RAIDset Rebuild Percentage Complete.
After a failed physical drive has been replaced, the physical
drive must have its data rebuilt. This value shows how far
the rebuild process has progressed as a percentage.
When the value reaches 100, the rebuilding process is complete.
The drive array continues to operate in reduced mode while a
drive is rebuilding.
This value is only valid if the RAIDset Status is
reconstructing (6).
Parsed from file CPQCR1.MIB.txt
Company: None
Module: CPQCR-MIB
RAIDset Rebuild Percentage Complete.
After a failed physical drive has been replaced, the physical
drive must have its data rebuilt. This value shows how far
the rebuild process has progressed as a percentage.
When the value reaches 100, the rebuilding process is complete.
The drive array continues to operate in reduced mode while a
drive is rebuilding.
This value is only valid if the RAIDset Status is
reconstructing (6).
Parsed from file CPQCR-MIB.mib
Module: CPQCR-MIB
cpqCrLogDrvRebuildPercentage OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "RAIDset Rebuild Percentage Complete. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. This value shows how far the rebuild process has progressed as a percentage. When the value reaches 100, the rebuilding process is complete. The drive array continues to operate in reduced mode while a drive is rebuilding. This value is only valid if the RAIDset Status is reconstructing (6)." ::= { cpqCrLogDrvEntry 5 }
Vendor: Compaq
Module: CPQCR-MIB
[Automatically extracted from oidview.com]
cpqCrLogDrvRebuildPercentage OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "RAIDset Rebuild Percentage Complete. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. This value shows how far the rebuild process has progressed as a percentage. When the value reaches 100, the rebuilding process is complete. The drive array continues to operate in reduced mode while a drive is rebuilding. This value is only valid if the RAIDset Status is reconstructing (6)." ::= { cpqCrLogDrvEntry 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.141.2.3.1.1.1 | cpqCrLogDrvCntlrIndex | 0 | 0 | Clustered RAID RAIDset Controller Index. This maps the RAIDsets into their respective controllers. Controller index 'i' under the… |
1.3.6.1.4.1.232.141.2.3.1.1.2 | cpqCrLogDrvIndex | 0 | 0 | Clustered RAID RAIDset Index. This logical drive number keeps track of multiple instances of logical drives which are on the same… |
1.3.6.1.4.1.232.141.2.3.1.1.3 | cpqCrLogDrvRAIDLevel | 0 | 0 | RAID Level. This shows the RAID level of the RAIDset. To change the RAID level, run the CL1850 Array Configuration Utility. The fol… |
1.3.6.1.4.1.232.141.2.3.1.1.4 | cpqCrLogDrvStatus | 0 | 0 | RAIDset Status. The RAIDset can be in one of the following states: Good (2) Indicates that the RAIDset is fully operational. Reduce… |
1.3.6.1.4.1.232.141.2.3.1.1.7 | cpqCrLogDrvAvailSpares | 0 | 0 | RAIDset Available Spares. This indicates if this RAIDset has one or more spares designated for it that are not currently in use b… |
1.3.6.1.4.1.232.141.2.3.1.1.8 | cpqCrLogDrvSize | 0 | 0 | RAIDset Size. This is the size of the RAIDset in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megab… |
1.3.6.1.4.1.232.141.2.3.1.1.9 | cpqCrLogDrvPhyDrvIDs | 0 | 0 | RAIDset Physical Drive IDs. This lists the physical drive IDs which are associated with this RAIDset. These are the same IDs whic… |
1.3.6.1.4.1.232.141.2.3.1.1.10 | cpqCrLogDrvCondition | 0 | 0 | RAIDset condition. This value represents the overall condition of this RAIDset and any associated physical drives. |
1.3.6.1.4.1.232.141.2.3.1.1.11 | cpqCrLogDrvPartitionIDs | 0 | 0 | RAIDset Logical Drive IDs. This lists the logical drive IDs which are associated with this RAIDset. These are the same IDs which … |