node name
rPDU2GroupTotalPower
dot oid
1.3.6.1.4.1.318.1.1.26.11.2
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) rPDU2(26) rPDU2Group(11) rPDU2GroupTotalPower(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) rPDU2(26) rPDU2Group(11) rPDU2GroupTotalPower(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) rPDU2(26) rPDU2Group(11) rPDU2GroupTotalPower(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) rPDU2(26) rPDU2Group(11) rPDU2GroupTotalPower(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) rPDU2(26) rPDU2Group(11) rPDU2GroupTotalPower(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) rPDU2(26) rPDU2Group(11) rPDU2GroupTotalPower(2)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/apc/products/hardware/rPDU2/rPDU2Group/rPDU2GroupTotalPower
  • /iso/identified-organization/dod/internet/private/enterprises/apc/products/hardware/rPDU2/rPDU2Group/rPDU2GroupTotalPower
  • /iso/org/dod/internet/private/enterprise/apc/products/hardware/rPDU2/rPDU2Group/rPDU2GroupTotalPower
  • /iso/org/dod/internet/private/enterprises/apc/products/hardware/rPDU2/rPDU2Group/rPDU2GroupTotalPower
  • /iso/iso-identified-organization/dod/internet/private/enterprise/apc/products/hardware/rPDU2/rPDU2Group/rPDU2GroupTotalPower
  • /iso/iso-identified-organization/dod/internet/private/enterprises/apc/products/hardware/rPDU2/rPDU2Group/rPDU2GroupTotalPower
  • Description by mibdepot

    Getting this OID will return the total power consumption of the Rack PDU
    Network Port Sharing (NPS) group devices in hundredths of kilowatts.
    Queries to guest units in an NPS group are not applicable and will
    return 0.

    Parsed from file powernet.mib.txt
    Company: None
    Module: PowerNet-MIB

    Description by circitor

    Getting this OID will return the total power consumption of the Rack PDU
    group devices in hundredths of kilowatts.

    Parsed from file PowerNet-MIB.mib
    Module: PowerNet-MIB

    Information by mibdepot

    rPDU2GroupTotalPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Getting this OID will return the total power consumption of the Rack PDU Network Port Sharing (NPS) group devices in hundredths of kilowatts. Queries to guest units in an NPS group are not applicable and will return 0." ::= { rPDU2Group 2 }

    Information by circitor

    rPDU2GroupTotalPower OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Getting this OID will return the total power consumption of the Rack PDU group devices in hundredths of kilowatts." ::= { rPDU2Group 2 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.318)

    Yoest Peter C.

    Brothers (3)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.26.11.1 rPDU2GroupNumberOfDevices 0 0 Getting this OID will return the number of Rack PDU devices contributing
    to the group power and energy values.
    1.3.6.1.4.1.318.1.1.26.11.3 rPDU2GroupTotalEnergy 0 0 Getting this OID will return the total energy consumption of the Rack PDU
    group devices in tenths of kilowatt-hours.

    To reset th…
    1.3.6.1.4.1.318.1.1.26.11.4 rPDU2GroupEnergyReset 0 0 Setting this OID to reset (2) will cause the device energy meter value
    on each device in the Rack PDU group to be reset to zero.…