers(1) application(7) recMech(9) recConfigTable(7) recConfigEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) protocols(1) layers(1) application(7) recMech(9) recConfigTable(7) recConfigEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) protocols(1) layers(1) application(7) recMech(9) recConfigTable(7) recConfigEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) protocols(1) layers(1) application(7) recMech(9) recConfigTable(7) recConfigEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) protocols(1) layers(1) application(7) recMech(9) recConfigTable(7) recConfigEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) protocols(1) layers(1) application(7) recMech(9) recConfigTable(7) recConfigEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) protocols(1) layers(1) application(7) recMech(9) recConfigTable(7) recConfigEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) protocols(1) layers(1) application(7) recMech(9) recConfigTable(7) recConfigEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) protocols(1) layers(1) application(7) recMech(9) recConfigTable(7) recConfigEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) protocols(1) layers(1) application(7) recMech(9) recConfigTable(7) recConfigEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) protocols(1) layers(1) application(7) recMech(9) recConfigTable(7) recConfigEntry(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) protocols(1) layers(1) application(7) recMech(9) recConfigTable(7) recConfigEntry(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) protocols(1) layers(1) application(7) recMech(9) recConfigTable(7) recConfigEntry(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) protocols(1) layers(1) application(7) recMech(9) recConfigTable(7) recConfigEntry(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) protocols(1) layers(1) application(7) recMech(9) recConfigTable(7) recConfigEntry(1)}
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/1/1/7/9/7/1
  • /ISO/Identified-Organization/6/1/4/1/1206/4/1/1/7/9/7/1
  • /ISO/3/6/1/4/1/1206/4/1/1/7/9/7/1
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/protocols/layers/application/recMech/recConfigTable/recConfigEntry
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/Protocols/layers/application/recMech/recConfigTable/recConfigEntry
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/protocols/layers/application/recMech/recConfigTable/recConfigEntry
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/Protocols/layers/application/recMech/recConfigTable/recConfigEntry
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/protocols/layers/application/recMech/recConfigTable/recConfigEntry
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/Protocols/layers/application/recMech/recConfigTable/recConfigEntry
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/protocols/layers/application/recMech/recConfigTable/recConfigEntry
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/Protocols/layers/application/recMech/recConfigTable/recConfigEntry
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/protocols/layers/application/recMech/recConfigTable/recConfigEntry
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/Protocols/layers/application/recMech/recConfigTable/recConfigEntry
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/protocols/layers/application/recMech/recConfigTable/recConfigEntry
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/Protocols/layers/application/recMech/recConfigTable/recConfigEntry
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/protocols/layers/application/recMech/recConfigTable/recConfigEntry
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/Protocols/layers/application/recMech/recConfigTable/recConfigEntry
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/protocols/layers/application/recMech/recConfigTable/recConfigEntry
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/Protocols/layers/application/recMech/recConfigTable/recConfigEntry
  • Additional combinations skipped.

SNMP properties

Value type
RecConfigEntry
Maximum access defined by MIB
not-accessible
Status in MIB
deprecated, mandatory

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — ITE public NTCIP working repository MIBs, NTCIP published standard MIB annexes (reviewed modules)

Value type
RecConfigEntry
Maximum access defined by MIB
not-accessible
Status in MIB
deprecated

Variant 2 — NTCIP published standard MIB annexes (reviewed modules)

Value type
RecConfigEntry
Maximum access defined by MIB
not-accessible
Status in MIB
mandatory

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 3 distinct definitions; some records may not include a definition.

Show 3 published definitions

recConfigEntry · deprecated

recConfigEntry  OBJECT-TYPE
  SYNTAX      RecConfigEntry
  MAX-ACCESS  not-accessible
  STATUS      deprecated
  DESCRIPTION
    "<Definition>This object defines an entry in the recording configuration 
      table. 
    <Superseded by> NTCIP1201-RecMechV2.recMechV2FactoryEntry & 
      COND-TRIGGER-MIB.fdCondTriggerEntry (ISO 20684-3)
    <Informative> The replacement trigger table has two indicies: an owner 
      and a name. The replacement recording factory table has three 
      indicies, an owner, the class name, and the factory name. 
      In addition to the other changes described, the trigger table 
      adds the following columns:
        - a textual description of the trigger
        - an indication whether the comparison is based on the current 
          object value or a delta from its previous reading
        - an octet-based comparison value since SNMPv3 discourages the use of 
          Opaque
        - a wildcard that allows defining the same condition on 
          multiple comparison OIDs (e.g., all rows of a table)
        - indications of the target and context of the comparison object; 
          in other words, the comparison can be performed by a proxy agent
          or can reference another device to get the object value to compare 
          against
        - the frequency at which the comparison is made
        - a truthDuration that allows the configuration to require the 
          evaluation to be true for some length of time prior to firing the 
          trigger.
        - startup states that define whether the triggers startup in a fired 
          or unfired state (for hysteresis, there are two startups)
        - a pointer to the action table that identifies the action(s) to be
          performed.
        - an error message object that allows a device to report 
          configuration errors.
        - counters for the number of times the trigger has fired, had 
          evaluation errors, and activation errors.
        - an indication of the type of storage to use 
        - a RowStatus object.
        The recMech factory table adds the following columns:
        - the security data used to activate the row and that will be used
          to retrieve values for the recording
        - object contexts, which allows a proxy/hrbrid agent to capture 
          information from another context
        - A StorageType object 
    <Object Identifier> 1.3.6.1.4.1.1206.4.1.1.7.9.7.1"
   INDEX { recConfigID }
::= { recConfigTable 1 }

recConfigEntry · deprecated

recConfigEntry OBJECT-TYPE
SYNTAX      RecConfigEntry
MAX-ACCESS not-accessible
STATUS      deprecated
DESCRIPTION
  "<Definition>This object defines an entry in the recording configuration
  table.
  <Supplanted by> ISO26048-1-Recording.fdRecordingFactoryEntry & ISO26048-1-
  CondTrigger.fdCondTriggerEntry (ISO 26048-1)
  <Informative> The replacement trigger table has two indicies: an owner and
  a name. The replacement recording factory table has three indicies, an
  owner, the class name, and the factory name.
  In addition to the other changes described, the trigger table adds the
  following columns:
  - a textual description of the trigger
  - an indication whether the comparison is based on the current object value
  or a delta from its previous reading
  - an octet-based comparison value since SNMPv3 discourages the use of
  Opaque
  - a wildcard that allows defining the same condition on multiple comparison
  OIDs (e.g., all rows of a table)
  - indications of the target and context of the comparison object; in other
  words, the comparison can be performed by a proxy agent or can reference
  another device to get the object value to compare against
  - the frequency at which the comparison is made
  - a truthDuration that allows the configuration to require the evaluation


                                                                                    

                                                                                       
                                                                                      

  to be true for some length of time prior to firing the trigger.
  - startup states that define whether the triggers startup in a fired or
  unfired state (for hysteresis, there are two startups)
  - a pointer to the action table that identifies the action(s) to be
  performed.
  - an error message object that allows a device to report configuration
  errors.
  - counters for the number of times the trigger has fired, had evaluation
  errors, and activation errors.
  - an indication of the type of storage to use
  - a RowStatus object. The recMech factory table adds the following columns:
  - the security data used to activate the row and that will be used to
  retrieve values for the recording
  - object contexts, which allows a proxy/hrbrid agent to capture information
  from another context
  - A StorageType object
  <Object Identifier> 1.3.6.1.4.1.1206.4.1.1.7.9.7.1"
INDEX      { recConfigID }
::= { recConfigTable 1 }

recConfigEntry · mandatory

recConfigEntry OBJECT-TYPE
   SYNTAX RecConfigEntry
   ACCESS not-accessible
   STATUS mandatory
   DESCRIPTION
      "<Definition>This object defines an entry in the recording
         configuration table.
        <Object Identifier> 1.3.6.1.4.1.1206.4.1.1.7.9.7.1
      "
   INDEX { recConfigID }
::= { recConfigTable 1 }

Meaning

Descriptions

3 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

<Definition>This object defines an entry in the recording configuration table. <Superseded by> NTCIP1201-RecMechV2.recMechV2FactoryEntry & COND-TRIGGER-MIB.fdCondTriggerEntry (ISO 20684-3) <Informative> The replacement trigger table has two indicies: an owner and a name. The replacement recording factory table has three indicies, an owner, the class name, and the factory name. In addition to the other changes described, the trigger table adds the following columns: - a textual description of the trigger - an indication whether the comparison is based on the current object value or a delta from its previous reading - an octet-based comparison value since SNMPv3 discourages the use of Opaque - a wildcard that allows defining the same condition on multiple comparison OIDs (e.g., all rows of a table) - indications of the target and context of the comparison object; in other words, the comparison can be performed by a proxy agent or can reference another device to get the object value to compare against - the frequency at which the comparison is made - a truthDuration that allows the configuration to require the evaluation to be true for some length of time prior to firing the trigger. - startup states that define whether the triggers startup in a fired or unfired state (for hysteresis, there are two startups) - a pointer to the action table that identifies the action(s) to be performed. - an error message object that allows a device to report configuration errors. - counters for the number of times the trigger has fired, had evaluation errors, and activation errors. - an indication of the type of storage to use - a RowStatus object. The recMech factory table adds the following columns: - the security data used to activate the row and that will be used to retrieve values for the recording - object contexts, which allows a proxy/hrbrid agent to capture information from another context - A StorageType object <Object Identifier> 1.3.6.1.4.1.1206.4.1.1.7.9.7.1

Sources for this description

ITE public NTCIP working repository MIBs

See 1 matching source record

Description 2

<Definition>This object defines an entry in the recording configuration table. <Supplanted by> ISO26048-1-Recording.fdRecordingFactoryEntry & ISO26048-1- CondTrigger.fdCondTriggerEntry (ISO 26048-1) <Informative> The replacement trigger table has two indicies: an owner and a name. The replacement recording factory table has three indicies, an owner, the class name, and the factory name. In addition to the other changes described, the trigger table adds the following columns: - a textual description of the trigger - an indication whether the comparison is based on the current object value or a delta from its previous reading - an octet-based comparison value since SNMPv3 discourages the use of Opaque - a wildcard that allows defining the same condition on multiple comparison OIDs (e.g., all rows of a table) - indications of the target and context of the comparison object; in other words, the comparison can be performed by a proxy agent or can reference another device to get the object value to compare against - the frequency at which the comparison is made - a truthDuration that allows the configuration to require the evaluation to be true for some length of time prior to firing the trigger. - startup states that define whether the triggers startup in a fired or unfired state (for hysteresis, there are two startups) - a pointer to the action table that identifies the action(s) to be performed. - an error message object that allows a device to report configuration errors. - counters for the number of times the trigger has fired, had evaluation errors, and activation errors. - an indication of the type of storage to use - a RowStatus object. The recMech factory table adds the following columns: - the security data used to activate the row and that will be used to retrieve values for the recording - object contexts, which allows a proxy/hrbrid agent to capture information from another context - A StorageType object <Object Identifier> 1.3.6.1.4.1.1206.4.1.1.7.9.7.1

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 3

<Definition>This object defines an entry in the recording configuration table. <Object Identifier> 1.3.6.1.4.1.1206.4.1.1.7.9.7.1

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

3 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1ITE public NTCIP working repository MIBs1 record · 2 sources

Description 1

recConfigEntry · deprecatedITE public NTCIP working repository MIBs2 sources

Status in source: deprecated.

Names: recConfigEntry

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "recConfigEntry",
    "OBJECT-TYPE",
    "SYNTAX",
    "RecConfigEntry",
    "MAX-ACCESS",
    "not-accessible",
    "STATUS",
    "deprecated",
    "DESCRIPTION",
    "\"<Definition>This object defines an entry in the recording configuration table. <Superseded by> NTCIP1201-RecMechV2.recMechV2FactoryEntry & COND-TRIGGER-MIB.fdCondTriggerEntry (ISO 20684-3) <Informative> The replacement trigger table has two indicies: an owner and a name. The replacement recording factory table has three indicies, an owner, the class name, and the factory name. In addition to the other changes described, the trigger table adds the following columns: - a textual description of the trigger - an indication whether the comparison is based on the current object value or a delta from its previous reading - an octet-based comparison value since SNMPv3 discourages the use of Opaque - a wildcard that allows defining the same condition on multiple comparison OIDs (e.g., all rows of a table) - indications of the target and context of the comparison object; in other words, the comparison can be performed by a proxy agent or can reference another device to get the object value to compare against - the frequency at which the comparison is made - a truthDuration that allows the configuration to require the evaluation to be true for some length of time prior to firing the trigger. - startup states that define whether the triggers startup in a fired or unfired state (for hysteresis, there are two startups) - a pointer to the action table that identifies the action(s) to be performed. - an error message object that allows a device to report configuration errors. - counters for the number of times the trigger has fired, had evaluation errors, and activation errors. - an indication of the type of storage to use - a RowStatus object. The recMech factory table adds the following columns: - the security data used to activate the row and that will be used to retrieve values for the recording - object contexts, which allows a proxy/hrbrid agent to capture information from another context - A StorageType object <Object Identifier> 1.3.6.1.4.1.1206.4.1.1.7.9.7.1\"",
    "INDEX",
    "{",
    "recConfigID",
    "}",
    "::=",
    "{",
    "recConfigTable",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "RecConfigEntry"
    ],
    null,
    [
      "MaxAccessPart",
      "not-accessible"
    ],
    [
      "Status",
      "deprecated"
    ],
    [
      "DESCRIPTION",
      "<Definition>This object defines an entry in the recording configuration table. <Superseded by> NTCIP1201-RecMechV2.recMechV2FactoryEntry & COND-TRIGGER-MIB.fdCondTriggerEntry (ISO 20684-3) <Informative> The replacement trigger table has two indicies: an owner and a name. The replacement recording factory table has three indicies, an owner, the class name, and the factory name. In addition to the other changes described, the trigger table adds the following columns: - a textual description of the trigger - an indication whether the comparison is based on the current object value or a delta from its previous reading - an octet-based comparison value since SNMPv3 discourages the use of Opaque - a wildcard that allows defining the same condition on multiple comparison OIDs (e.g., all rows of a table) - indications of the target and context of the comparison object; in other words, the comparison can be performed by a proxy agent or can reference another device to get the object value to compare against - the frequency at which the comparison is made - a truthDuration that allows the configuration to require the evaluation to be true for some length of time prior to firing the trigger. - startup states that define whether the triggers startup in a fired or unfired state (for hysteresis, there are two startups) - a pointer to the action table that identifies the action(s) to be performed. - an error message object that allows a device to report configuration errors. - counters for the number of times the trigger has fired, had evaluation errors, and activation errors. - an indication of the type of storage to use - a RowStatus object. The recMech factory table adds the following columns: - the security data used to activate the row and that will be used to retrieve values for the recording - object contexts, which allows a proxy/hrbrid agent to capture information from another context - A StorageType object <Object Identifier> 1.3.6.1.4.1.1206.4.1.1.7.9.7.1"
    ],
    null,
    null,
    [
      "INDEX",
      [
        [
          0,
          "recConfigID"
        ]
      ]
    ],
    null
  ]
}
Records for description 2NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 2

recConfigEntry · deprecatedNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: deprecated.

Names: recConfigEntry

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "recConfigEntry",
    "OBJECT-TYPE",
    "SYNTAX",
    "RecConfigEntry",
    "MAX-ACCESS",
    "not-accessible",
    "STATUS",
    "deprecated",
    "DESCRIPTION",
    "\"<Definition>This object defines an entry in the recording configuration table. <Supplanted by> ISO26048-1-Recording.fdRecordingFactoryEntry & ISO26048-1- CondTrigger.fdCondTriggerEntry (ISO 26048-1) <Informative> The replacement trigger table has two indicies: an owner and a name. The replacement recording factory table has three indicies, an owner, the class name, and the factory name. In addition to the other changes described, the trigger table adds the following columns: - a textual description of the trigger - an indication whether the comparison is based on the current object value or a delta from its previous reading - an octet-based comparison value since SNMPv3 discourages the use of Opaque - a wildcard that allows defining the same condition on multiple comparison OIDs (e.g., all rows of a table) - indications of the target and context of the comparison object; in other words, the comparison can be performed by a proxy agent or can reference another device to get the object value to compare against - the frequency at which the comparison is made - a truthDuration that allows the configuration to require the evaluation to be true for some length of time prior to firing the trigger. - startup states that define whether the triggers startup in a fired or unfired state (for hysteresis, there are two startups) - a pointer to the action table that identifies the action(s) to be performed. - an error message object that allows a device to report configuration errors. - counters for the number of times the trigger has fired, had evaluation errors, and activation errors. - an indication of the type of storage to use - a RowStatus object. The recMech factory table adds the following columns: - the security data used to activate the row and that will be used to retrieve values for the recording - object contexts, which allows a proxy/hrbrid agent to capture information from another context - A StorageType object <Object Identifier> 1.3.6.1.4.1.1206.4.1.1.7.9.7.1\"",
    "INDEX",
    "{",
    "recConfigID",
    "}",
    "::=",
    "{",
    "recConfigTable",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "RecConfigEntry"
    ],
    null,
    [
      "MaxAccessPart",
      "not-accessible"
    ],
    [
      "Status",
      "deprecated"
    ],
    [
      "DESCRIPTION",
      "<Definition>This object defines an entry in the recording configuration table. <Supplanted by> ISO26048-1-Recording.fdRecordingFactoryEntry & ISO26048-1- CondTrigger.fdCondTriggerEntry (ISO 26048-1) <Informative> The replacement trigger table has two indicies: an owner and a name. The replacement recording factory table has three indicies, an owner, the class name, and the factory name. In addition to the other changes described, the trigger table adds the following columns: - a textual description of the trigger - an indication whether the comparison is based on the current object value or a delta from its previous reading - an octet-based comparison value since SNMPv3 discourages the use of Opaque - a wildcard that allows defining the same condition on multiple comparison OIDs (e.g., all rows of a table) - indications of the target and context of the comparison object; in other words, the comparison can be performed by a proxy agent or can reference another device to get the object value to compare against - the frequency at which the comparison is made - a truthDuration that allows the configuration to require the evaluation to be true for some length of time prior to firing the trigger. - startup states that define whether the triggers startup in a fired or unfired state (for hysteresis, there are two startups) - a pointer to the action table that identifies the action(s) to be performed. - an error message object that allows a device to report configuration errors. - counters for the number of times the trigger has fired, had evaluation errors, and activation errors. - an indication of the type of storage to use - a RowStatus object. The recMech factory table adds the following columns: - the security data used to activate the row and that will be used to retrieve values for the recording - object contexts, which allows a proxy/hrbrid agent to capture information from another context - A StorageType object <Object Identifier> 1.3.6.1.4.1.1206.4.1.1.7.9.7.1"
    ],
    null,
    null,
    [
      "INDEX",
      [
        [
          0,
          "recConfigID"
        ]
      ]
    ],
    null
  ]
}
Records for description 3NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 3

recConfigEntry · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: recConfigEntry

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "recConfigEntry",
    "OBJECT-TYPE",
    "SYNTAX",
    "RecConfigEntry",
    "ACCESS",
    "not-accessible",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition>This object defines an entry in the recording configuration table. <Object Identifier> 1.3.6.1.4.1.1206.4.1.1.7.9.7.1 \"",
    "INDEX",
    "{",
    "recConfigID",
    "}",
    "::=",
    "{",
    "recConfigTable",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "RecConfigEntry"
    ],
    null,
    [
      "MaxAccessPart",
      "not-accessible"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition>This object defines an entry in the recording configuration table. <Object Identifier> 1.3.6.1.4.1.1206.4.1.1.7.9.7.1"
    ],
    null,
    null,
    [
      "INDEX",
      [
        [
          0,
          "recConfigID"
        ]
      ]
    ],
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Direct children (13)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.1.1.7.9.7.1.1 recConfigID00
1.3.6.1.4.1.1206.4.1.1.7.9.7.1.2 recConfigClass00
1.3.6.1.4.1.1206.4.1.1.7.9.7.1.3 recConfigMode00
1.3.6.1.4.1.1206.4.1.1.7.9.7.1.4 recConfigCompareValue00
1.3.6.1.4.1.1206.4.1.1.7.9.7.1.5 recConfigCompareValue200
1.3.6.1.4.1.1206.4.1.1.7.9.7.1.6 recConfigCompareOID00
1.3.6.1.4.1.1206.4.1.1.7.9.7.1.7 recConfigRecordOID00
1.3.6.1.4.1.1206.4.1.1.7.9.7.1.8 recConfigTriggerPoint00
1.3.6.1.4.1.1206.4.1.1.7.9.7.1.9 recConfigSamplePeriod00
1.3.6.1.4.1.1206.4.1.1.7.9.7.1.10 recConfigSampleOID00
1.3.6.1.4.1.1206.4.1.1.7.9.7.1.11 recConfigNumEntries00
1.3.6.1.4.1.1206.4.1.1.7.9.7.1.12 recConfigAction00
1.3.6.1.4.1.1206.4.1.1.7.9.7.1.13 recConfigStatus00