This object is ONLY meaningful when the object
s3TrThreshEntObject has the value station(6).
If the object s3TrThreshEntObject has the
value port(4) or ring(5) the agent will
automatically set this object to
00:00:00:00:00:00 during row creation.
When meaningful, it contains the Individual
MAC address of the station the for which the
station threshold applies.
When written the value must be an active
station's MAC address, which is defined as the
station participating in the ring poll process.
Notes: 1.) The station does not have to be active
for insertions and deinsertions.
2.) Only Individual MAC addresses are
supported.
Parsed from file s3tok430.mib.txt
Company: nortel
Module: SYNOPTICS-TOKENRING-MIB
Vendor: Nortel Networks
Module: SYNOPTICS-TOKENRING-MIB (s3tok430.mib)
Type: TABULAR
Access: read-write
Syntax: PhysAddress
(
6 )
Automatically extracted from www.mibdepot.com
s3TrThreshMacAddr OBJECT-TYPE SYNTAX PhysAddress (SIZE(6)) ACCESS read-write STATUS mandatory DESCRIPTION "This object is ONLY meaningful when the object s3TrThreshEntObject has the value station(6). If the object s3TrThreshEntObject has the value port(4) or ring(5) the agent will automatically set this object to 00:00:00:00:00:00 during row creation. When meaningful, it contains the Individual MAC address of the station the for which the station threshold applies. When written the value must be an active station's MAC address, which is defined as the station participating in the ring poll process. Notes: 1.) The station does not have to be active for insertions and deinsertions. 2.) Only Individual MAC addresses are supported." ::= { s3TrThresholdEntry 13 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.45.1.3.3.8.1.1.1 | s3TrThreshEntIndex | 0 | 0 | The index into the threshold table. |
1.3.6.1.4.1.45.1.3.3.8.1.1.2 | s3TrThreshEntStatus | 0 | 0 | The status of the threshold. The possible values for a write are: addActive(1)...If the entry does not exist, the entry is created… |
1.3.6.1.4.1.45.1.3.3.8.1.1.3 | s3TrThreshEntObject | 0 | 0 | Specifies the part of the concentrator the threshold applies. The possible values are: other(1)..........Unknown threshold (erro… |
1.3.6.1.4.1.45.1.3.3.8.1.1.4 | s3TrThreshEntSlot | 0 | 0 | This object is ONLY meaningful when the object s3TrThreshEntObject has the value port(4). If the object s3TrThreshEntObject has t… |
1.3.6.1.4.1.45.1.3.3.8.1.1.5 | s3TrThreshEntPort | 0 | 0 | This object is ONLY meaningful when the object s3TrThreshEntObject has the value port(4). If the object s3TrThreshEntObject has t… |
1.3.6.1.4.1.45.1.3.3.8.1.1.6 | s3TrThreshEntType | 0 | 0 | Determines which type of threshold applies to this entry. The possible values that can be read and written are listed below. Appl… |
1.3.6.1.4.1.45.1.3.3.8.1.1.7 | s3TrThreshEntCondition | 0 | 0 | Conditions that set off the threshold. The possible values are: other(1)........None of the following crossValue(2)...The value o… |
1.3.6.1.4.1.45.1.3.3.8.1.1.8 | s3TrThreshEntSetValue | 0 | 0 | Threshold setting value. When setting this object the value MUST be greater than zero for the following types of thresholds: lineEr… |
1.3.6.1.4.1.45.1.3.3.8.1.1.9 | s3TrThreshEntActualValue | 0 | 0 | Current value of the threshold counter. This object is set to zero at the begining of each duration window. Notes: 1.) If the ty… |
1.3.6.1.4.1.45.1.3.3.8.1.1.10 | s3TrThreshEntAction | 0 | 0 | Determines what action is to take place if the threshold condition occurs. The possible values that can be read and written are … |
1.3.6.1.4.1.45.1.3.3.8.1.1.11 | s3TrThreshExceedCount | 0 | 0 | Counter for how many times the setted threshold has reached its setting value. |
1.3.6.1.4.1.45.1.3.3.8.1.1.12 | s3TrThreshEntDuration | 0 | 0 | Length of window over which threshold counts are summed, specified in intervals of 500 TimeTicks (i.e., 5 seconds). This window … |