The FlowMeterEBS parameter contains an integer value that represents the EBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.
Status in source: current.
Names: ieee8021PSFPFlowMeterEBS
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ieee8021PSFPFlowMeterEBS",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"The FlowMeterEBS parameter contains an integer value that represents the EBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.\"",
"REFERENCE",
"\"8.6.5.5, 12.31.4\"",
"::=",
"{",
"ieee8021PSFPFlowMeterEntry",
"5",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The FlowMeterEBS parameter contains an integer value that represents the EBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system."
],
[
"REFERENCE",
"8.6.5.5, 12.31.4"
],
null,
null,
null
]
}- IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterEBS.Source version and references
Downloaded: 2026-10-19T00:21:45.476326+00:00. SHA-256:
30b09d38410a4a1bd8e44ab65693c620a6e79a4c143d1bef2891258963fc8716{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterEBS OBJECT-TYPE\n SYNTAX Unsigned32\n MAX-ACCESS read-create\n STATUS current\n DESCRIPTION\n "The FlowMeterEBS parameter contains an integer value that\n represents the EBS value for the flow meter, in octets.\n\n The value of this object MUST be retained across\n reinitializations of the management system."\n REFERENCE "8.6.5.5, 12.31.4"\n ::= { ieee8021PSFPFlowMeterEntry 5}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterEBS parameter contains an integer value that represents the EBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.5, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'} - IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterEBS.Source version and references
Downloaded: 2026-10-19T00:21:46.243340+00:00. SHA-256:
8d8083a2649eaa86555161ed570af77db21fc6b8e5d1f4438fcbaab9ae0e6655{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterEBS OBJECT-TYPE\n SYNTAX Unsigned32\n MAX-ACCESS read-create\n STATUS current\n DESCRIPTION\n "The FlowMeterEBS parameter contains an integer value that\n represents the EBS value for the flow meter, in octets.\n\n The value of this object MUST be retained across\n reinitializations of the management system."\n REFERENCE "8.6.5.5, 12.31.4"\n ::= { ieee8021PSFPFlowMeterEntry 5}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterEBS parameter contains an integer value that represents the EBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.5, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'} - IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterEBS.Source version and references
Downloaded: 2026-10-19T00:21:47.152458+00:00. SHA-256:
b81b1e563359d1c24d0cac37f747949d4ecdc92e10ba44859c96d3f39f9532f0{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterEBS OBJECT-TYPE\r\n SYNTAX Unsigned32\r\n MAX-ACCESS read-create\r\n STATUS current\r\n DESCRIPTION\r\n "The FlowMeterEBS parameter contains an integer value that\r\n represents the EBS value for the flow meter, in octets.\r\n\r\n The value of this object MUST be retained across\r\n reinitializations of the management system."\r\n REFERENCE "8.6.5.5, 12.31.4"\r\n ::= { ieee8021PSFPFlowMeterEntry 5}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterEBS parameter contains an integer value that represents the EBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.5, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}