Reference record for OID 1.3.6.1.4.1.5812.1.3.13


parent
1.3.6.1.4.1.5812.1.3 (systime)
node code
13
node name
systimePriCSHVTime
dot oid
1.3.6.1.4.1.5812.1.3.13
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) coriolisMibs(5812) device(1) systime(3) systimePriCSHVTime(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) coriolisMibs(5812) device(1) systime(3) systimePriCSHVTime(13)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) coriolisMibs(5812) device(1) systime(3) systimePriCSHVTime(13)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) coriolisMibs(5812) device(1) systime(3) systimePriCSHVTime(13)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) coriolisMibs(5812) device(1) systime(3) systimePriCSHVTime(13)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) coriolisMibs(5812) device(1) systime(3) systimePriCSHVTime(13)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/coriolisMibs/device/systime/systimePriCSHVTime
  • /iso/identified-organization/dod/internet/private/enterprises/coriolisMibs/device/systime/systimePriCSHVTime
  • /iso/org/dod/internet/private/enterprise/coriolisMibs/device/systime/systimePriCSHVTime
  • /iso/org/dod/internet/private/enterprises/coriolisMibs/device/systime/systimePriCSHVTime
  • /iso/iso-identified-organization/dod/internet/private/enterprise/coriolisMibs/device/systime/systimePriCSHVTime
  • /iso/iso-identified-organization/dod/internet/private/enterprises/coriolisMibs/device/systime/systimePriCSHVTime
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/5812/1/3/13

    Description by mibdepot

    Primary Clock Source Holdover Validation Time. This is the amount of
    time required to validate the primary clock source when in the holdover
    state. Default is 10 seconds.

    Parsed from file device.mib.txt
    Company: None
    Module: DEVICE-MIB

    Description by circitor

    Primary Clock Source Holdover Validation Time. This is the amount of
    time required to validate the primary clock source when in the holdover
    state. Default is 10 seconds.

    Parsed from file DEVICE-MIB.mib
    Module: DEVICE-MIB

    Information by oid_info

    Vendor: Coriolis Networks
    Module: DEVICE-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    systimePriCSHVTime OBJECT-TYPE SYNTAX INTEGER(1..60) MAX-ACCESS read-write STATUS current DESCRIPTION " Primary Clock Source Holdover Validation Time. This is the amount of time required to validate the primary clock source when in the holdover state. Default is 10 seconds." ::= { systime 13 }

    Information by circitor

    systimePriCSHVTime OBJECT-TYPE SYNTAX INTEGER(1..60) MAX-ACCESS read-write STATUS current DESCRIPTION " Primary Clock Source Holdover Validation Time. This is the amount of time required to validate the primary clock source when in the holdover state. Default is 10 seconds." ::= { systime 13 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.5812)

    Anil Navkal

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.5812)

    Anil Navkal

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.5812.1.3.13.0 systimePriCSHVTime 0 0 None

    Brothers (22)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.5812.1.3.1 systimeTimingMode 1 1 The type of timing used by the device.

    External (default for OptiFlow 5000)
    - Primary Clock Source is always BITS1.
    - Secondary…
    1.3.6.1.4.1.5812.1.3.2 systimePriBITSFraming 1 1 This is the Primary BITS basic line framing. Default is T1-ESF-4K.

    t1SF - Super Frame framing method used on T1 circuits. SF c…
    1.3.6.1.4.1.5812.1.3.3 systimeSecBITSFraming 1 1 This is the Secondary BITS basic line framing. Default is T1-ESF-4K.

    t1SF - Super Frame framing method used on T1 circuits. SF…
    1.3.6.1.4.1.5812.1.3.4 systimePriBITSCoding 1 1 This is the primary BITS line coding. Default is B8ZS. Valid when
    timing_mode is EXT.
    AMI - Alternate Mask Inversion (valid wh…
    1.3.6.1.4.1.5812.1.3.5 systimeSecBITSCoding 1 1 This is the seconday BITS line coding. Default is B8ZS. Valid when
    timing mode is EXT.
    AMI - Alternate Mask Inversion (valid w…
    1.3.6.1.4.1.5812.1.3.6 systimePriClkSrcId 1 1 This is the primary timing interface clock.

    bits1 - Valid when the timing mode is EXT.
    bits2 - Valid when the timing mode is EXT…
    1.3.6.1.4.1.5812.1.3.7 systimeSecClkSrcId 1 1 This is the secondary timing interface clock

    bits1 - Valid when the timing mode is EXT.
    bits2 - Valid when the timing mode is EXT…
    1.3.6.1.4.1.5812.1.3.8 systimeClkReference 1 1 Automatic(default) - This automatically selects a Stratum 3 or better
    clock from the Primary Clock Source, Secondary Clock Sourc…
    1.3.6.1.4.1.5812.1.3.9 systimeClkRevertive 1 1 Sets the method by which the device (equipment) returns to using the
    Primary Clock Source after the Primary Clock Source has fai…
    1.3.6.1.4.1.5812.1.3.10 systimeStandbyClkEnable 1 1 This enables use of standby management module clock reference.
    It enables using the primary clock source, secondary clock source…
    1.3.6.1.4.1.5812.1.3.11 systimePriCSNVTime 1 1 Primary Clock Source Normal Validation Time. This is the amount of
    time required to validate the primary clock source when not i…
    1.3.6.1.4.1.5812.1.3.12 systimeSecCSNVTime 1 1 Secondary Clock Source Normal Validation Time. This is the amount of
    time required to validate the secondary clock source when n…
    1.3.6.1.4.1.5812.1.3.14 systimeSecCSHVTime 1 1 Secondary Clock Source Holdover Validation Time. This is the amount of
    time required to validate the secondary clock source when…
    1.3.6.1.4.1.5812.1.3.15 systimePriCSUseLimit 1 1 This is the number of times the primary clock source may be
    used over the time interval primary clock source use interval
    (systim…
    1.3.6.1.4.1.5812.1.3.16 systimeSecCSUseLimit 1 1 This is the number of times the secondary clock source may be
    used over the time interval Secondary clock source use interval
    (sy…
    1.3.6.1.4.1.5812.1.3.17 systimeStandbyCSUseLimit 1 1 This is the number of times the standby clock source may be
    used over the time interval standby clock source use interval
    (systim…
    1.3.6.1.4.1.5812.1.3.18 systimePriCSUseInterval 1 1 This is the time interval used to reset the Primary Clock Source used
    count. Ranges from 1 to 96 hours. Default is 1 hour.
    1.3.6.1.4.1.5812.1.3.19 systimeSecCSUseInterval 1 1 This is the time interval used to reset the Secondary Clock Source used
    count. Ranges from 1 to 96 hours. Default is 1 hour.
    1.3.6.1.4.1.5812.1.3.20 systimeStandbyCSUseInterval 1 1 This is the time interval used to reset the Standby Clock Source used
    count. Ranges from 1 to 96 hours. Default is 1 hour.
    1.3.6.1.4.1.5812.1.3.21 systimeCREventEnable 1 1 This generates an alarm when the clock reference used changes from either
    the primary or the secondary. Default is Enable.
    1.3.6.1.4.1.5812.1.3.22 systimeCRInUse 1 1 This indicates the current clock reference.
    Automatic(default) - This automatically selects a Stratum 3 or better
    clock from the …
    1.3.6.1.4.1.5812.1.3.23 systimeCRUsedCount 1 1 This indicates the number of times this clock had been used.