Reference record for OID 1.3.6.1.4.1.232.16.2.3.1.1.6



parent
1.3.6.1.4.1.232.16.2.3.1.1 (cpqFcaLogDrvEntry)
node code
6
node name
cpqFcaLogDrvPercentRebuild
dot oid
1.3.6.1.4.1.232.16.2.3.1.1.6
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaLogDrv(3) cpqFcaLogDrvTable(1) cpqFcaLogDrvEntry(1) cpqFcaLogDrvPercentRebuild(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaLogDrv(3) cpqFcaLogDrvTable(1) cpqFcaLogDrvEntry(1) cpqFcaLogDrvPercentRebuild(6)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaLogDrv(3) cpqFcaLogDrvTable(1) cpqFcaLogDrvEntry(1) cpqFcaLogDrvPercentRebuild(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaLogDrv(3) cpqFcaLogDrvTable(1) cpqFcaLogDrvEntry(1) cpqFcaLogDrvPercentRebuild(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaLogDrv(3) cpqFcaLogDrvTable(1) cpqFcaLogDrvEntry(1) cpqFcaLogDrvPercentRebuild(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaLogDrv(3) cpqFcaLogDrvTable(1) cpqFcaLogDrvEntry(1) cpqFcaLogDrvPercentRebuild(6)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaLogDrv(3) cpqFcaLogDrvTable(1) cpqFcaLogDrvEntry(1) cpqFcaLogDrvPercentRebuild(6)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaLogDrv(3) cpqFcaLogDrvTable(1) cpqFcaLogDrvEntry(1) cpqFcaLogDrvPercentRebuild(6)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaLogDrv/cpqFcaLogDrvTable/cpqFcaLogDrvEntry/cpqFcaLogDrvPercentRebuild
  • /iso/identified-organization/dod/internet/private/enterprise/hp/cpqFibreArray/cpqFcaComponent/cpqFcaLogDrv/cpqFcaLogDrvTable/cpqFcaLogDrvEntry/cpqFcaLogDrvPercentRebuild
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaLogDrv/cpqFcaLogDrvTable/cpqFcaLogDrvEntry/cpqFcaLogDrvPercentRebuild
  • /iso/org/dod/internet/private/enterprise/hp/cpqFibreArray/cpqFcaComponent/cpqFcaLogDrv/cpqFcaLogDrvTable/cpqFcaLogDrvEntry/cpqFcaLogDrvPercentRebuild
  • /iso/org/dod/internet/private/enterprises/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaLogDrv/cpqFcaLogDrvTable/cpqFcaLogDrvEntry/cpqFcaLogDrvPercentRebuild
  • /iso/org/dod/internet/private/enterprises/hp/cpqFibreArray/cpqFcaComponent/cpqFcaLogDrv/cpqFcaLogDrvTable/cpqFcaLogDrvEntry/cpqFcaLogDrvPercentRebuild
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaLogDrv/cpqFcaLogDrvTable/cpqFcaLogDrvEntry/cpqFcaLogDrvPercentRebuild
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqFibreArray/cpqFcaComponent/cpqFcaLogDrv/cpqFcaLogDrvTable/cpqFcaLogDrvEntry/cpqFcaLogDrvPercentRebuild
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/232/16/2/3/1/1/6

    Description by mibdepot

    Logical Drive Percent Rebuild.

    After a failed physical drive has been replaced, the physical
    drive must have its data rebuilt. This value the percent
    complete of the rebuild. When the value reaches 100, the
    rebuilding process is complete. The drive array continues to
    operate in interim recovery mode while a drive is rebuilding.

    When a logical volume is Expanding, the drive must redistribute
    the logical volume data across the physical drives. This value
    shows how many blocks of data still need to be redistributed.
    When the value reaches one hundred (100), the expand process
    is complete. The array continues to operate normally while
    the drive is expanding.

    This value is only valid if the Logical Drive Status is
    rebuilding (7) or expanding (12).

    If the value cannot be determined or a rebuild is not active,
    the value is set to 4,294,967,295.

    Parsed from file CPQFCA2.MIB.txt
    Company: None
    Module: CPQFCA-MIB

    Description by circitor

    Logical Drive Percent Rebuild.

    After a failed physical drive has been replaced, the physical
    drive must have its data rebuilt. This value the percent
    complete of the rebuild. When the value reaches 100, the
    rebuilding process is complete. The drive array continues to
    operate in interim recovery mode while a drive is rebuilding.

    When a logical volume is Expanding, the drive must redistribute
    the logical volume data across the physical drives. This value
    shows how many blocks of data still need to be redistributed.
    When the value reaches one hundred (100), the expand process
    is complete. The array continues to operate normally while
    the drive is expanding.

    This value is only valid if the Logical Drive Status is
    rebuilding (7) or expanding (12).

    If the value cannot be determined or a rebuild is not active,
    the value is set to 4,294,967,295.

    Parsed from file CPQFCA-MIB.mib
    Module: CPQFCA-MIB

    Information by mibdepot

    cpqFcaLogDrvPercentRebuild OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Logical Drive Percent Rebuild. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. This value the percent complete of the rebuild. When the value reaches 100, the rebuilding process is complete. The drive array continues to operate in interim recovery mode while a drive is rebuilding. When a logical volume is Expanding, the drive must redistribute the logical volume data across the physical drives. This value shows how many blocks of data still need to be redistributed. When the value reaches one hundred (100), the expand process is complete. The array continues to operate normally while the drive is expanding. This value is only valid if the Logical Drive Status is rebuilding (7) or expanding (12). If the value cannot be determined or a rebuild is not active, the value is set to 4,294,967,295." ::= { cpqFcaLogDrvEntry 6 }

    Information by oid_info

    Vendor: Compaq
    Module: CPQFCA-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    cpqFcaLogDrvPercentRebuild OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Logical Drive Percent Rebuild. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. This value the percent complete of the rebuild. When the value reaches 100, the rebuilding process is complete. The drive array continues to operate in interim recovery mode while a drive is rebuilding. When a logical volume is Expanding, the drive must redistribute the logical volume data across the physical drives. This value shows how many blocks of data still need to be redistributed. When the value reaches one hundred (100), the expand process is complete. The array continues to operate normally while the drive is expanding. This value is only valid if the Logical Drive Status is rebuilding (7) or expanding (12). If the value cannot be determined or a rebuild is not active, the value is set to 4,294,967,295." ::= { cpqFcaLogDrvEntry 6 }

    Brothers (19)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.232.16.2.3.1.1.1 cpqFcaLogDrvBoxIndex 0 0 External Array Logical Drive Storage Box Index.

    The storage box index indicates which storage box this
    logical drive is in.
    1.3.6.1.4.1.232.16.2.3.1.1.2 cpqFcaLogDrvIndex 0 0 External Array Logical Drive Index.

    This logical drive number keeps track of multiple instances of
    logical drives which are in th…
    1.3.6.1.4.1.232.16.2.3.1.1.3 cpqFcaLogDrvFaultTol 0 0 Logical Drive Fault Tolerance.

    This shows the fault tolerance mode of the logical drive.
    To change the fault tolerance mode, run …
    1.3.6.1.4.1.232.16.2.3.1.1.4 cpqFcaLogDrvStatus 0 0 Logical Drive Status.

    The logical drive can be in one of the following states:

    Ok (2)
    Indicates that the logical drive is in norma…
    1.3.6.1.4.1.232.16.2.3.1.1.5 cpqFcaLogDrvAutoRel 0 0 Logical Drive Auto-Reliability Delay.

    This value indicates how many seconds the logical drive will wait
    with no requests before b…
    1.3.6.1.4.1.232.16.2.3.1.1.7 cpqFcaLogDrvHasAccel 0 0 Logical Drive Has Array Accelerator Board.

    This indicates whether the logical drive has an Array Accelerator
    board configured and…
    1.3.6.1.4.1.232.16.2.3.1.1.8 cpqFcaLogDrvAvailSpares 0 0 External Array Logical Drive Available Spares.

    This indicates if this logical drive has one or more spares
    designated for it that…
    1.3.6.1.4.1.232.16.2.3.1.1.9 cpqFcaLogDrvSize 0 0 External Array Logical Drive Size.

    This is the size of the logical drive in megabytes. This value
    is calculated using the value …
    1.3.6.1.4.1.232.16.2.3.1.1.10 cpqFcaLogDrvPhyDrvIDs 0 0 External Array Logical Drive Physical Drive IDs.

    This lists the physical drive IDs which are associated with this
    logical drive. …
    1.3.6.1.4.1.232.16.2.3.1.1.11 cpqFcaLogDrvCondition 0 0 The Logical Drive condition.

    This value represents the overall condition of this logical drive and
    any associated physical drives.
    1.3.6.1.4.1.232.16.2.3.1.1.12 cpqFcaLogDrvStripeSize 0 0 External Array Logical Drive Stripe Size.

    This is the size of a logical drive stripe in kilobytes.
    1.3.6.1.4.1.232.16.2.3.1.1.13 cpqFcaLogDrvOsName 0 0 External Array Logical Drive OS Name.

    The OS name for this array logical drive. This field will be
    a null (size 0) string if the…
    1.3.6.1.4.1.232.16.2.3.1.1.14 cpqFcaLogDrvBlinkTime 0 0 External Array Logical Drive Physical Drive Blink Time Count.

    The logical drive blink time variable allows the drive tray LEDs
    of…
    1.3.6.1.4.1.232.16.2.3.1.1.15 cpqFcaLogDrvSpareReplaceMap 0 0 External Array Logical Drive Spare To Replacement Drive Map.

    This data structure contains the spare to physical drive
    replacement…
    1.3.6.1.4.1.232.16.2.3.1.1.16 cpqFcaLogDrvRebuildingPhyDrv 0 0 External Array Logical Drive Physical Drive Rebuilding Index.

    This is the physical drive index of the physical drive that is
    curr…
    1.3.6.1.4.1.232.16.2.3.1.1.17 cpqFcaLogDrvSnapshotResourceDrvIndex 0 0 External Array Logical Drive Snapshot Resource Drive Index.

    This is the logical drive index of the Snapshot Resource Volume
    assoc…
    1.3.6.1.4.1.232.16.2.3.1.1.18 cpqFcaLogDrvSnapshotSourceDrvIndex 0 0 External Array Logical Drive Snapshot Source Drive Index.

    This is the drive index of the source logical drive associated
    with thi…
    1.3.6.1.4.1.232.16.2.3.1.1.19 cpqFcaLogDrvPreferredPath 0 0 External Array Logical Drive Preferred Path.

    This identifies the preferred controller path to this logical
    drive in a redundant a…
    1.3.6.1.4.1.232.16.2.3.1.1.20 cpqFcaLogDrvCurrentPath 0 0 External Array Logical Drive Current Path.

    This identifies the current controller path to this logical drive
    in a redundant activ…