Reference record for OID 1.3.6.1.4.1.318.1.1.26.11.3



parent
1.3.6.1.4.1.318.1.1.26.11 (rPDU2Group)
node code
3
node name
rPDU2GroupTotalEnergy
dot oid
1.3.6.1.4.1.318.1.1.26.11.3
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) rPDU2(26) rPDU2Group(11) rPDU2GroupTotalEnergy(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) rPDU2(26) rPDU2Group(11) rPDU2GroupTotalEnergy(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) rPDU2(26) rPDU2Group(11) rPDU2GroupTotalEnergy(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) rPDU2(26) rPDU2Group(11) rPDU2GroupTotalEnergy(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) rPDU2(26) rPDU2Group(11) rPDU2GroupTotalEnergy(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) rPDU2(26) rPDU2Group(11) rPDU2GroupTotalEnergy(3)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/apc/products/hardware/rPDU2/rPDU2Group/rPDU2GroupTotalEnergy
  • /iso/identified-organization/dod/internet/private/enterprises/apc/products/hardware/rPDU2/rPDU2Group/rPDU2GroupTotalEnergy
  • /iso/org/dod/internet/private/enterprise/apc/products/hardware/rPDU2/rPDU2Group/rPDU2GroupTotalEnergy
  • /iso/org/dod/internet/private/enterprises/apc/products/hardware/rPDU2/rPDU2Group/rPDU2GroupTotalEnergy
  • /iso/iso-identified-organization/dod/internet/private/enterprise/apc/products/hardware/rPDU2/rPDU2Group/rPDU2GroupTotalEnergy
  • /iso/iso-identified-organization/dod/internet/private/enterprises/apc/products/hardware/rPDU2/rPDU2Group/rPDU2GroupTotalEnergy
  • Description by mibdepot

    Getting this OID will return the total energy consumption of the Rack PDU
    Network Port Sharing (NPS) group devices in tenths of kilowatt-hours.

    To reset the energy meters for each of the Rack PDU devices that contribute
    to this value, see the rPDU2GroupEnergyReset OID.

    To view the start time for each of the Rack PDU device energy meters that
    contribute to this value, see the rPDU2DeviceStatusEnergyStartTime OID.

    Queries to guest units in an NPS group are not applicable and will
    return 0.

    Parsed from file powernet.mib.txt
    Company: None
    Module: PowerNet-MIB

    Description by circitor

    Getting this OID will return the total energy consumption of the Rack PDU
    group devices in tenths of kilowatt-hours.

    To reset the energy meters for each of the Rack PDU devices that contribute
    to this value, see the rPDU2GroupEnergyReset OID.

    To view the start time for each of the Rack PDU device energy meters that
    contribute to this value, see the rPDU2DeviceStatusEnergyStartTime OID.

    Parsed from file PowerNet-MIB.mib
    Module: PowerNet-MIB

    Information by mibdepot

    rPDU2GroupTotalEnergy OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Getting this OID will return the total energy consumption of the Rack PDU Network Port Sharing (NPS) group devices in tenths of kilowatt-hours. To reset the energy meters for each of the Rack PDU devices that contribute to this value, see the rPDU2GroupEnergyReset OID. To view the start time for each of the Rack PDU device energy meters that contribute to this value, see the rPDU2DeviceStatusEnergyStartTime OID. Queries to guest units in an NPS group are not applicable and will return 0." ::= { rPDU2Group 3 }

    Information by circitor

    rPDU2GroupTotalEnergy OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Getting this OID will return the total energy consumption of the Rack PDU group devices in tenths of kilowatt-hours. To reset the energy meters for each of the Rack PDU devices that contribute to this value, see the rPDU2GroupEnergyReset OID. To view the start time for each of the Rack PDU device energy meters that contribute to this value, see the rPDU2DeviceStatusEnergyStartTime OID." ::= { rPDU2Group 3 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.318)

    Yoest Peter C.

    Brothers (3)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.26.11.1 rPDU2GroupNumberOfDevices 0 0 Getting this OID will return the number of Rack PDU devices contributing
    to the group power and energy values.
    1.3.6.1.4.1.318.1.1.26.11.2 rPDU2GroupTotalPower 0 0 Getting this OID will return the total power consumption of the Rack PDU
    group devices in hundredths of kilowatts.
    1.3.6.1.4.1.318.1.1.26.11.4 rPDU2GroupEnergyReset 0 0 Setting this OID to reset (2) will cause the device energy meter value
    on each device in the Rack PDU group to be reset to zero.…