This variable determines the output side flow control, if
any. The value v35OutFlowNone specifies no flow control. The
values v35OutFlowDtr and v35OutFlowRts specify using the DTR
and RTS lines, respectively, for flow control, for which the
specified line being deasserted inhibits transmission. The
value v35OutFlowEither specifies that either DTR or RTS being
deasserted inhibits transmission. The value v35OutFlowBoth
specifies that both DTR and RTS must be deasserted to stop
transmission.
Parsed from file CP300.mib.txt
Company: marconi
Module: AAC3-MIB
Vendor: ADC Kentrox
Module: AAC3-MIB (aac3-140.mib)
Type: TABULAR
Access: read-write
Syntax: INTEGER
Automatically extracted from www.mibdepot.com
v35OutFlowCntl OBJECT-TYPE SYNTAX INTEGER { v35OutFlowNone(1), v35OutFlowDtr(2), v35OutFlowRts(3), v35OutFlowEither(4), v35OutFlowBoth(5) } ACCESS read-write STATUS mandatory DESCRIPTION "This variable determines the output side flow control, if any. The value v35OutFlowNone specifies no flow control. The values v35OutFlowDtr and v35OutFlowRts specify using the DTR and RTS lines, respectively, for flow control, for which the specified line being deasserted inhibits transmission. The value v35OutFlowEither specifies that either DTR or RTS being deasserted inhibits transmission. The value v35OutFlowBoth specifies that both DTR and RTS must be deasserted to stop transmission." ::= { v35ConfigEntry 8 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.181.1.13.6.4.1.1.1 | v35PortIndex | 0 | 0 | This variable uniquely identifies the V.35/EIA-530 port for which this table entry applies. It has the same value as the portInd… |
1.3.6.1.4.1.181.1.13.6.4.1.1.2 | v35IfSelect | 0 | 0 | The value of this variable selects the interface mode for the port. The value v35SelectV35 selects V.35 mode, while the value v3… |
1.3.6.1.4.1.181.1.13.6.4.1.1.3 | v35LosDetect | 0 | 0 | The value of this variable determines which signal, if any, causes an LOS condition when deasserted. The behavior of the system … |
1.3.6.1.4.1.181.1.13.6.4.1.1.4 | v35ClkRate | 0 | 0 | This variable sets the V.35/EIA-530 interface clock rate when the interface sources the clock. When the interface clock is loope… |
1.3.6.1.4.1.181.1.13.6.4.1.1.5 | v35ClkSrc | 0 | 0 | This variable controls the source of clocks on the V.35/EIA-530 interface. The 'v35ClkNotLooped' option selects the local AAC-3 c… |
1.3.6.1.4.1.181.1.13.6.4.1.1.6 | v35Loopback | 0 | 0 | This variable controls loop back configuration of the V.35/ EIA-530 interface. The value v35NoLoopback disables loopbacks. The … |
1.3.6.1.4.1.181.1.13.6.4.1.1.7 | v35InFlowCntl | 0 | 0 | This variable determines the input side flow control, if any. The value v35InFlowNone specifies no flow control. The value v35In… |
1.3.6.1.4.1.181.1.13.6.4.1.1.9 | v35Status | 0 | 0 | This variable indicates the alarm status of the V.35/EIA-530 interface. The v35Status is a bit map represented as a sum, therefor… |
1.3.6.1.4.1.181.1.13.6.4.1.1.10 | v35InClockPolarity | 0 | 0 | This variable controls the polarity of the clock used to time incoming data on the V.35/EIA 530 port. The value v35InClkNormal(1… |