Setting this OID to reset (2) will cause the device energy meter value
on each device in the Rack PDU Network Port Sharing (NPS) group to be
reset to zero.
Each device in the Rack PDU group will also have its corresponding
rPDU2DeviceStatusEnergyStartTime OID value updated.
Getting this OID in models that support this feature will do nothing
and return the noOperation(1) value.
Models that do not support this feature, as well as guest units in an
NPS group, will respond to this OID with a value of notSupported (3).
Attempts to set this OID in these units will fail.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
Setting this OID to reset (2) will cause the device energy meter value
on each device in the Rack PDU group to be reset to zero.
Each device in the Rack PDU group will also have its corresponding
rPDU2DeviceStatusEnergyStartTime OID value updated.
Getting this OID in models that support this feature will do nothing
and return the noOperation(1) value.
Models that do not support this feature will respond to this OID
with a value of notSupported (3). Attempts to set this OID
in these models will fail.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
rPDU2GroupEnergyReset OBJECT-TYPE SYNTAX INTEGER { noOperation (1), reset (2), notSupported (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this OID to reset (2) will cause the device energy meter value on each device in the Rack PDU Network Port Sharing (NPS) group to be reset to zero. Each device in the Rack PDU group will also have its corresponding rPDU2DeviceStatusEnergyStartTime OID value updated. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not support this feature, as well as guest units in an NPS group, will respond to this OID with a value of notSupported (3). Attempts to set this OID in these units will fail." ::= { rPDU2Group 4 }
rPDU2GroupEnergyReset OBJECT-TYPE SYNTAX INTEGER { noOperation (1), reset (2), notSupported (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this OID to reset (2) will cause the device energy meter value on each device in the Rack PDU group to be reset to zero. Each device in the Rack PDU group will also have its corresponding rPDU2DeviceStatusEnergyStartTime OID value updated. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of notSupported (3). Attempts to set this OID in these models will fail." ::= { rPDU2Group 4 }