Reference record for OID 1.3.111.2.802.1.1.31.1.3.1.1.1

Parent
1.3.111.2.802.1.1.31.1.3.1.1 (ieee8021PSFPFlowMeterEntry)
Node code
1
Node name
ieee8021PSFPFlowMeterInstance
Numeric OID
1.3.111.2.802.1.1.31.1.3.1.1.1
URN notation
urn:oid:1.3.111.2.802.1.1.31.1.3.1.1.1
ASN.1 notation

{1 3 111 2 802 1 1 31 1 3 1 1 1}

  • {iso(1) identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterInstance(1)}
  • {iso(1) identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterInstance(1)}
  • {iso(1) org(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterInstance(1)}
  • {iso(1) org(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterInstance(1)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterInstance(1)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterInstance(1)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterInstance(1)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterInstance(1)}
OID-IRI notation
  • /1/3/111/2/802/1/1/31/1/3/1/1/1
  • /ISO/Identified-Organization/111/2/802/1/1/31/1/3/1/1/1
  • /ISO/3/111/2/802/1/1/31/1/3/1/1/1
Named path variants
  • /iso/identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterInstance
  • /iso/identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterInstance
  • /iso/org/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterInstance
  • /iso/org/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterInstance
  • /iso/iso-identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterInstance
  • /iso/iso-identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterInstance
  • /iso/iso-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterInstance
  • /iso/iso-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterInstance

Source records

The FlowMeterInstance parameter is an index into the FlowMeterTable. The value of this object MUST be retained across reinitializations of the management system.

Status in source: current.

Names: ieee8021PSFPFlowMeterInstance

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021PSFPFlowMeterInstance",
    "OBJECT-TYPE",
    "SYNTAX",
    "Unsigned32",
    "MAX-ACCESS",
    "not-accessible",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The FlowMeterInstance parameter is an index into the FlowMeterTable. The value of this object MUST be retained across reinitializations of the management system.\"",
    "REFERENCE",
    "\"8.6.5.1, 12.31.4\"",
    "::=",
    "{",
    "ieee8021PSFPFlowMeterEntry",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "ApplicationSyntax",
      "Unsigned32"
    ],
    null,
    [
      "MaxAccessPart",
      "not-accessible"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The FlowMeterInstance parameter is an index into the FlowMeterTable. The value of this object MUST be retained across reinitializations of the management system."
    ],
    [
      "REFERENCE",
      "8.6.5.1, 12.31.4"
    ],
    null,
    null,
    null
  ]
}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterInstance.
    Source version and references

    Downloaded: 2026-10-19T00:20:22.458391+00:00. SHA-256: c07683a01effb8ee3c4c2481bef90b80bb260238fd322e13b8e31863cf0d2570

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterInstance OBJECT-TYPE\r\n    SYNTAX      Unsigned32\r\n    MAX-ACCESS  not-accessible\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "The FlowMeterInstance parameter is an index into the \r\n        FlowMeterTable.\r\n\r\n        The value of this object MUST be retained across\r\n        reinitializations of the management system."\r\n    REFERENCE   "8.6.5.1, 12.31.4"\r\n    ::= { ieee8021PSFPFlowMeterEntry 1}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'not-accessible'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterInstance parameter is an index into the FlowMeterTable. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.1, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterInstance.
    Source version and references

    Downloaded: 2026-10-19T00:20:23.281382+00:00. SHA-256: d470a0966348a5a6228febeb0af4fc673e4bc4b06faf9bf7c2793743567635fe

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterInstance OBJECT-TYPE\r\n    SYNTAX      Unsigned32\r\n    MAX-ACCESS  not-accessible\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "The FlowMeterInstance parameter is an index into the \r\n        FlowMeterTable.\r\n\r\n        The value of this object MUST be retained across\r\n        reinitializations of the management system."\r\n    REFERENCE   "8.6.5.1, 12.31.4"\r\n    ::= { ieee8021PSFPFlowMeterEntry 1}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'not-accessible'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterInstance parameter is an index into the FlowMeterTable. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.1, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}

The FlowMeterInstance parameter is an index into the FlowMeterTable. The value of this object MUST be retained across reinitializations of the management system.

Status in source: current.

Names: ieee8021PSFPFlowMeterInstance

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021PSFPFlowMeterInstance",
    "OBJECT-TYPE",
    "SYNTAX",
    "Unsigned32",
    "MAX-ACCESS",
    "not-accessible",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The FlowMeterInstance parameter is an index into the FlowMeterTable. The value of this object MUST be retained across reinitializations of the management system.\"",
    "REFERENCE",
    "\"8.6.5.5, 12.31.4\"",
    "::=",
    "{",
    "ieee8021PSFPFlowMeterEntry",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "ApplicationSyntax",
      "Unsigned32"
    ],
    null,
    [
      "MaxAccessPart",
      "not-accessible"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The FlowMeterInstance parameter is an index into the FlowMeterTable. The value of this object MUST be retained across reinitializations of the management system."
    ],
    [
      "REFERENCE",
      "8.6.5.5, 12.31.4"
    ],
    null,
    null,
    null
  ]
}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterInstance.
    Source version and references

    Downloaded: 2026-10-19T00:21:45.476326+00:00. SHA-256: 30b09d38410a4a1bd8e44ab65693c620a6e79a4c143d1bef2891258963fc8716

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterInstance OBJECT-TYPE\n    SYNTAX      Unsigned32\n    MAX-ACCESS  not-accessible\n    STATUS      current\n    DESCRIPTION\n        "The FlowMeterInstance parameter is an index into the \n        FlowMeterTable.\n\n        The value of this object MUST be retained across\n        reinitializations of the management system."\n    REFERENCE   "8.6.5.5, 12.31.4"\n    ::= { ieee8021PSFPFlowMeterEntry 1}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'not-accessible'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterInstance parameter is an index into the FlowMeterTable. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.5, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterInstance.
    Source version and references

    Downloaded: 2026-10-19T00:21:46.243340+00:00. SHA-256: 8d8083a2649eaa86555161ed570af77db21fc6b8e5d1f4438fcbaab9ae0e6655

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterInstance OBJECT-TYPE\n    SYNTAX      Unsigned32\n    MAX-ACCESS  not-accessible\n    STATUS      current\n    DESCRIPTION\n        "The FlowMeterInstance parameter is an index into the \n        FlowMeterTable.\n\n        The value of this object MUST be retained across\n        reinitializations of the management system."\n    REFERENCE   "8.6.5.5, 12.31.4"\n    ::= { ieee8021PSFPFlowMeterEntry 1}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'not-accessible'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterInstance parameter is an index into the FlowMeterTable. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.5, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterInstance.
    Source version and references

    Downloaded: 2026-10-19T00:21:47.152458+00:00. SHA-256: b81b1e563359d1c24d0cac37f747949d4ecdc92e10ba44859c96d3f39f9532f0

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterInstance OBJECT-TYPE\r\n    SYNTAX      Unsigned32\r\n    MAX-ACCESS  not-accessible\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "The FlowMeterInstance parameter is an index into the \r\n        FlowMeterTable.\r\n\r\n        The value of this object MUST be retained across\r\n        reinitializations of the management system."\r\n    REFERENCE   "8.6.5.5, 12.31.4"\r\n    ::= { ieee8021PSFPFlowMeterEntry 1}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'not-accessible'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterInstance parameter is an index into the FlowMeterTable. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.5, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}

Current Registration Authority (inferred from ancestor 1.3)

Frank Farance

Siblings (10)

OIDNameDirect childrenDescendantsDescription
1.3.111.2.802.1.1.31.1.3.1.1.2 ieee8021PSFPFlowMeterCIR00
1.3.111.2.802.1.1.31.1.3.1.1.3 ieee8021PSFPFlowMeterCBS00
1.3.111.2.802.1.1.31.1.3.1.1.4 ieee8021PSFPFlowMeterEIR00
1.3.111.2.802.1.1.31.1.3.1.1.5 ieee8021PSFPFlowMeterEBS00
1.3.111.2.802.1.1.31.1.3.1.1.6 ieee8021PSFPFlowMeterCF00
1.3.111.2.802.1.1.31.1.3.1.1.7 ieee8021PSFPFlowMeterCM00
1.3.111.2.802.1.1.31.1.3.1.1.8 ieee8021PSFPFlowMeterDropOnYellow00
1.3.111.2.802.1.1.31.1.3.1.1.9 ieee8021PSFPFlowMeterMarkAllFramesRedEnable00
1.3.111.2.802.1.1.31.1.3.1.1.10 ieee8021PSFPFlowMeterMarkAllFramesRed00
1.3.111.2.802.1.1.31.1.3.1.1.11 ieee8021PSFPFlowMeterEntryRowStatus00