Reference record for OID 1.3.6.1.4.1.232.141.2.3.1.1.4



parent
1.3.6.1.4.1.232.141.2.3.1.1 (cpqCrLogDrvEntry)
node code
4
node name
cpqCrLogDrvStatus
dot oid
1.3.6.1.4.1.232.141.2.3.1.1.4
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrLogDrv(3) cpqCrLogDrvTable(1) cpqCrLogDrvEntry(1) cpqCrLogDrvStatus(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrLogDrv(3) cpqCrLogDrvTable(1) cpqCrLogDrvEntry(1) cpqCrLogDrvStatus(4)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrLogDrv(3) cpqCrLogDrvTable(1) cpqCrLogDrvEntry(1) cpqCrLogDrvStatus(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrLogDrv(3) cpqCrLogDrvTable(1) cpqCrLogDrvEntry(1) cpqCrLogDrvStatus(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrLogDrv(3) cpqCrLogDrvTable(1) cpqCrLogDrvEntry(1) cpqCrLogDrvStatus(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrLogDrv(3) cpqCrLogDrvTable(1) cpqCrLogDrvEntry(1) cpqCrLogDrvStatus(4)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrLogDrv(3) cpqCrLogDrvTable(1) cpqCrLogDrvEntry(1) cpqCrLogDrvStatus(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqClusteredRAID(141) cpqCrComponent(2) cpqCrLogDrv(3) cpqCrLogDrvTable(1) cpqCrLogDrvEntry(1) cpqCrLogDrvStatus(4)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqClusteredRAID/cpqCrComponent/cpqCrLogDrv/cpqCrLogDrvTable/cpqCrLogDrvEntry/cpqCrLogDrvStatus
  • /iso/identified-organization/dod/internet/private/enterprise/hp/cpqClusteredRAID/cpqCrComponent/cpqCrLogDrv/cpqCrLogDrvTable/cpqCrLogDrvEntry/cpqCrLogDrvStatus
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/compaq/cpqClusteredRAID/cpqCrComponent/cpqCrLogDrv/cpqCrLogDrvTable/cpqCrLogDrvEntry/cpqCrLogDrvStatus
  • /iso/org/dod/internet/private/enterprise/hp/cpqClusteredRAID/cpqCrComponent/cpqCrLogDrv/cpqCrLogDrvTable/cpqCrLogDrvEntry/cpqCrLogDrvStatus
  • /iso/org/dod/internet/private/enterprises/compaq/cpqClusteredRAID/cpqCrComponent/cpqCrLogDrv/cpqCrLogDrvTable/cpqCrLogDrvEntry/cpqCrLogDrvStatus
  • /iso/org/dod/internet/private/enterprises/hp/cpqClusteredRAID/cpqCrComponent/cpqCrLogDrv/cpqCrLogDrvTable/cpqCrLogDrvEntry/cpqCrLogDrvStatus
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/compaq/cpqClusteredRAID/cpqCrComponent/cpqCrLogDrv/cpqCrLogDrvTable/cpqCrLogDrvEntry/cpqCrLogDrvStatus
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqClusteredRAID/cpqCrComponent/cpqCrLogDrv/cpqCrLogDrvTable/cpqCrLogDrvEntry/cpqCrLogDrvStatus
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/232/141/2/3/1/1/4

    Description by mibdepot

    RAIDset Status.

    The RAIDset can be in one of the following states:

    Good (2)
    Indicates that the RAIDset is fully operational.

    Reduced (3)
    Indicates that the RAIDset is operating in a degraded or
    reduced state. One or more of the physical disks which make
    up the RAIDset are either missing or failed, but the
    RAIDset can continue to operate without data loss.

    Failed (4)
    Indicates that the RAIDset is not operational.

    Reconstructing (5)
    Indicates that the RAIDset is regenerating a failed
    physical drive's data onto a replacement drive that is part
    of the RAIDset.

    All user data remains available during the reconstruction
    process, but some performance reduction may occur when a
    request requires access to the device being reconstructed.

    Initializing (6)
    Indicates that the controller is writing its file structure
    onto the RAIDset's member devices.

    Parsed from file CPQCR1.MIB.txt
    Company: None
    Module: CPQCR-MIB

    Description by circitor

    RAIDset Status.

    The RAIDset can be in one of the following states:

    Good (2)
    Indicates that the RAIDset is fully operational.

    Reduced (3)
    Indicates that the RAIDset is operating in a degraded or
    reduced state. One or more of the physical disks which make
    up the RAIDset are either missing or failed, but the
    RAIDset can continue to operate without data loss.

    Failed (4)
    Indicates that the RAIDset is not operational.

    Reconstructing (5)
    Indicates that the RAIDset is regenerating a failed
    physical drive's data onto a replacement drive that is part
    of the RAIDset.

    All user data remains available during the reconstruction
    process, but some performance reduction may occur when a
    request requires access to the device being reconstructed.

    Initializing (6)
    Indicates that the controller is writing its file structure
    onto the RAIDset's member devices.

    Parsed from file CPQCR-MIB.mib
    Module: CPQCR-MIB

    Information by mibdepot

    cpqCrLogDrvStatus OBJECT-TYPE SYNTAX INTEGER { other(1), good(2), reduced(3), failed(4), reconstructing(5), initializing(6) } ACCESS read-only STATUS mandatory DESCRIPTION "RAIDset Status. The RAIDset can be in one of the following states: Good (2) Indicates that the RAIDset is fully operational. Reduced (3) Indicates that the RAIDset is operating in a degraded or reduced state. One or more of the physical disks which make up the RAIDset are either missing or failed, but the RAIDset can continue to operate without data loss. Failed (4) Indicates that the RAIDset is not operational. Reconstructing (5) Indicates that the RAIDset is regenerating a failed physical drive's data onto a replacement drive that is part of the RAIDset. All user data remains available during the reconstruction process, but some performance reduction may occur when a request requires access to the device being reconstructed. Initializing (6) Indicates that the controller is writing its file structure onto the RAIDset's member devices." ::= { cpqCrLogDrvEntry 4 }

    Information by oid_info

    Vendor: Compaq
    Module: CPQCR-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    cpqCrLogDrvStatus OBJECT-TYPE SYNTAX INTEGER { other(1), good(2), reduced(3), failed(4), reconstructing(5), initializing(6) } ACCESS read-only STATUS mandatory DESCRIPTION "RAIDset Status. The RAIDset can be in one of the following states: Good (2) Indicates that the RAIDset is fully operational. Reduced (3) Indicates that the RAIDset is operating in a degraded or reduced state. One or more of the physical disks which make up the RAIDset are either missing or failed, but the RAIDset can continue to operate without data loss. Failed (4) Indicates that the RAIDset is not operational. Reconstructing (5) Indicates that the RAIDset is regenerating a failed physical drive's data onto a replacement drive that is part of the RAIDset. All user data remains available during the reconstruction process, but some performance reduction may occur when a request requires access to the device being reconstructed. Initializing (6) Indicates that the controller is writing its file structure onto the RAIDset's member devices." ::= { cpqCrLogDrvEntry 4 }

    Brothers (9)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.232.141.2.3.1.1.1 cpqCrLogDrvCntlrIndex 0 0 Clustered RAID RAIDset Controller Index.

    This maps the RAIDsets into their respective controllers.
    Controller index 'i' under the…
    1.3.6.1.4.1.232.141.2.3.1.1.2 cpqCrLogDrvIndex 0 0 Clustered RAID RAIDset Index.

    This logical drive number keeps track of multiple instances of
    logical drives which are on the same…
    1.3.6.1.4.1.232.141.2.3.1.1.3 cpqCrLogDrvRAIDLevel 0 0 RAID Level.

    This shows the RAID level of the RAIDset.
    To change the RAID level, run the CL1850 Array
    Configuration Utility.

    The fol…
    1.3.6.1.4.1.232.141.2.3.1.1.5 cpqCrLogDrvRebuildPercentage 0 0 RAIDset Rebuild Percentage Complete.

    After a failed physical drive has been replaced, the physical
    drive must have its data rebui…
    1.3.6.1.4.1.232.141.2.3.1.1.7 cpqCrLogDrvAvailSpares 0 0 RAIDset Available Spares.

    This indicates if this RAIDset has one or more spares
    designated for it that are not currently in use b…
    1.3.6.1.4.1.232.141.2.3.1.1.8 cpqCrLogDrvSize 0 0 RAIDset Size.

    This is the size of the RAIDset in megabytes. This value
    is calculated using the value 1,048,576 (2^20) as a megab…
    1.3.6.1.4.1.232.141.2.3.1.1.9 cpqCrLogDrvPhyDrvIDs 0 0 RAIDset Physical Drive IDs.

    This lists the physical drive IDs which are associated with this
    RAIDset. These are the same IDs whic…
    1.3.6.1.4.1.232.141.2.3.1.1.10 cpqCrLogDrvCondition 0 0 RAIDset condition.

    This value represents the overall condition of this RAIDset
    and any associated physical drives.
    1.3.6.1.4.1.232.141.2.3.1.1.11 cpqCrLogDrvPartitionIDs 0 0 RAIDset Logical Drive IDs.

    This lists the logical drive IDs which are associated with this
    RAIDset. These are the same IDs which …