The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.
Status in source: current.
Names: ieee8021PSFPFlowMeterCBS
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ieee8021PSFPFlowMeterCBS",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.\"",
"REFERENCE",
"\"8.6.5.5, 12.31.4\"",
"::=",
"{",
"ieee8021PSFPFlowMeterEntry",
"3",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system."
],
[
"REFERENCE",
"8.6.5.5, 12.31.4"
],
null,
null,
null
]
}- IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterCBS.Source version and references
Downloaded: 2026-10-19T00:21:45.476326+00:00. SHA-256:
30b09d38410a4a1bd8e44ab65693c620a6e79a4c143d1bef2891258963fc8716{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterCBS OBJECT-TYPE\n SYNTAX Unsigned32\n MAX-ACCESS read-create\n STATUS current\n DESCRIPTION\n "The FlowMeterCBS parameter contains an integer value that\n represents the CBS value for the flow meter, in octets.\n\n The value of this object MUST be retained across\n reinitializations of the management system."\n REFERENCE "8.6.5.5, 12.31.4"\n ::= { ieee8021PSFPFlowMeterEntry 3}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.5, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'} - IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterCBS.Source version and references
Downloaded: 2026-10-19T00:21:46.243340+00:00. SHA-256:
8d8083a2649eaa86555161ed570af77db21fc6b8e5d1f4438fcbaab9ae0e6655{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterCBS OBJECT-TYPE\n SYNTAX Unsigned32\n MAX-ACCESS read-create\n STATUS current\n DESCRIPTION\n "The FlowMeterCBS parameter contains an integer value that\n represents the CBS value for the flow meter, in octets.\n\n The value of this object MUST be retained across\n reinitializations of the management system."\n REFERENCE "8.6.5.5, 12.31.4"\n ::= { ieee8021PSFPFlowMeterEntry 3}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.5, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'} - IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterCBS.Source version and references
Downloaded: 2026-10-19T00:21:47.152458+00:00. SHA-256:
b81b1e563359d1c24d0cac37f747949d4ecdc92e10ba44859c96d3f39f9532f0{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterCBS OBJECT-TYPE\r\n SYNTAX Unsigned32\r\n MAX-ACCESS read-create\r\n STATUS current\r\n DESCRIPTION\r\n "The FlowMeterCBS parameter contains an integer value that\r\n represents the CBS value for the flow meter, in octets.\r\n\r\n The value of this object MUST be retained across\r\n reinitializations of the management system."\r\n REFERENCE "8.6.5.5, 12.31.4"\r\n ::= { ieee8021PSFPFlowMeterEntry 3}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.5, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}