Reference record for OID 1.3.6.1.4.1.232.16.2.3.1.1.5



parent
1.3.6.1.4.1.232.16.2.3.1.1 (cpqFcaLogDrvEntry)
node code
5
node name
cpqFcaLogDrvAutoRel
dot oid
1.3.6.1.4.1.232.16.2.3.1.1.5
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaLogDrv(3) cpqFcaLogDrvTable(1) cpqFcaLogDrvEntry(1) cpqFcaLogDrvAutoRel(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaLogDrv(3) cpqFcaLogDrvTable(1) cpqFcaLogDrvEntry(1) cpqFcaLogDrvAutoRel(5)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaLogDrv(3) cpqFcaLogDrvTable(1) cpqFcaLogDrvEntry(1) cpqFcaLogDrvAutoRel(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaLogDrv(3) cpqFcaLogDrvTable(1) cpqFcaLogDrvEntry(1) cpqFcaLogDrvAutoRel(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaLogDrv(3) cpqFcaLogDrvTable(1) cpqFcaLogDrvEntry(1) cpqFcaLogDrvAutoRel(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaLogDrv(3) cpqFcaLogDrvTable(1) cpqFcaLogDrvEntry(1) cpqFcaLogDrvAutoRel(5)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) compaq(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaLogDrv(3) cpqFcaLogDrvTable(1) cpqFcaLogDrvEntry(1) cpqFcaLogDrvAutoRel(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) hp(232) cpqFibreArray(16) cpqFcaComponent(2) cpqFcaLogDrv(3) cpqFcaLogDrvTable(1) cpqFcaLogDrvEntry(1) cpqFcaLogDrvAutoRel(5)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaLogDrv/cpqFcaLogDrvTable/cpqFcaLogDrvEntry/cpqFcaLogDrvAutoRel
  • /iso/identified-organization/dod/internet/private/enterprise/hp/cpqFibreArray/cpqFcaComponent/cpqFcaLogDrv/cpqFcaLogDrvTable/cpqFcaLogDrvEntry/cpqFcaLogDrvAutoRel
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaLogDrv/cpqFcaLogDrvTable/cpqFcaLogDrvEntry/cpqFcaLogDrvAutoRel
  • /iso/org/dod/internet/private/enterprise/hp/cpqFibreArray/cpqFcaComponent/cpqFcaLogDrv/cpqFcaLogDrvTable/cpqFcaLogDrvEntry/cpqFcaLogDrvAutoRel
  • /iso/org/dod/internet/private/enterprises/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaLogDrv/cpqFcaLogDrvTable/cpqFcaLogDrvEntry/cpqFcaLogDrvAutoRel
  • /iso/org/dod/internet/private/enterprises/hp/cpqFibreArray/cpqFcaComponent/cpqFcaLogDrv/cpqFcaLogDrvTable/cpqFcaLogDrvEntry/cpqFcaLogDrvAutoRel
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/compaq/cpqFibreArray/cpqFcaComponent/cpqFcaLogDrv/cpqFcaLogDrvTable/cpqFcaLogDrvEntry/cpqFcaLogDrvAutoRel
  • /iso/iso-identified-organization/dod/internet/private/enterprises/hp/cpqFibreArray/cpqFcaComponent/cpqFcaLogDrv/cpqFcaLogDrvTable/cpqFcaLogDrvEntry/cpqFcaLogDrvAutoRel
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/232/16/2/3/1/1/5

    Description by mibdepot

    Compaq Array Controller Logical Drive Auto-Reliability Delay.

    This value indicates how many seconds the logical drive will wait
    with no requests before beginning Auto-Reliability monitoring.
    For example, the default value is five, so the logical drive will
    begin Auto-Reliability monitoring if it receives no requests for
    five seconds. If the value is zero, the logical drive will not
    perform Auto-Reliability monitoring. Auto-Reliability only
    operates if the logical drive is configured in one of the fault
    tolerance modes.

    If the logical drive receives a request while performing
    Auto-Reliability monitoring, the drive will stop monitoring to
    process the request. Once it has satisfied all incoming requests,
    the drive will wait for the Auto-Reliability delay to expire
    before returning to Auto-Reliability monitoring.

    Auto-Reliability monitoring is a process to insure the highest
    level of data reliability. In this process each disk is scanned
    to verify that all of the sectors in the array are readable.
    If the Auto-Reliability monitoring process detects any bad
    sectors on the drives, it automatically remaps these bad sectors
    where possible.

    If the value cannot be determined or is not applicable, the
    value is set to -1.

    Parsed from file CPQFCA2.MIB.txt
    Company: None
    Module: CPQFCA-MIB

    Description by circitor

    Logical Drive Auto-Reliability Delay.

    This value indicates how many seconds the logical drive will wait
    with no requests before beginning Auto-Reliability monitoring.
    For example, the default value is five, so the logical drive will
    begin Auto-Reliability monitoring if it receives no requests for
    five seconds. If the value is zero, the logical drive will not
    perform Auto-Reliability monitoring. Auto-Reliability only
    operates if the logical drive is configured in one of the fault
    tolerance modes.

    If the logical drive receives a request while performing
    Auto-Reliability monitoring, the drive will stop monitoring to
    process the request. Once it has satisfied all incoming requests,
    the drive will wait for the Auto-Reliability delay to expire
    before returning to Auto-Reliability monitoring.

    Auto-Reliability monitoring is a process to insure the highest
    level of data reliability. In this process each disk is scanned
    to verify that all of the sectors in the array are readable.
    If the Auto-Reliability monitoring process detects any bad
    sectors on the drives, it automatically remaps these bad sectors
    where possible.

    If the value cannot be determined or is not applicable, the
    value is set to -1.

    Parsed from file CPQFCA-MIB.mib
    Module: CPQFCA-MIB

    Information by mibdepot

    cpqFcaLogDrvAutoRel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Compaq Array Controller Logical Drive Auto-Reliability Delay. This value indicates how many seconds the logical drive will wait with no requests before beginning Auto-Reliability monitoring. For example, the default value is five, so the logical drive will begin Auto-Reliability monitoring if it receives no requests for five seconds. If the value is zero, the logical drive will not perform Auto-Reliability monitoring. Auto-Reliability only operates if the logical drive is configured in one of the fault tolerance modes. If the logical drive receives a request while performing Auto-Reliability monitoring, the drive will stop monitoring to process the request. Once it has satisfied all incoming requests, the drive will wait for the Auto-Reliability delay to expire before returning to Auto-Reliability monitoring. Auto-Reliability monitoring is a process to insure the highest level of data reliability. In this process each disk is scanned to verify that all of the sectors in the array are readable. If the Auto-Reliability monitoring process detects any bad sectors on the drives, it automatically remaps these bad sectors where possible. If the value cannot be determined or is not applicable, the value is set to -1." ::= { cpqFcaLogDrvEntry 5 }

    Information by oid_info

    Vendor: Compaq
    Module: CPQFCA-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    cpqFcaLogDrvAutoRel OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Logical Drive Auto-Reliability Delay. This value indicates how many seconds the logical drive will wait with no requests before beginning Auto-Reliability monitoring. For example, the default value is five, so the logical drive will begin Auto-Reliability monitoring if it receives no requests for five seconds. If the value is zero, the logical drive will not perform Auto-Reliability monitoring. Auto-Reliability only operates if the logical drive is configured in one of the fault tolerance modes. If the logical drive receives a request while performing Auto-Reliability monitoring, the drive will stop monitoring to process the request. Once it has satisfied all incoming requests, the drive will wait for the Auto-Reliability delay to expire before returning to Auto-Reliability monitoring. Auto-Reliability monitoring is a process to insure the highest level of data reliability. In this process each disk is scanned to verify that all of the sectors in the array are readable. If the Auto-Reliability monitoring process detects any bad sectors on the drives, it automatically remaps these bad sectors where possible. If the value cannot be determined or is not applicable, the value is set to -1." ::= { cpqFcaLogDrvEntry 5 }

    Brothers (19)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.232.16.2.3.1.1.1 cpqFcaLogDrvBoxIndex 0 0 External Array Logical Drive Storage Box Index.

    The storage box index indicates which storage box this
    logical drive is in.
    1.3.6.1.4.1.232.16.2.3.1.1.2 cpqFcaLogDrvIndex 0 0 External Array Logical Drive Index.

    This logical drive number keeps track of multiple instances of
    logical drives which are in th…
    1.3.6.1.4.1.232.16.2.3.1.1.3 cpqFcaLogDrvFaultTol 0 0 Logical Drive Fault Tolerance.

    This shows the fault tolerance mode of the logical drive.
    To change the fault tolerance mode, run …
    1.3.6.1.4.1.232.16.2.3.1.1.4 cpqFcaLogDrvStatus 0 0 Logical Drive Status.

    The logical drive can be in one of the following states:

    Ok (2)
    Indicates that the logical drive is in norma…
    1.3.6.1.4.1.232.16.2.3.1.1.6 cpqFcaLogDrvPercentRebuild 0 0 Logical Drive Percent Rebuild.

    After a failed physical drive has been replaced, the physical
    drive must have its data rebuilt. T…
    1.3.6.1.4.1.232.16.2.3.1.1.7 cpqFcaLogDrvHasAccel 0 0 Logical Drive Has Array Accelerator Board.

    This indicates whether the logical drive has an Array Accelerator
    board configured and…
    1.3.6.1.4.1.232.16.2.3.1.1.8 cpqFcaLogDrvAvailSpares 0 0 External Array Logical Drive Available Spares.

    This indicates if this logical drive has one or more spares
    designated for it that…
    1.3.6.1.4.1.232.16.2.3.1.1.9 cpqFcaLogDrvSize 0 0 External Array Logical Drive Size.

    This is the size of the logical drive in megabytes. This value
    is calculated using the value …
    1.3.6.1.4.1.232.16.2.3.1.1.10 cpqFcaLogDrvPhyDrvIDs 0 0 External Array Logical Drive Physical Drive IDs.

    This lists the physical drive IDs which are associated with this
    logical drive. …
    1.3.6.1.4.1.232.16.2.3.1.1.11 cpqFcaLogDrvCondition 0 0 The Logical Drive condition.

    This value represents the overall condition of this logical drive and
    any associated physical drives.
    1.3.6.1.4.1.232.16.2.3.1.1.12 cpqFcaLogDrvStripeSize 0 0 External Array Logical Drive Stripe Size.

    This is the size of a logical drive stripe in kilobytes.
    1.3.6.1.4.1.232.16.2.3.1.1.13 cpqFcaLogDrvOsName 0 0 External Array Logical Drive OS Name.

    The OS name for this array logical drive. This field will be
    a null (size 0) string if the…
    1.3.6.1.4.1.232.16.2.3.1.1.14 cpqFcaLogDrvBlinkTime 0 0 External Array Logical Drive Physical Drive Blink Time Count.

    The logical drive blink time variable allows the drive tray LEDs
    of…
    1.3.6.1.4.1.232.16.2.3.1.1.15 cpqFcaLogDrvSpareReplaceMap 0 0 External Array Logical Drive Spare To Replacement Drive Map.

    This data structure contains the spare to physical drive
    replacement…
    1.3.6.1.4.1.232.16.2.3.1.1.16 cpqFcaLogDrvRebuildingPhyDrv 0 0 External Array Logical Drive Physical Drive Rebuilding Index.

    This is the physical drive index of the physical drive that is
    curr…
    1.3.6.1.4.1.232.16.2.3.1.1.17 cpqFcaLogDrvSnapshotResourceDrvIndex 0 0 External Array Logical Drive Snapshot Resource Drive Index.

    This is the logical drive index of the Snapshot Resource Volume
    assoc…
    1.3.6.1.4.1.232.16.2.3.1.1.18 cpqFcaLogDrvSnapshotSourceDrvIndex 0 0 External Array Logical Drive Snapshot Source Drive Index.

    This is the drive index of the source logical drive associated
    with thi…
    1.3.6.1.4.1.232.16.2.3.1.1.19 cpqFcaLogDrvPreferredPath 0 0 External Array Logical Drive Preferred Path.

    This identifies the preferred controller path to this logical
    drive in a redundant a…
    1.3.6.1.4.1.232.16.2.3.1.1.20 cpqFcaLogDrvCurrentPath 0 0 External Array Logical Drive Current Path.

    This identifies the current controller path to this logical drive
    in a redundant activ…