Reference record for OID 1.3.6.1.4.1.232.141.2.3.1.1.10



parent
1.3.6.1.4.1.232.141.2.3.1.1 (cpqCrLogDrvEntry)
node code
10
node name
cpqCrLogDrvCondition
dot oid
1.3.6.1.4.1.232.141.2.3.1.1.10
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrLogDrv(3) cpqCrLogDrvTable(1) cpqCrLogDrvEntry(1) cpqCrLogDrvCondition(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrLogDrv(3) cpqCrLogDrvTable(1) cpqCrLogDrvEntry(1) cpqCrLogDrvCondition(10)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrLogDrv(3) cpqCrLogDrvTable(1) cpqCrLogDrvEntry(1) cpqCrLogDrvCondition(10)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrLogDrv(3) cpqCrLogDrvTable(1) cpqCrLogDrvEntry(1) cpqCrLogDrvCondition(10)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrLogDrv(3) cpqCrLogDrvTable(1) cpqCrLogDrvEntry(1) cpqCrLogDrvCondition(10)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrLogDrv(3) cpqCrLogDrvTable(1) cpqCrLogDrvEntry(1) cpqCrLogDrvCondition(10)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrLogDrv(3) cpqCrLogDrvTable(1) cpqCrLogDrvEntry(1) cpqCrLogDrvCondition(10)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrLogDrv(3) cpqCrLogDrvTable(1) cpqCrLogDrvEntry(1) cpqCrLogDrvCondition(10)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqClusteredRAID/cpqCrComponent/cpqCrLogDrv/cpqCrLogDrvTable/cpqCrLogDrvEntry/cpqCrLogDrvCondition
  • /iso/identified-organization/dod/internet/private/enterprise/hp/cpqClusteredRAID/cpqCrComponent/cpqCrLogDrv/cpqCrLogDrvTable/cpqCrLogDrvEntry/cpqCrLogDrvCondition
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/compaq/cpqClusteredRAID/cpqCrComponent/cpqCrLogDrv/cpqCrLogDrvTable/cpqCrLogDrvEntry/cpqCrLogDrvCondition
  • /iso/org/dod/internet/private/enterprise/hp/cpqClusteredRAID/cpqCrComponent/cpqCrLogDrv/cpqCrLogDrvTable/cpqCrLogDrvEntry/cpqCrLogDrvCondition
  • /iso/org/dod/internet/private/enterprises/compaq/cpqClusteredRAID/cpqCrComponent/cpqCrLogDrv/cpqCrLogDrvTable/cpqCrLogDrvEntry/cpqCrLogDrvCondition
  • /iso/org/dod/internet/private/enterprises/hp/cpqClusteredRAID/cpqCrComponent/cpqCrLogDrv/cpqCrLogDrvTable/cpqCrLogDrvEntry/cpqCrLogDrvCondition
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/compaq/cpqClusteredRAID/cpqCrComponent/cpqCrLogDrv/cpqCrLogDrvTable/cpqCrLogDrvEntry/cpqCrLogDrvCondition
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqClusteredRAID/cpqCrComponent/cpqCrLogDrv/cpqCrLogDrvTable/cpqCrLogDrvEntry/cpqCrLogDrvCondition
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/232/141/2/3/1/1/10

    Description by mibdepot

    RAIDset condition.

    This value represents the overall condition of this RAIDset
    and any associated physical drives.

    Parsed from file CPQCR1.MIB.txt
    Company: None
    Module: CPQCR-MIB

    Description by circitor

    RAIDset condition.

    This value represents the overall condition of this RAIDset
    and any associated physical drives.

    Parsed from file CPQCR-MIB.mib
    Module: CPQCR-MIB

    Information by mibdepot

    cpqCrLogDrvCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "RAIDset condition. This value represents the overall condition of this RAIDset and any associated physical drives." ::= { cpqCrLogDrvEntry 10 }

    Information by oid_info

    Vendor: Compaq
    Module: CPQCR-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    cpqCrLogDrvCondition OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), degraded(3), failed(4) } ACCESS read-only STATUS mandatory DESCRIPTION "RAIDset condition. This value represents the overall condition of this RAIDset and any associated physical drives." ::= { cpqCrLogDrvEntry 10 }

    Brothers (9)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.232.141.2.3.1.1.1 cpqCrLogDrvCntlrIndex 0 0 Clustered RAID RAIDset Controller Index.

    This maps the RAIDsets into their respective controllers.
    Controller index 'i' under the…
    1.3.6.1.4.1.232.141.2.3.1.1.2 cpqCrLogDrvIndex 0 0 Clustered RAID RAIDset Index.

    This logical drive number keeps track of multiple instances of
    logical drives which are on the same…
    1.3.6.1.4.1.232.141.2.3.1.1.3 cpqCrLogDrvRAIDLevel 0 0 RAID Level.

    This shows the RAID level of the RAIDset.
    To change the RAID level, run the CL1850 Array
    Configuration Utility.

    The fol…
    1.3.6.1.4.1.232.141.2.3.1.1.4 cpqCrLogDrvStatus 0 0 RAIDset Status.

    The RAIDset can be in one of the following states:

    Good (2)
    Indicates that the RAIDset is fully operational.

    Reduce…
    1.3.6.1.4.1.232.141.2.3.1.1.5 cpqCrLogDrvRebuildPercentage 0 0 RAIDset Rebuild Percentage Complete.

    After a failed physical drive has been replaced, the physical
    drive must have its data rebui…
    1.3.6.1.4.1.232.141.2.3.1.1.7 cpqCrLogDrvAvailSpares 0 0 RAIDset Available Spares.

    This indicates if this RAIDset has one or more spares
    designated for it that are not currently in use b…
    1.3.6.1.4.1.232.141.2.3.1.1.8 cpqCrLogDrvSize 0 0 RAIDset Size.

    This is the size of the RAIDset in megabytes. This value
    is calculated using the value 1,048,576 (2^20) as a megab…
    1.3.6.1.4.1.232.141.2.3.1.1.9 cpqCrLogDrvPhyDrvIDs 0 0 RAIDset Physical Drive IDs.

    This lists the physical drive IDs which are associated with this
    RAIDset. These are the same IDs whic…
    1.3.6.1.4.1.232.141.2.3.1.1.11 cpqCrLogDrvPartitionIDs 0 0 RAIDset Logical Drive IDs.

    This lists the logical drive IDs which are associated with this
    RAIDset. These are the same IDs which …