The FlowMeterMarkAllFramesRedEnable parameter contains a Boolean value that indicates whether the MarkAllFramesRed function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.
Status in source: current.
Names: ieee8021PSFPFlowMeterMarkAllFramesRedEnable
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ieee8021PSFPFlowMeterMarkAllFramesRedEnable",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"The FlowMeterMarkAllFramesRedEnable parameter contains a Boolean value that indicates whether the MarkAllFramesRed function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.\"",
"REFERENCE",
"\"8.6.5.1, 8.6.5.1.3, 12.31.4\"",
"DEFVAL",
"{",
"false",
"}",
"::=",
"{",
"ieee8021PSFPFlowMeterEntry",
"9",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The FlowMeterMarkAllFramesRedEnable parameter contains a Boolean value that indicates whether the MarkAllFramesRed function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system."
],
[
"REFERENCE",
"8.6.5.1, 8.6.5.1.3, 12.31.4"
],
null,
null,
[
"DEFVAL",
"false"
]
]
}- IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterMarkAllFramesRedEnable.Source version and references
Downloaded: 2026-10-19T00:20:22.458391+00:00. SHA-256:
c07683a01effb8ee3c4c2481bef90b80bb260238fd322e13b8e31863cf0d2570{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterMarkAllFramesRedEnable OBJECT-TYPE\r\n SYNTAX TruthValue\r\n MAX-ACCESS read-create\r\n STATUS current\r\n DESCRIPTION\r\n "The FlowMeterMarkAllFramesRedEnable parameter contains\r\n a Boolean value that indicates whether the MarkAllFramesRed\r\n function is enabled (TRUE) or disabled (FALSE).\r\n\r\n The value of this object MUST be retained across\r\n reinitializations of the management system."\r\n REFERENCE "8.6.5.1, 8.6.5.1.3, 12.31.4"\r\n DEFVAL { false }\r\n ::= { ieee8021PSFPFlowMeterEntry 9}', 'syntax_tree': [['row', 'TruthValue'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterMarkAllFramesRedEnable parameter contains a Boolean value that indicates whether the MarkAllFramesRed function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.1, 8.6.5.1.3, 12.31.4'], None, None, ['DEFVAL', 'false']], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'} - IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterMarkAllFramesRedEnable.Source version and references
Downloaded: 2026-10-19T00:20:23.281382+00:00. SHA-256:
d470a0966348a5a6228febeb0af4fc673e4bc4b06faf9bf7c2793743567635fe{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterMarkAllFramesRedEnable OBJECT-TYPE\r\n SYNTAX TruthValue\r\n MAX-ACCESS read-create\r\n STATUS current\r\n DESCRIPTION\r\n "The FlowMeterMarkAllFramesRedEnable parameter contains\r\n a Boolean value that indicates whether the MarkAllFramesRed\r\n function is enabled (TRUE) or disabled (FALSE).\r\n\r\n The value of this object MUST be retained across\r\n reinitializations of the management system."\r\n REFERENCE "8.6.5.1, 8.6.5.1.3, 12.31.4"\r\n DEFVAL { false }\r\n ::= { ieee8021PSFPFlowMeterEntry 9}', 'syntax_tree': [['row', 'TruthValue'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterMarkAllFramesRedEnable parameter contains a Boolean value that indicates whether the MarkAllFramesRed function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.1, 8.6.5.1.3, 12.31.4'], None, None, ['DEFVAL', 'false']], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}