OID reference

systimeSecCSUseInterval

1.3.6.1.4.1.5812.1.3.19

Description

This is the time interval used to reset the Secondary Clock Source used count. Ranges from 1 to 96 hours. Default is 1 hour.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.5812.1.3 (systime)
Node code
19
Node name
systimeSecCSUseInterval
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.5812.1.3.19
URN notation
urn:oid:1.3.6.1.4.1.5812.1.3.19
Type
OBJECT-TYPE
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 5812 1 3 19}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) coriolisMibs(5812) device(1) systime(3) systimeSecCSUseInterval(19)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) coriolisMibs(5812) device(1) systime(3) systimeSecCSUseInterval(19)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) coriolisMibs(5812) device(1) systime(3) systimeSecCSUseInterval(19)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) coriolisMibs(5812) device(1) systime(3) systimeSecCSUseInterval(19)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) coriolisMibs(5812) device(1) systime(3) systimeSecCSUseInterval(19)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) coriolisMibs(5812) device(1) systime(3) systimeSecCSUseInterval(19)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) coriolisMibs(5812) device(1) systime(3) systimeSecCSUseInterval(19)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) coriolisMibs(5812) device(1) systime(3) systimeSecCSUseInterval(19)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) coriolisMibs(5812) device(1) systime(3) systimeSecCSUseInterval(19)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) coriolisMibs(5812) device(1) systime(3) systimeSecCSUseInterval(19)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) coriolisMibs(5812) device(1) systime(3) systimeSecCSUseInterval(19)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) coriolisMibs(5812) device(1) systime(3) systimeSecCSUseInterval(19)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) coriolisMibs(5812) device(1) systime(3) systimeSecCSUseInterval(19)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) coriolisMibs(5812) device(1) systime(3) systimeSecCSUseInterval(19)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) coriolisMibs(5812) device(1) systime(3) systimeSecCSUseInterval(19)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) coriolisMibs(5812) device(1) systime(3) systimeSecCSUseInterval(19)}
OID-IRI notation
  • /1/3/6/1/4/1/5812/1/3/19
  • /ISO/Identified-Organization/6/1/4/1/5812/1/3/19
  • /ISO/3/6/1/4/1/5812/1/3/19
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/coriolisMibs/device/systime/systimeSecCSUseInterval
  • /iso/identified-organization/dod/internet/private/enterprises/coriolisMibs/device/systime/systimeSecCSUseInterval
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/coriolisMibs/device/systime/systimeSecCSUseInterval
  • /iso/identified-organization/dod/internet/private/vendor-objects/coriolisMibs/device/systime/systimeSecCSUseInterval
  • /iso/org/dod/internet/private/enterprise/coriolisMibs/device/systime/systimeSecCSUseInterval
  • /iso/org/dod/internet/private/enterprises/coriolisMibs/device/systime/systimeSecCSUseInterval
  • /iso/org/dod/internet/private/ldap-enterprise/coriolisMibs/device/systime/systimeSecCSUseInterval
  • /iso/org/dod/internet/private/vendor-objects/coriolisMibs/device/systime/systimeSecCSUseInterval
  • /iso/iso-identified-organization/dod/internet/private/enterprise/coriolisMibs/device/systime/systimeSecCSUseInterval
  • /iso/iso-identified-organization/dod/internet/private/enterprises/coriolisMibs/device/systime/systimeSecCSUseInterval
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/coriolisMibs/device/systime/systimeSecCSUseInterval
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/coriolisMibs/device/systime/systimeSecCSUseInterval
  • /iso/iso-organization/dod/internet/private/enterprise/coriolisMibs/device/systime/systimeSecCSUseInterval
  • /iso/iso-organization/dod/internet/private/enterprises/coriolisMibs/device/systime/systimeSecCSUseInterval
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/coriolisMibs/device/systime/systimeSecCSUseInterval
  • /iso/iso-organization/dod/internet/private/vendor-objects/coriolisMibs/device/systime/systimeSecCSUseInterval

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
current
Allowed ranges
1–96

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.5812.1.3.19.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Historical records

Additional source information

Information from OID Repository
Vendor: Coriolis Networks
Module: DEVICE-MIB

[Automatically extracted from oidview.com]
Information from MIBdepot
systimeSecCSUseInterval OBJECT-TYPE
          SYNTAX INTEGER(1..96)
          MAX-ACCESS read-write
          STATUS current
          DESCRIPTION
          " This is the time interval used to reset the Secondary Clock Source used
            count. Ranges from 1 to 96 hours. Default is 1 hour."
          ::= { systime 19 }
Information from Circitor
systimeSecCSUseInterval OBJECT-TYPE
          SYNTAX INTEGER(1..96)
          MAX-ACCESS read-write
          STATUS current
          DESCRIPTION
          " This is the time interval used to reset the Secondary Clock Source used
            count. Ranges from 1 to 96 hours. Default is 1 hour."
          ::= { systime 19 }

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.5812)

Anil Navkal

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.5812)

Anil Navkal

Direct children (1)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.5812.1.3.19.0 systimeSecCSUseInterval00

Siblings (22)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.5812.1.3.1 systimeTimingMode11 The type of timing used by the device.

External (default for OptiFlow 5000)
- Primary Clock Source is always BITS1.
- Secondary…
1.3.6.1.4.1.5812.1.3.2 systimePriBITSFraming11 This is the Primary BITS basic line framing. Default is T1-ESF-4K.

t1SF - Super Frame framing method used on T1 circuits. SF c…
1.3.6.1.4.1.5812.1.3.3 systimeSecBITSFraming11 This is the Secondary BITS basic line framing. Default is T1-ESF-4K.

t1SF - Super Frame framing method used on T1 circuits. SF…
1.3.6.1.4.1.5812.1.3.4 systimePriBITSCoding11 This is the primary BITS line coding. Default is B8ZS. Valid when
timing_mode is EXT.
AMI - Alternate Mask Inversion (valid wh…
1.3.6.1.4.1.5812.1.3.5 systimeSecBITSCoding11 This is the seconday BITS line coding. Default is B8ZS. Valid when
timing mode is EXT.
AMI - Alternate Mask Inversion (valid w…
1.3.6.1.4.1.5812.1.3.6 systimePriClkSrcId11 This is the primary timing interface clock.

bits1 - Valid when the timing mode is EXT.
bits2 - Valid when the timing mode is EXT…
1.3.6.1.4.1.5812.1.3.7 systimeSecClkSrcId11 This is the secondary timing interface clock

bits1 - Valid when the timing mode is EXT.
bits2 - Valid when the timing mode is EXT…
1.3.6.1.4.1.5812.1.3.8 systimeClkReference11 Automatic(default) - This automatically selects a Stratum 3 or better
clock from the Primary Clock Source, Secondary Clock Sourc…
1.3.6.1.4.1.5812.1.3.9 systimeClkRevertive11 Sets the method by which the device (equipment) returns to using the
Primary Clock Source after the Primary Clock Source has fai…
1.3.6.1.4.1.5812.1.3.10 systimeStandbyClkEnable11 This enables use of standby management module clock reference.
It enables using the primary clock source, secondary clock source
…
1.3.6.1.4.1.5812.1.3.11 systimePriCSNVTime11 Primary Clock Source Normal Validation Time. This is the amount of
time required to validate the primary clock source when not i…
1.3.6.1.4.1.5812.1.3.12 systimeSecCSNVTime11 Secondary Clock Source Normal Validation Time. This is the amount of
time required to validate the secondary clock source when n…
1.3.6.1.4.1.5812.1.3.13 systimePriCSHVTime11 Primary Clock Source Holdover Validation Time. This is the amount of
time required to validate the primary clock source when in …
1.3.6.1.4.1.5812.1.3.14 systimeSecCSHVTime11 Secondary Clock Source Holdover Validation Time. This is the amount of
time required to validate the secondary clock source when…
1.3.6.1.4.1.5812.1.3.15 systimePriCSUseLimit11 This is the number of times the primary clock source may be
used over the time interval primary clock source use interval
(systim…
1.3.6.1.4.1.5812.1.3.16 systimeSecCSUseLimit11 This is the number of times the secondary clock source may be
used over the time interval Secondary clock source use interval
(sy…
1.3.6.1.4.1.5812.1.3.17 systimeStandbyCSUseLimit11 This is the number of times the standby clock source may be
used over the time interval standby clock source use interval
(systim…
1.3.6.1.4.1.5812.1.3.18 systimePriCSUseInterval11 This is the time interval used to reset the Primary Clock Source used
count. Ranges from 1 to 96 hours. Default is 1 hour.
1.3.6.1.4.1.5812.1.3.20 systimeStandbyCSUseInterval11 This is the time interval used to reset the Standby Clock Source used
count. Ranges from 1 to 96 hours. Default is 1 hour.
1.3.6.1.4.1.5812.1.3.21 systimeCREventEnable11 This generates an alarm when the clock reference used changes from either
the primary or the secondary. Default is Enable.
1.3.6.1.4.1.5812.1.3.22 systimeCRInUse11 This indicates the current clock reference.
Automatic(default) - This automatically selects a Stratum 3 or better
clock from the …
1.3.6.1.4.1.5812.1.3.23 systimeCRUsedCount11 This indicates the number of times this clock had been used.