This variable indicates the alarm status of the V.35/EIA-530
interface.
The v35Status is a bit map represented as a sum, therefore, it
can represent multiple failures (alarms) simultaneously.
v35NoAlarm should be set if and only if no other flag is set.
The various bit positions are:
1 v35NoAlarm No alarm present.
2 v35Los Loss of signal detected.
4 v35DteLineLoopback DTE Line Loopback.
8 v35LocalLoopback Local Loopback.
16 v35LossOfClock Loss of Clock detected.
Parsed from file CP300.mib.txt
Company: marconi
Module: AAC3-MIB
Vendor: ADC Kentrox
Module: AAC3-MIB (aac3-140.mib)
Type: TABULAR
Access: read-only
Syntax: INTEGER
Automatically extracted from www.mibdepot.com
v35Status OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This variable indicates the alarm status of the V.35/EIA-530 interface. The v35Status is a bit map represented as a sum, therefore, it can represent multiple failures (alarms) simultaneously. v35NoAlarm should be set if and only if no other flag is set. The various bit positions are: 1 v35NoAlarm No alarm present. 2 v35Los Loss of signal detected. 4 v35DteLineLoopback DTE Line Loopback. 8 v35LocalLoopback Local Loopback. 16 v35LossOfClock Loss of Clock detected." ::= { v35ConfigEntry 9 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.181.1.13.6.4.1.1.1 | v35PortIndex | 0 | 0 | This variable uniquely identifies the V.35/EIA-530 port for which this table entry applies. It has the same value as the portInd… |
1.3.6.1.4.1.181.1.13.6.4.1.1.2 | v35IfSelect | 0 | 0 | The value of this variable selects the interface mode for the port. The value v35SelectV35 selects V.35 mode, while the value v3… |
1.3.6.1.4.1.181.1.13.6.4.1.1.3 | v35LosDetect | 0 | 0 | The value of this variable determines which signal, if any, causes an LOS condition when deasserted. The behavior of the system … |
1.3.6.1.4.1.181.1.13.6.4.1.1.4 | v35ClkRate | 0 | 0 | This variable sets the V.35/EIA-530 interface clock rate when the interface sources the clock. When the interface clock is loope… |
1.3.6.1.4.1.181.1.13.6.4.1.1.5 | v35ClkSrc | 0 | 0 | This variable controls the source of clocks on the V.35/EIA-530 interface. The 'v35ClkNotLooped' option selects the local AAC-3 c… |
1.3.6.1.4.1.181.1.13.6.4.1.1.6 | v35Loopback | 0 | 0 | This variable controls loop back configuration of the V.35/ EIA-530 interface. The value v35NoLoopback disables loopbacks. The … |
1.3.6.1.4.1.181.1.13.6.4.1.1.7 | v35InFlowCntl | 0 | 0 | This variable determines the input side flow control, if any. The value v35InFlowNone specifies no flow control. The value v35In… |
1.3.6.1.4.1.181.1.13.6.4.1.1.8 | v35OutFlowCntl | 0 | 0 | This variable determines the output side flow control, if any. The value v35OutFlowNone specifies no flow control. The values v… |
1.3.6.1.4.1.181.1.13.6.4.1.1.10 | v35InClockPolarity | 0 | 0 | This variable controls the polarity of the clock used to time incoming data on the V.35/EIA 530 port. The value v35InClkNormal(1… |