adminSerialIPAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address currently in use by the LANtern
network monitor on the serial channel.
adminSerialIPAddr may be written at any time;
however, the change does not take effect until the
LANtern network monitor is restarted. When
adminSerialIPAddr is read, it returns the IP
address currently in use, regardless of any
previous writes.
adminSerialIPAddr is stored in nonvolatile RAM."
DEFVAL { c044cd81H } -- 192.68.205.129
View at oid-info.com
The IP address currently in use by the LANtern
network monitor on the serial channel.
adminSerialIPAddr may be written at any time;
however, the change does not take effect until the
LANtern network monitor is restarted. When
adminSerialIPAddr is read, it returns the IP
address currently in use, regardless of any
previous writes.
adminSerialIPAddr is stored in nonvolatile RAM.
Parsed from file LANTERN.MIB.txt
Company: None
Module: Novell-LANtern-MIB
The IP address currently in use by the LANtern
network monitor on the serial channel.
adminSerialIPAddr may be written at any time;
however, the change does not take effect until the
LANtern network monitor is restarted. When
adminSerialIPAddr is read, it returns the IP
address currently in use, regardless of any
previous writes.
adminSerialIPAddr is stored in nonvolatile RAM.
Parsed from file Novell-LANtern-Admin-MIB.mib
Module: Novell-LANtern-Admin-MIB
Automatically extracted from Nwlanz2.mib
adminSerialIPAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address currently in use by the LANtern network monitor on the serial channel. adminSerialIPAddr may be written at any time; however, the change does not take effect until the LANtern network monitor is restarted. When adminSerialIPAddr is read, it returns the IP address currently in use, regardless of any previous writes. adminSerialIPAddr is stored in nonvolatile RAM." DEFVAL { 'c044cd81'H } ::= { lanternAdmin 21 }
adminSerialIPAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The IP address currently in use by the LANtern network monitor on the serial channel. adminSerialIPAddr may be written at any time; however, the change does not take effect until the LANtern network monitor is restarted. When adminSerialIPAddr is read, it returns the IP address currently in use, regardless of any previous writes. adminSerialIPAddr is stored in nonvolatile RAM." DEFVAL { 'c044cd81'H } ::= { lanternAdmin 21 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.23.2.1.1.21.0 | adminSerialIPAddr | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.23.2.1.1.1 | adminIdentification | 1 | 1 | An identifying ASCII string may be attached to the LANtern network monitor by writing adminIdentification. Conversely, the LANte… |
1.3.6.1.4.1.23.2.1.1.2 | adminDateAndTime | 1 | 1 | Reading adminDateAndTime returns the current date and time in use by the LANtern network monitor. The LANtern network monitor's d… |
1.3.6.1.4.1.23.2.1.1.3 | adminTimeZone | 1 | 1 | A DisplayString defining the time zone of the LANtern network monitor. adminTimeZone is neither parsed nor used by the LANtern n… |
1.3.6.1.4.1.23.2.1.1.4 | adminPowerOnTime | 1 | 1 | The date and time when the LANtern network monitor was last powered on or restarted. |
1.3.6.1.4.1.23.2.1.1.5 | adminPowerOffTime | 1 | 1 | The date and time when the LANtern network monitor was last powered off or restarted. The value is 0 (midnight, 1 January 1900) … |
1.3.6.1.4.1.23.2.1.1.6 | adminNetworkDataLink | 1 | 1 | The type of data link encapsulation to be used on the monitored network. adminNetworkDataLink may be written at any time; howeve… |
1.3.6.1.4.1.23.2.1.1.7 | adminNetworkIPAddr | 1 | 1 | The IP address to be used by the LANtern network monitor on the monitored network. adminNetworkIPAddr may be written at any time;… |
1.3.6.1.4.1.23.2.1.1.8 | adminNetworkSubnetMask | 1 | 1 | The subnet mask for the monitored network. adminNetworkSubnetMask may be written at any time; however, the change does not take e… |
1.3.6.1.4.1.23.2.1.1.9 | adminNetworkGateway | 1 | 1 | The IP address of a gateway directly connected to the monitored network (the LANtern network monitor's default gateway). adminNe… |
1.3.6.1.4.1.23.2.1.1.10 | adminClientTable | 1 | 5 | A table providing data on all authorized LANtern clients. The table is accessed by adminClientIPAddr. A new entry may be create… |
1.3.6.1.4.1.23.2.1.1.11 | adminUnauthorizedIPAddr | 1 | 1 | The IP address of the station that generated the authentication failure. |
1.3.6.1.4.1.23.2.1.1.12 | adminUnauthorizedCommunity | 1 | 1 | The community name string used in the PDU that generated the authentication failure. |
1.3.6.1.4.1.23.2.1.1.13 | adminNotificationTable | 1 | 9 | A list of all stations wishing to receive traps from the LANtern network monitor; accessed by adminNotificationIPAddr. A new ent… |
1.3.6.1.4.1.23.2.1.1.14 | adminTrapHandle | 1 | 1 | A unique handle that is generated for each trap issued and that is passed in the trap-PDU along with any other variable bindings. |
1.3.6.1.4.1.23.2.1.1.15 | adminTrapAcknowledge | 1 | 1 | A trap is acknowledged by writing the value of adminTrapHandle passed in the trap-PDU to adminTrapAcknowledge. |
1.3.6.1.4.1.23.2.1.1.16 | adminDownLoadFile | 1 | 1 | The name of the executable file to be downloaded from adminDownLoadServer. |
1.3.6.1.4.1.23.2.1.1.17 | adminDownLoadServer | 1 | 1 | The name of the file server from which to download a new executable image (adminDownLoadFile). |
1.3.6.1.4.1.23.2.1.1.18 | adminDownload | 1 | 1 | A write to adminDownload of temporaryChange(1) or permanentChange(2) causes the LANtern network monitor to discontinue its normal… |
1.3.6.1.4.1.23.2.1.1.19 | adminReset | 1 | 1 | A write to adminReset causes the LANtern network monitor to discontinue its normal functions and commence a restart sequence. Th… |
1.3.6.1.4.1.23.2.1.1.20 | adminSerialDataLink | 1 | 1 | The type of data link encapsulation to be used on the serial line. adminSerialDataLink may be written at any time; however, the … |
1.3.6.1.4.1.23.2.1.1.22 | adminSerialSubnetMask | 1 | 1 | The subnet mask for the serial channel. adminSerialSubnetMask may be written at any time; however, the change does not take effec… |
1.3.6.1.4.1.23.2.1.1.23 | adminSerialBaudRate | 1 | 1 | A codification of the baud rate to be used on the serial line for incoming calls or when the line is directly connected. Change … |
1.3.6.1.4.1.23.2.1.1.24 | adminSerialTimeout | 1 | 1 | Once a phone connection has been established, the LANtern network monitor maintains that connection until either the other end ha… |
1.3.6.1.4.1.23.2.1.1.25 | adminSerialConnection | 1 | 1 | The type of connection used by the serial line. adminSerialConnection may be written at any time; however, the change does not ta… |
1.3.6.1.4.1.23.2.1.1.26 | adminSerialFlowControl | 1 | 1 | The type of flow control used on the serial line. adminSerialFlowControl may be written at any time; however, the change does not… |
1.3.6.1.4.1.23.2.1.1.27 | adminModemControl | 1 | 1 | A delimited string containing commands to initialize, dial, and hang up the modem. See Section 3.1.2 for more details on the for… |
1.3.6.1.4.1.23.2.1.1.28 | adminModemConnect | 1 | 1 | A delimited string containing baud rates and modem responses when it connects at particular baud rates. See Section 3.1.2 for mo… |
1.3.6.1.4.1.23.2.1.1.29 | adminModemNoConnect | 1 | 1 | A delimited string containing baud rates and modem responses when it connects at particular baud rates. See Section 3 for more de… |
1.3.6.1.4.1.23.2.1.1.30 | adminGatewayControl | 1 | 1 | A switch to enable or disable IP gatewaying between the serial line and the network. See Section 3 for more details on the format… |
1.3.6.1.4.1.23.2.1.1.31 | adminPhoneTable | 1 | 7 | A table that provides information about each possible phone connection that can be made over the serial channel. The table is ac… |
1.3.6.1.4.1.23.2.1.1.32 | adminFCBControl | 1 | 1 | A switch to disable the packet capture feature. To enable this flag (after disabling it) a cool start must apply to the LANtern i… |