Reference record for OID 1.3.111.2.802.1.1.31.1.3.1.1

Parent
1.3.111.2.802.1.1.31.1.3.1 (ieee8021PSFPFlowMeterTable)
Node code
1
Node name
ieee8021PSFPFlowMeterEntry
Numeric OID
1.3.111.2.802.1.1.31.1.3.1.1
URN notation
urn:oid:1.3.111.2.802.1.1.31.1.3.1.1
ASN.1 notation

{1 3 111 2 802 1 1 31 1 3 1 1}

  • {iso(1) identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1)}
  • {iso(1) identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1)}
  • {iso(1) org(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1)}
  • {iso(1) org(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1)}
OID-IRI notation
  • /1/3/111/2/802/1/1/31/1/3/1/1
  • /ISO/Identified-Organization/111/2/802/1/1/31/1/3/1/1
  • /ISO/3/111/2/802/1/1/31/1/3/1/1
Named path variants
  • /iso/identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry
  • /iso/identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry
  • /iso/org/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry
  • /iso/org/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry
  • /iso/iso-identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry
  • /iso/iso-identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry
  • /iso/iso-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry
  • /iso/iso-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry

Source records

A list of objects that contains the manageable parameters for flow meters for a Bridge component.

Status in source: current.

Names: ieee8021PSFPFlowMeterEntry

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021PSFPFlowMeterEntry",
    "OBJECT-TYPE",
    "SYNTAX",
    "Ieee8021PSFPFlowMeterEntry",
    "MAX-ACCESS",
    "not-accessible",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"A list of objects that contains the manageable parameters for flow meters for a Bridge component.\"",
    "INDEX",
    "{",
    "ieee8021BridgeBaseComponentId",
    ",",
    "ieee8021PSFPFlowMeterInstance",
    "}",
    "::=",
    "{",
    "ieee8021PSFPFlowMeterTable",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "Ieee8021PSFPFlowMeterEntry"
    ],
    null,
    [
      "MaxAccessPart",
      "not-accessible"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "A list of objects that contains the manageable parameters for flow meters for a Bridge component."
    ],
    null,
    null,
    [
      "INDEX",
      [
        [
          0,
          "ieee8021BridgeBaseComponentId"
        ],
        [
          0,
          "ieee8021PSFPFlowMeterInstance"
        ]
      ]
    ],
    null
  ]
}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterEntry.
    Source version and references

    Downloaded: 2026-10-19T00:20:22.458391+00:00. SHA-256: c07683a01effb8ee3c4c2481bef90b80bb260238fd322e13b8e31863cf0d2570

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterEntry OBJECT-TYPE\r\n    SYNTAX      Ieee8021PSFPFlowMeterEntry \r\n    MAX-ACCESS  not-accessible\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "A list of objects that contains the manageable parameters for \r\n        flow meters for a Bridge component."\r\n    INDEX  { ieee8021BridgeBaseComponentId,\r\n             ieee8021PSFPFlowMeterInstance\r\n           }\r\n    ::= { ieee8021PSFPFlowMeterTable 1 }', 'syntax_tree': [['row', 'Ieee8021PSFPFlowMeterEntry'], None, ['MaxAccessPart', 'not-accessible'], ['Status', 'current'], ['DESCRIPTION', 'A list of objects that contains the manageable parameters for flow meters for a Bridge component.'], None, None, ['INDEX', [[0, 'ieee8021BridgeBaseComponentId'], [0, 'ieee8021PSFPFlowMeterInstance']]], None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterEntry.
    Source version and references

    Downloaded: 2026-10-19T00:20:23.281382+00:00. SHA-256: d470a0966348a5a6228febeb0af4fc673e4bc4b06faf9bf7c2793743567635fe

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterEntry OBJECT-TYPE\r\n    SYNTAX      Ieee8021PSFPFlowMeterEntry \r\n    MAX-ACCESS  not-accessible\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "A list of objects that contains the manageable parameters for \r\n        flow meters for a Bridge component."\r\n    INDEX  { ieee8021BridgeBaseComponentId,\r\n             ieee8021PSFPFlowMeterInstance\r\n           }\r\n    ::= { ieee8021PSFPFlowMeterTable 1 }', 'syntax_tree': [['row', 'Ieee8021PSFPFlowMeterEntry'], None, ['MaxAccessPart', 'not-accessible'], ['Status', 'current'], ['DESCRIPTION', 'A list of objects that contains the manageable parameters for flow meters for a Bridge component.'], None, None, ['INDEX', [[0, 'ieee8021BridgeBaseComponentId'], [0, 'ieee8021PSFPFlowMeterInstance']]], None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterEntry.
    Source version and references

    Downloaded: 2026-10-19T00:21:45.476326+00:00. SHA-256: 30b09d38410a4a1bd8e44ab65693c620a6e79a4c143d1bef2891258963fc8716

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterEntry OBJECT-TYPE\n    SYNTAX      Ieee8021PSFPFlowMeterEntry \n    MAX-ACCESS  not-accessible\n    STATUS      current\n    DESCRIPTION\n        "A list of objects that contains the manageable parameters for \n        flow meters for a Bridge component."\n    INDEX  { ieee8021BridgeBaseComponentId,\n             ieee8021PSFPFlowMeterInstance\n           }\n    ::= { ieee8021PSFPFlowMeterTable 1 }', 'syntax_tree': [['row', 'Ieee8021PSFPFlowMeterEntry'], None, ['MaxAccessPart', 'not-accessible'], ['Status', 'current'], ['DESCRIPTION', 'A list of objects that contains the manageable parameters for flow meters for a Bridge component.'], None, None, ['INDEX', [[0, 'ieee8021BridgeBaseComponentId'], [0, 'ieee8021PSFPFlowMeterInstance']]], None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterEntry.
    Source version and references

    Downloaded: 2026-10-19T00:21:46.243340+00:00. SHA-256: 8d8083a2649eaa86555161ed570af77db21fc6b8e5d1f4438fcbaab9ae0e6655

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterEntry OBJECT-TYPE\n    SYNTAX      Ieee8021PSFPFlowMeterEntry \n    MAX-ACCESS  not-accessible\n    STATUS      current\n    DESCRIPTION\n        "A list of objects that contains the manageable parameters for \n        flow meters for a Bridge component."\n    INDEX  { ieee8021BridgeBaseComponentId,\n             ieee8021PSFPFlowMeterInstance\n           }\n    ::= { ieee8021PSFPFlowMeterTable 1 }', 'syntax_tree': [['row', 'Ieee8021PSFPFlowMeterEntry'], None, ['MaxAccessPart', 'not-accessible'], ['Status', 'current'], ['DESCRIPTION', 'A list of objects that contains the manageable parameters for flow meters for a Bridge component.'], None, None, ['INDEX', [[0, 'ieee8021BridgeBaseComponentId'], [0, 'ieee8021PSFPFlowMeterInstance']]], None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterEntry.
    Source version and references

    Downloaded: 2026-10-19T00:21:47.152458+00:00. SHA-256: b81b1e563359d1c24d0cac37f747949d4ecdc92e10ba44859c96d3f39f9532f0

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterEntry OBJECT-TYPE\r\n    SYNTAX      Ieee8021PSFPFlowMeterEntry \r\n    MAX-ACCESS  not-accessible\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "A list of objects that contains the manageable parameters for \r\n        flow meters for a Bridge component."\r\n    INDEX  { ieee8021BridgeBaseComponentId,\r\n             ieee8021PSFPFlowMeterInstance\r\n           }\r\n    ::= { ieee8021PSFPFlowMeterTable 1 }', 'syntax_tree': [['row', 'Ieee8021PSFPFlowMeterEntry'], None, ['MaxAccessPart', 'not-accessible'], ['Status', 'current'], ['DESCRIPTION', 'A list of objects that contains the manageable parameters for flow meters for a Bridge component.'], None, None, ['INDEX', [[0, 'ieee8021BridgeBaseComponentId'], [0, 'ieee8021PSFPFlowMeterInstance']]], None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}

Current Registration Authority (inferred from ancestor 1.3)

Frank Farance

Direct children (11)

OIDNameDirect childrenDescendantsDescription
1.3.111.2.802.1.1.31.1.3.1.1.1 ieee8021PSFPFlowMeterInstance00
1.3.111.2.802.1.1.31.1.3.1.1.2 ieee8021PSFPFlowMeterCIR00
1.3.111.2.802.1.1.31.1.3.1.1.3 ieee8021PSFPFlowMeterCBS00
1.3.111.2.802.1.1.31.1.3.1.1.4 ieee8021PSFPFlowMeterEIR00
1.3.111.2.802.1.1.31.1.3.1.1.5 ieee8021PSFPFlowMeterEBS00
1.3.111.2.802.1.1.31.1.3.1.1.6 ieee8021PSFPFlowMeterCF00
1.3.111.2.802.1.1.31.1.3.1.1.7 ieee8021PSFPFlowMeterCM00
1.3.111.2.802.1.1.31.1.3.1.1.8 ieee8021PSFPFlowMeterDropOnYellow00
1.3.111.2.802.1.1.31.1.3.1.1.9 ieee8021PSFPFlowMeterMarkAllFramesRedEnable00
1.3.111.2.802.1.1.31.1.3.1.1.10 ieee8021PSFPFlowMeterMarkAllFramesRed00
1.3.111.2.802.1.1.31.1.3.1.1.11 ieee8021PSFPFlowMeterEntryRowStatus00