Reference record for OID 1.3.111.2.802.1.1.31.1.3.1.1.4

Parent
1.3.111.2.802.1.1.31.1.3.1.1 (ieee8021PSFPFlowMeterEntry)
Node code
4
Node name
ieee8021PSFPFlowMeterEIR
Numeric OID
1.3.111.2.802.1.1.31.1.3.1.1.4
URN notation
urn:oid:1.3.111.2.802.1.1.31.1.3.1.1.4
ASN.1 notation

{1 3 111 2 802 1 1 31 1 3 1 1 4}

  • {iso(1) identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterEIR(4)}
  • {iso(1) identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterEIR(4)}
  • {iso(1) org(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterEIR(4)}
  • {iso(1) org(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterEIR(4)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterEIR(4)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterEIR(4)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterEIR(4)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterEIR(4)}
OID-IRI notation
  • /1/3/111/2/802/1/1/31/1/3/1/1/4
  • /ISO/Identified-Organization/111/2/802/1/1/31/1/3/1/1/4
  • /ISO/3/111/2/802/1/1/31/1/3/1/1/4
Named path variants
  • /iso/identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterEIR
  • /iso/identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterEIR
  • /iso/org/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterEIR
  • /iso/org/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterEIR
  • /iso/iso-identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterEIR
  • /iso/iso-identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterEIR
  • /iso/iso-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterEIR
  • /iso/iso-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterEIR

Source records

The FlowMeterEIR parameter contains an integer value that represents the EIR value for the flow meter, in bit/second. The value of this object MUST be retained across reinitializations of the management system.

Status in source: current.

Names: ieee8021PSFPFlowMeterEIR

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021PSFPFlowMeterEIR",
    "OBJECT-TYPE",
    "SYNTAX",
    "Unsigned32",
    "MAX-ACCESS",
    "read-create",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The FlowMeterEIR parameter contains an integer value that represents the EIR value for the flow meter, in bit/second. The value of this object MUST be retained across reinitializations of the management system.\"",
    "REFERENCE",
    "\"8.6.5.1, 12.31.4\"",
    "::=",
    "{",
    "ieee8021PSFPFlowMeterEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "ApplicationSyntax",
      "Unsigned32"
    ],
    null,
    [
      "MaxAccessPart",
      "read-create"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The FlowMeterEIR parameter contains an integer value that represents the EIR value for the flow meter, in bit/second. The value of this object MUST be retained across reinitializations of the management system."
    ],
    [
      "REFERENCE",
      "8.6.5.1, 12.31.4"
    ],
    null,
    null,
    null
  ]
}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterEIR.
    Source version and references

    Downloaded: 2026-10-19T00:20:23.281382+00:00. SHA-256: d470a0966348a5a6228febeb0af4fc673e4bc4b06faf9bf7c2793743567635fe

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterEIR OBJECT-TYPE\r\n    SYNTAX      Unsigned32\r\n    MAX-ACCESS  read-create\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "The FlowMeterEIR parameter contains an integer value that\r\n        represents the EIR value for the flow meter, in bit/second.\r\n\r\n        The value of this object MUST be retained across\r\n        reinitializations of the management system."\r\n    REFERENCE   "8.6.5.1, 12.31.4"\r\n    ::= { ieee8021PSFPFlowMeterEntry 4}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterEIR parameter contains an integer value that represents the EIR value for the flow meter, in bit/second. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.1, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}

The FlowMeterEIR parameter contains an integer value that represents the EIR value for the flow meter, in bit/s. The value of this object MUST be retained across reinitializations of the management system.

Status in source: current.

Names: ieee8021PSFPFlowMeterEIR

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021PSFPFlowMeterEIR",
    "OBJECT-TYPE",
    "SYNTAX",
    "Unsigned32",
    "MAX-ACCESS",
    "read-create",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The FlowMeterEIR parameter contains an integer value that represents the EIR value for the flow meter, in bit/s. The value of this object MUST be retained across reinitializations of the management system.\"",
    "REFERENCE",
    "\"8.6.5.1, 12.31.4\"",
    "::=",
    "{",
    "ieee8021PSFPFlowMeterEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "ApplicationSyntax",
      "Unsigned32"
    ],
    null,
    [
      "MaxAccessPart",
      "read-create"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The FlowMeterEIR parameter contains an integer value that represents the EIR value for the flow meter, in bit/s. The value of this object MUST be retained across reinitializations of the management system."
    ],
    [
      "REFERENCE",
      "8.6.5.1, 12.31.4"
    ],
    null,
    null,
    null
  ]
}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterEIR.
    Source version and references

    Downloaded: 2026-10-19T00:20:22.458391+00:00. SHA-256: c07683a01effb8ee3c4c2481bef90b80bb260238fd322e13b8e31863cf0d2570

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterEIR OBJECT-TYPE\r\n    SYNTAX      Unsigned32\r\n    MAX-ACCESS  read-create\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "The FlowMeterEIR parameter contains an integer value that\r\n        represents the EIR value for the flow meter, in bit/s.\r\n\r\n        The value of this object MUST be retained across\r\n        reinitializations of the management system."\r\n    REFERENCE   "8.6.5.1, 12.31.4"\r\n    ::= { ieee8021PSFPFlowMeterEntry 4}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterEIR parameter contains an integer value that represents the EIR value for the flow meter, in bit/s. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.1, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}

The FlowMeterEIR parameter contains an integer value that represents the EIR value for the flow meter, in bit/second. The value of this object MUST be retained across reinitializations of the management system.

Status in source: current.

Names: ieee8021PSFPFlowMeterEIR

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021PSFPFlowMeterEIR",
    "OBJECT-TYPE",
    "SYNTAX",
    "Unsigned32",
    "MAX-ACCESS",
    "read-create",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The FlowMeterEIR parameter contains an integer value that represents the EIR value for the flow meter, in bit/second. The value of this object MUST be retained across reinitializations of the management system.\"",
    "REFERENCE",
    "\"8.6.5.5, 12.31.4\"",
    "::=",
    "{",
    "ieee8021PSFPFlowMeterEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "ApplicationSyntax",
      "Unsigned32"
    ],
    null,
    [
      "MaxAccessPart",
      "read-create"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The FlowMeterEIR parameter contains an integer value that represents the EIR value for the flow meter, in bit/second. The value of this object MUST be retained across reinitializations of the management system."
    ],
    [
      "REFERENCE",
      "8.6.5.5, 12.31.4"
    ],
    null,
    null,
    null
  ]
}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterEIR.
    Source version and references

    Downloaded: 2026-10-19T00:21:45.476326+00:00. SHA-256: 30b09d38410a4a1bd8e44ab65693c620a6e79a4c143d1bef2891258963fc8716

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterEIR OBJECT-TYPE\n    SYNTAX      Unsigned32\n    MAX-ACCESS  read-create\n    STATUS      current\n    DESCRIPTION\n        "The FlowMeterEIR parameter contains an integer value that\n        represents the EIR value for the flow meter, in bit/second.\n\n        The value of this object MUST be retained across\n        reinitializations of the management system."\n    REFERENCE   "8.6.5.5, 12.31.4"\n    ::= { ieee8021PSFPFlowMeterEntry 4}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterEIR parameter contains an integer value that represents the EIR value for the flow meter, in bit/second. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.5, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterEIR.
    Source version and references

    Downloaded: 2026-10-19T00:21:46.243340+00:00. SHA-256: 8d8083a2649eaa86555161ed570af77db21fc6b8e5d1f4438fcbaab9ae0e6655

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterEIR OBJECT-TYPE\n    SYNTAX      Unsigned32\n    MAX-ACCESS  read-create\n    STATUS      current\n    DESCRIPTION\n        "The FlowMeterEIR parameter contains an integer value that\n        represents the EIR value for the flow meter, in bit/second.\n\n        The value of this object MUST be retained across\n        reinitializations of the management system."\n    REFERENCE   "8.6.5.5, 12.31.4"\n    ::= { ieee8021PSFPFlowMeterEntry 4}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterEIR parameter contains an integer value that represents the EIR value for the flow meter, in bit/second. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.5, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterEIR.
    Source version and references

    Downloaded: 2026-10-19T00:21:47.152458+00:00. SHA-256: b81b1e563359d1c24d0cac37f747949d4ecdc92e10ba44859c96d3f39f9532f0

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterEIR OBJECT-TYPE\r\n    SYNTAX      Unsigned32\r\n    MAX-ACCESS  read-create\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "The FlowMeterEIR parameter contains an integer value that\r\n        represents the EIR value for the flow meter, in bit/second.\r\n\r\n        The value of this object MUST be retained across\r\n        reinitializations of the management system."\r\n    REFERENCE   "8.6.5.5, 12.31.4"\r\n    ::= { ieee8021PSFPFlowMeterEntry 4}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterEIR parameter contains an integer value that represents the EIR value for the flow meter, in bit/second. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.5, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}

Current Registration Authority (inferred from ancestor 1.3)

Frank Farance

Siblings (10)

OIDNameDirect childrenDescendantsDescription
1.3.111.2.802.1.1.31.1.3.1.1.1 ieee8021PSFPFlowMeterInstance00
1.3.111.2.802.1.1.31.1.3.1.1.2 ieee8021PSFPFlowMeterCIR00
1.3.111.2.802.1.1.31.1.3.1.1.3 ieee8021PSFPFlowMeterCBS00
1.3.111.2.802.1.1.31.1.3.1.1.5 ieee8021PSFPFlowMeterEBS00
1.3.111.2.802.1.1.31.1.3.1.1.6 ieee8021PSFPFlowMeterCF00
1.3.111.2.802.1.1.31.1.3.1.1.7 ieee8021PSFPFlowMeterCM00
1.3.111.2.802.1.1.31.1.3.1.1.8 ieee8021PSFPFlowMeterDropOnYellow00
1.3.111.2.802.1.1.31.1.3.1.1.9 ieee8021PSFPFlowMeterMarkAllFramesRedEnable00
1.3.111.2.802.1.1.31.1.3.1.1.10 ieee8021PSFPFlowMeterMarkAllFramesRed00
1.3.111.2.802.1.1.31.1.3.1.1.11 ieee8021PSFPFlowMeterEntryRowStatus00