This variable determines the input side flow control, if any.
The value v35InFlowNone specifies no flow control. The
value v35InFlowTxClk specifies that flow control is achieved
using a 'gapped' TX clock. The values v35InFlowDcd and
v35InFlowCts specify using the DCD and CTS lines,
respectively, for flow control. Finally, v35InFlowBoth
specifies using both DCD and CTS for flow control.
Parsed from file CP300.mib.txt
Company: marconi
Module: AAC3-MIB
Vendor: ADC Kentrox
Module: AAC3-MIB (aac3-140.mib)
Type: TABULAR
Access: read-write
Syntax: INTEGER
Automatically extracted from www.mibdepot.com
v35InFlowCntl OBJECT-TYPE SYNTAX INTEGER { v35InFlowNone(1), v35InFlowTxClk(2), v35InFlowDcd(3), v35InFlowCts(4), v35InFlowBoth(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable determines the input side flow control, if any. The value v35InFlowNone specifies no flow control. The value v35InFlowTxClk specifies that flow control is achieved using a 'gapped' TX clock. The values v35InFlowDcd and v35InFlowCts specify using the DCD and CTS lines, respectively, for flow control. Finally, v35InFlowBoth specifies using both DCD and CTS for flow control." ::= { v35ConfigEntry 7 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.181.1.13.6.4.1.1.1 | v35PortIndex | 0 | 0 | This variable uniquely identifies the V.35/EIA-530 port for which this table entry applies. It has the same value as the portInd… |
1.3.6.1.4.1.181.1.13.6.4.1.1.2 | v35IfSelect | 0 | 0 | The value of this variable selects the interface mode for the port. The value v35SelectV35 selects V.35 mode, while the value v3… |
1.3.6.1.4.1.181.1.13.6.4.1.1.3 | v35LosDetect | 0 | 0 | The value of this variable determines which signal, if any, causes an LOS condition when deasserted. The behavior of the system … |
1.3.6.1.4.1.181.1.13.6.4.1.1.4 | v35ClkRate | 0 | 0 | This variable sets the V.35/EIA-530 interface clock rate when the interface sources the clock. When the interface clock is loope… |
1.3.6.1.4.1.181.1.13.6.4.1.1.5 | v35ClkSrc | 0 | 0 | This variable controls the source of clocks on the V.35/EIA-530 interface. The 'v35ClkNotLooped' option selects the local AAC-3 c… |
1.3.6.1.4.1.181.1.13.6.4.1.1.6 | v35Loopback | 0 | 0 | This variable controls loop back configuration of the V.35/ EIA-530 interface. The value v35NoLoopback disables loopbacks. The … |
1.3.6.1.4.1.181.1.13.6.4.1.1.8 | v35OutFlowCntl | 0 | 0 | This variable determines the output side flow control, if any. The value v35OutFlowNone specifies no flow control. The values v… |
1.3.6.1.4.1.181.1.13.6.4.1.1.9 | v35Status | 0 | 0 | This variable indicates the alarm status of the V.35/EIA-530 interface. The v35Status is a bit map represented as a sum, therefor… |
1.3.6.1.4.1.181.1.13.6.4.1.1.10 | v35InClockPolarity | 0 | 0 | This variable controls the polarity of the clock used to time incoming data on the V.35/EIA 530 port. The value v35InClkNormal(1… |