Fibre Channel Array Logical Drive Physical Drive IDs.
This lists the physical drive IDs which are associated with this
logical drive. These are the same IDs which can be used as
indices into the physical drive table. Each byte of the string
is an index.
Parsed from file CPQFCA2.MIB.txt
Company: None
Module: CPQFCA-MIB
External Array Logical Drive Physical Drive IDs.
This lists the physical drive IDs which are associated with this
logical drive. These are the same IDs which can be used as
indices into the physical drive table. Each byte of the string
is an index.
Parsed from file CPQFCA-MIB.mib
Module: CPQFCA-MIB
cpqFcaLogDrvPhyDrvIDs OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Fibre Channel Array Logical Drive Physical Drive IDs. This lists the physical drive IDs which are associated with this logical drive. These are the same IDs which can be used as indices into the physical drive table. Each byte of the string is an index." ::= { cpqFcaLogDrvEntry 10 }
Vendor: Compaq
Module: CPQFCA-MIB
[Automatically extracted from oidview.com]
cpqFcaLogDrvPhyDrvIDs OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "External Array Logical Drive Physical Drive IDs. This lists the physical drive IDs which are associated with this logical drive. These are the same IDs which can be used as indices into the physical drive table. Each byte of the string is an index." ::= { cpqFcaLogDrvEntry 10 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.16.2.3.1.1.1 | cpqFcaLogDrvBoxIndex | 0 | 0 | External Array Logical Drive Storage Box Index. The storage box index indicates which storage box this logical drive is in. |
1.3.6.1.4.1.232.16.2.3.1.1.2 | cpqFcaLogDrvIndex | 0 | 0 | External Array Logical Drive Index. This logical drive number keeps track of multiple instances of logical drives which are in th… |
1.3.6.1.4.1.232.16.2.3.1.1.3 | cpqFcaLogDrvFaultTol | 0 | 0 | Logical Drive Fault Tolerance. This shows the fault tolerance mode of the logical drive. To change the fault tolerance mode, run … |
1.3.6.1.4.1.232.16.2.3.1.1.4 | cpqFcaLogDrvStatus | 0 | 0 | Logical Drive Status. The logical drive can be in one of the following states: Ok (2) Indicates that the logical drive is in norma… |
1.3.6.1.4.1.232.16.2.3.1.1.5 | cpqFcaLogDrvAutoRel | 0 | 0 | Logical Drive Auto-Reliability Delay. This value indicates how many seconds the logical drive will wait with no requests before b… |
1.3.6.1.4.1.232.16.2.3.1.1.6 | cpqFcaLogDrvPercentRebuild | 0 | 0 | Logical Drive Percent Rebuild. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. T… |
1.3.6.1.4.1.232.16.2.3.1.1.7 | cpqFcaLogDrvHasAccel | 0 | 0 | Logical Drive Has Array Accelerator Board. This indicates whether the logical drive has an Array Accelerator board configured and… |
1.3.6.1.4.1.232.16.2.3.1.1.8 | cpqFcaLogDrvAvailSpares | 0 | 0 | External Array Logical Drive Available Spares. This indicates if this logical drive has one or more spares designated for it that… |
1.3.6.1.4.1.232.16.2.3.1.1.9 | cpqFcaLogDrvSize | 0 | 0 | External Array Logical Drive Size. This is the size of the logical drive in megabytes. This value is calculated using the value … |
1.3.6.1.4.1.232.16.2.3.1.1.11 | cpqFcaLogDrvCondition | 0 | 0 | The Logical Drive condition. This value represents the overall condition of this logical drive and any associated physical drives. |
1.3.6.1.4.1.232.16.2.3.1.1.12 | cpqFcaLogDrvStripeSize | 0 | 0 | External Array Logical Drive Stripe Size. This is the size of a logical drive stripe in kilobytes. |
1.3.6.1.4.1.232.16.2.3.1.1.13 | cpqFcaLogDrvOsName | 0 | 0 | External Array Logical Drive OS Name. The OS name for this array logical drive. This field will be a null (size 0) string if the… |
1.3.6.1.4.1.232.16.2.3.1.1.14 | cpqFcaLogDrvBlinkTime | 0 | 0 | External Array Logical Drive Physical Drive Blink Time Count. The logical drive blink time variable allows the drive tray LEDs of… |
1.3.6.1.4.1.232.16.2.3.1.1.15 | cpqFcaLogDrvSpareReplaceMap | 0 | 0 | External Array Logical Drive Spare To Replacement Drive Map. This data structure contains the spare to physical drive replacement… |
1.3.6.1.4.1.232.16.2.3.1.1.16 | cpqFcaLogDrvRebuildingPhyDrv | 0 | 0 | External Array Logical Drive Physical Drive Rebuilding Index. This is the physical drive index of the physical drive that is curr… |
1.3.6.1.4.1.232.16.2.3.1.1.17 | cpqFcaLogDrvSnapshotResourceDrvIndex | 0 | 0 | External Array Logical Drive Snapshot Resource Drive Index. This is the logical drive index of the Snapshot Resource Volume assoc… |
1.3.6.1.4.1.232.16.2.3.1.1.18 | cpqFcaLogDrvSnapshotSourceDrvIndex | 0 | 0 | External Array Logical Drive Snapshot Source Drive Index. This is the drive index of the source logical drive associated with thi… |
1.3.6.1.4.1.232.16.2.3.1.1.19 | cpqFcaLogDrvPreferredPath | 0 | 0 | External Array Logical Drive Preferred Path. This identifies the preferred controller path to this logical drive in a redundant a… |
1.3.6.1.4.1.232.16.2.3.1.1.20 | cpqFcaLogDrvCurrentPath | 0 | 0 | External Array Logical Drive Current Path. This identifies the current controller path to this logical drive in a redundant activ… |