External Array Logical Drive Preferred Path.
This identifies the preferred controller path to this logical
drive in a redundant active/active configuration. The value is
the controller index. If the controller is not configured as
active/active, the value is set to -1.
Parsed from file CPQFCA2.MIB.txt
Company: None
Module: CPQFCA-MIB
External Array Logical Drive Preferred Path.
This identifies the preferred controller path to this logical
drive in a redundant active/active configuration. The value is
the controller index. If the controller is not configured as
active/active, the value is set to -1.
Parsed from file CPQFCA-MIB.mib
Module: CPQFCA-MIB
cpqFcaLogDrvPreferredPath OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "External Array Logical Drive Preferred Path. This identifies the preferred controller path to this logical drive in a redundant active/active configuration. The value is the controller index. If the controller is not configured as active/active, the value is set to -1." ::= { cpqFcaLogDrvEntry 19 }
Vendor: Compaq
Module: CPQFCA-MIB
[Automatically extracted from oidview.com]
cpqFcaLogDrvPreferredPath OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "External Array Logical Drive Preferred Path. This identifies the preferred controller path to this logical drive in a redundant active/active configuration. The value is the controller index. If the controller is not configured as active/active, the value is set to -1." ::= { cpqFcaLogDrvEntry 19 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.16.2.3.1.1.1 | cpqFcaLogDrvBoxIndex | 0 | 0 | External Array Logical Drive Storage Box Index. The storage box index indicates which storage box this logical drive is in. |
1.3.6.1.4.1.232.16.2.3.1.1.2 | cpqFcaLogDrvIndex | 0 | 0 | External Array Logical Drive Index. This logical drive number keeps track of multiple instances of logical drives which are in th… |
1.3.6.1.4.1.232.16.2.3.1.1.3 | cpqFcaLogDrvFaultTol | 0 | 0 | Logical Drive Fault Tolerance. This shows the fault tolerance mode of the logical drive. To change the fault tolerance mode, run … |
1.3.6.1.4.1.232.16.2.3.1.1.4 | cpqFcaLogDrvStatus | 0 | 0 | Logical Drive Status. The logical drive can be in one of the following states: Ok (2) Indicates that the logical drive is in norma… |
1.3.6.1.4.1.232.16.2.3.1.1.5 | cpqFcaLogDrvAutoRel | 0 | 0 | Logical Drive Auto-Reliability Delay. This value indicates how many seconds the logical drive will wait with no requests before b… |
1.3.6.1.4.1.232.16.2.3.1.1.6 | cpqFcaLogDrvPercentRebuild | 0 | 0 | Logical Drive Percent Rebuild. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. T… |
1.3.6.1.4.1.232.16.2.3.1.1.7 | cpqFcaLogDrvHasAccel | 0 | 0 | Logical Drive Has Array Accelerator Board. This indicates whether the logical drive has an Array Accelerator board configured and… |
1.3.6.1.4.1.232.16.2.3.1.1.8 | cpqFcaLogDrvAvailSpares | 0 | 0 | External Array Logical Drive Available Spares. This indicates if this logical drive has one or more spares designated for it that… |
1.3.6.1.4.1.232.16.2.3.1.1.9 | cpqFcaLogDrvSize | 0 | 0 | External Array Logical Drive Size. This is the size of the logical drive in megabytes. This value is calculated using the value … |
1.3.6.1.4.1.232.16.2.3.1.1.10 | cpqFcaLogDrvPhyDrvIDs | 0 | 0 | External Array Logical Drive Physical Drive IDs. This lists the physical drive IDs which are associated with this logical drive. … |
1.3.6.1.4.1.232.16.2.3.1.1.11 | cpqFcaLogDrvCondition | 0 | 0 | The Logical Drive condition. This value represents the overall condition of this logical drive and any associated physical drives. |
1.3.6.1.4.1.232.16.2.3.1.1.12 | cpqFcaLogDrvStripeSize | 0 | 0 | External Array Logical Drive Stripe Size. This is the size of a logical drive stripe in kilobytes. |
1.3.6.1.4.1.232.16.2.3.1.1.13 | cpqFcaLogDrvOsName | 0 | 0 | External Array Logical Drive OS Name. The OS name for this array logical drive. This field will be a null (size 0) string if the… |
1.3.6.1.4.1.232.16.2.3.1.1.14 | cpqFcaLogDrvBlinkTime | 0 | 0 | External Array Logical Drive Physical Drive Blink Time Count. The logical drive blink time variable allows the drive tray LEDs of… |
1.3.6.1.4.1.232.16.2.3.1.1.15 | cpqFcaLogDrvSpareReplaceMap | 0 | 0 | External Array Logical Drive Spare To Replacement Drive Map. This data structure contains the spare to physical drive replacement… |
1.3.6.1.4.1.232.16.2.3.1.1.16 | cpqFcaLogDrvRebuildingPhyDrv | 0 | 0 | External Array Logical Drive Physical Drive Rebuilding Index. This is the physical drive index of the physical drive that is curr… |
1.3.6.1.4.1.232.16.2.3.1.1.17 | cpqFcaLogDrvSnapshotResourceDrvIndex | 0 | 0 | External Array Logical Drive Snapshot Resource Drive Index. This is the logical drive index of the Snapshot Resource Volume assoc… |
1.3.6.1.4.1.232.16.2.3.1.1.18 | cpqFcaLogDrvSnapshotSourceDrvIndex | 0 | 0 | External Array Logical Drive Snapshot Source Drive Index. This is the drive index of the source logical drive associated with thi… |
1.3.6.1.4.1.232.16.2.3.1.1.20 | cpqFcaLogDrvCurrentPath | 0 | 0 | External Array Logical Drive Current Path. This identifies the current controller path to this logical drive in a redundant activ… |