RAIDset Available Spares.
This indicates if this RAIDset has one or more spares
designated for it that are not currently in use by another drive.
Each octet present will be a physical drive ID that is an
available spare for this logical drive. These are the same ID's
which can be used as indexes into the physical drive table.
An octet string of length zero indicates that there are no
available spares for this logical drive.
Parsed from file CPQCR1.MIB.txt
Company: None
Module: CPQCR-MIB
RAIDset Available Spares.
This indicates if this RAIDset has one or more spares
designated for it that are not currently in use by another drive.
Each octet present will be a physical drive ID that is an
available spare for this logical drive. These are the same ID's
which can be used as indexes into the physical drive table.
An octet string of length zero indicates that there are no
available spares for this logical drive.
Parsed from file CPQCR-MIB.mib
Module: CPQCR-MIB
cpqCrLogDrvAvailSpares OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "RAIDset Available Spares. This indicates if this RAIDset has one or more spares designated for it that are not currently in use by another drive. Each octet present will be a physical drive ID that is an available spare for this logical drive. These are the same ID's which can be used as indexes into the physical drive table. An octet string of length zero indicates that there are no available spares for this logical drive." ::= { cpqCrLogDrvEntry 7 }
Vendor: Compaq
Module: CPQCR-MIB
[Automatically extracted from oidview.com]
cpqCrLogDrvAvailSpares OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "RAIDset Available Spares. This indicates if this RAIDset has one or more spares designated for it that are not currently in use by another drive. Each octet present will be a physical drive ID that is an available spare for this logical drive. These are the same ID's which can be used as indexes into the physical drive table. An octet string of length zero indicates that there are no available spares for this logical drive." ::= { cpqCrLogDrvEntry 7 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.141.2.3.1.1.1 | cpqCrLogDrvCntlrIndex | 0 | 0 | Clustered RAID RAIDset Controller Index. This maps the RAIDsets into their respective controllers. Controller index 'i' under the… |
1.3.6.1.4.1.232.141.2.3.1.1.2 | cpqCrLogDrvIndex | 0 | 0 | Clustered RAID RAIDset Index. This logical drive number keeps track of multiple instances of logical drives which are on the same… |
1.3.6.1.4.1.232.141.2.3.1.1.3 | cpqCrLogDrvRAIDLevel | 0 | 0 | RAID Level. This shows the RAID level of the RAIDset. To change the RAID level, run the CL1850 Array Configuration Utility. The fol… |
1.3.6.1.4.1.232.141.2.3.1.1.4 | cpqCrLogDrvStatus | 0 | 0 | RAIDset Status. The RAIDset can be in one of the following states: Good (2) Indicates that the RAIDset is fully operational. Reduce… |
1.3.6.1.4.1.232.141.2.3.1.1.5 | cpqCrLogDrvRebuildPercentage | 0 | 0 | RAIDset Rebuild Percentage Complete. After a failed physical drive has been replaced, the physical drive must have its data rebui… |
1.3.6.1.4.1.232.141.2.3.1.1.8 | cpqCrLogDrvSize | 0 | 0 | RAIDset Size. This is the size of the RAIDset in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megab… |
1.3.6.1.4.1.232.141.2.3.1.1.9 | cpqCrLogDrvPhyDrvIDs | 0 | 0 | RAIDset Physical Drive IDs. This lists the physical drive IDs which are associated with this RAIDset. These are the same IDs whic… |
1.3.6.1.4.1.232.141.2.3.1.1.10 | cpqCrLogDrvCondition | 0 | 0 | RAIDset condition. This value represents the overall condition of this RAIDset and any associated physical drives. |
1.3.6.1.4.1.232.141.2.3.1.1.11 | cpqCrLogDrvPartitionIDs | 0 | 0 | RAIDset Logical Drive IDs. This lists the logical drive IDs which are associated with this RAIDset. These are the same IDs which … |