Reference record for OID 1.3.111.2.802.1.1.31.1.3.1.1.3

Parent
1.3.111.2.802.1.1.31.1.3.1.1 (ieee8021PSFPFlowMeterEntry)
Node code
3
Node name
ieee8021PSFPFlowMeterCBS
Numeric OID
1.3.111.2.802.1.1.31.1.3.1.1.3
URN notation
urn:oid:1.3.111.2.802.1.1.31.1.3.1.1.3
ASN.1 notation

{1 3 111 2 802 1 1 31 1 3 1 1 3}

  • {iso(1) identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterCBS(3)}
  • {iso(1) identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterCBS(3)}
  • {iso(1) org(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterCBS(3)}
  • {iso(1) org(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterCBS(3)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterCBS(3)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterCBS(3)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterCBS(3)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPFlowMeterParameters(3) ieee8021PSFPFlowMeterTable(1) ieee8021PSFPFlowMeterEntry(1) ieee8021PSFPFlowMeterCBS(3)}
OID-IRI notation
  • /1/3/111/2/802/1/1/31/1/3/1/1/3
  • /ISO/Identified-Organization/111/2/802/1/1/31/1/3/1/1/3
  • /ISO/3/111/2/802/1/1/31/1/3/1/1/3
Named path variants
  • /iso/identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterCBS
  • /iso/identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterCBS
  • /iso/org/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterCBS
  • /iso/org/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterCBS
  • /iso/iso-identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterCBS
  • /iso/iso-identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterCBS
  • /iso/iso-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterCBS
  • /iso/iso-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPFlowMeterParameters/ieee8021PSFPFlowMeterTable/ieee8021PSFPFlowMeterEntry/ieee8021PSFPFlowMeterCBS

Source records

The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.

Status in source: current.

Names: ieee8021PSFPFlowMeterCBS

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021PSFPFlowMeterCBS",
    "OBJECT-TYPE",
    "SYNTAX",
    "Unsigned32",
    "MAX-ACCESS",
    "read-create",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.\"",
    "REFERENCE",
    "\"8.6.5.5, 12.31.4\"",
    "::=",
    "{",
    "ieee8021PSFPFlowMeterEntry",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "ApplicationSyntax",
      "Unsigned32"
    ],
    null,
    [
      "MaxAccessPart",
      "read-create"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system."
    ],
    [
      "REFERENCE",
      "8.6.5.5, 12.31.4"
    ],
    null,
    null,
    null
  ]
}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterCBS.
    Source version and references

    Downloaded: 2026-10-19T00:21:45.476326+00:00. SHA-256: 30b09d38410a4a1bd8e44ab65693c620a6e79a4c143d1bef2891258963fc8716

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterCBS OBJECT-TYPE\n    SYNTAX      Unsigned32\n    MAX-ACCESS  read-create\n    STATUS      current\n    DESCRIPTION\n        "The FlowMeterCBS parameter contains an integer value that\n        represents the CBS value for the flow meter, in octets.\n\n        The value of this object MUST be retained across\n        reinitializations of the management system."\n    REFERENCE   "8.6.5.5, 12.31.4"\n    ::= { ieee8021PSFPFlowMeterEntry 3}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.5, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterCBS.
    Source version and references

    Downloaded: 2026-10-19T00:21:46.243340+00:00. SHA-256: 8d8083a2649eaa86555161ed570af77db21fc6b8e5d1f4438fcbaab9ae0e6655

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterCBS OBJECT-TYPE\n    SYNTAX      Unsigned32\n    MAX-ACCESS  read-create\n    STATUS      current\n    DESCRIPTION\n        "The FlowMeterCBS parameter contains an integer value that\n        represents the CBS value for the flow meter, in octets.\n\n        The value of this object MUST be retained across\n        reinitializations of the management system."\n    REFERENCE   "8.6.5.5, 12.31.4"\n    ::= { ieee8021PSFPFlowMeterEntry 3}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.5, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterCBS.
    Source version and references

    Downloaded: 2026-10-19T00:21:47.152458+00:00. SHA-256: b81b1e563359d1c24d0cac37f747949d4ecdc92e10ba44859c96d3f39f9532f0

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterCBS OBJECT-TYPE\r\n    SYNTAX      Unsigned32\r\n    MAX-ACCESS  read-create\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "The FlowMeterCBS parameter contains an integer value that\r\n        represents the CBS value for the flow meter, in octets.\r\n\r\n        The value of this object MUST be retained across\r\n        reinitializations of the management system."\r\n    REFERENCE   "8.6.5.5, 12.31.4"\r\n    ::= { ieee8021PSFPFlowMeterEntry 3}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.5, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}

The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.

Status in source: current.

Names: ieee8021PSFPFlowMeterCBS

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021PSFPFlowMeterCBS",
    "OBJECT-TYPE",
    "SYNTAX",
    "Unsigned32",
    "MAX-ACCESS",
    "read-create",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.\"",
    "REFERENCE",
    "\"8.6.5.1, 12.31.4\"",
    "::=",
    "{",
    "ieee8021PSFPFlowMeterEntry",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "ApplicationSyntax",
      "Unsigned32"
    ],
    null,
    [
      "MaxAccessPart",
      "read-create"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system."
    ],
    [
      "REFERENCE",
      "8.6.5.1, 12.31.4"
    ],
    null,
    null,
    null
  ]
}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterCBS.
    Source version and references

    Downloaded: 2026-10-19T00:20:22.458391+00:00. SHA-256: c07683a01effb8ee3c4c2481bef90b80bb260238fd322e13b8e31863cf0d2570

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterCBS OBJECT-TYPE\r\n    SYNTAX      Unsigned32\r\n    MAX-ACCESS  read-create\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "The FlowMeterCBS parameter contains an integer value that\r\n        represents the CBS value for the flow meter, in octets.\r\n\r\n        The value of this object MUST be retained across\r\n        reinitializations of the management system."\r\n    REFERENCE   "8.6.5.1, 12.31.4"\r\n    ::= { ieee8021PSFPFlowMeterEntry 3}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.1, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPFlowMeterCBS.
    Source version and references

    Downloaded: 2026-10-19T00:20:23.281382+00:00. SHA-256: d470a0966348a5a6228febeb0af4fc673e4bc4b06faf9bf7c2793743567635fe

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPFlowMeterCBS OBJECT-TYPE\r\n    SYNTAX      Unsigned32\r\n    MAX-ACCESS  read-create\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "The FlowMeterCBS parameter contains an integer value that\r\n        represents the CBS value for the flow meter, in octets.\r\n\r\n        The value of this object MUST be retained across\r\n        reinitializations of the management system."\r\n    REFERENCE   "8.6.5.1, 12.31.4"\r\n    ::= { ieee8021PSFPFlowMeterEntry 3}', 'syntax_tree': [['ApplicationSyntax', 'Unsigned32'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The FlowMeterCBS parameter contains an integer value that represents the CBS value for the flow meter, in octets. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.1, 12.31.4'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}

Current Registration Authority (inferred from ancestor 1.3)

Frank Farance

Siblings (10)

OIDNameDirect childrenDescendantsDescription
1.3.111.2.802.1.1.31.1.3.1.1.1 ieee8021PSFPFlowMeterInstance00
1.3.111.2.802.1.1.31.1.3.1.1.2 ieee8021PSFPFlowMeterCIR00
1.3.111.2.802.1.1.31.1.3.1.1.4 ieee8021PSFPFlowMeterEIR00
1.3.111.2.802.1.1.31.1.3.1.1.5 ieee8021PSFPFlowMeterEBS00
1.3.111.2.802.1.1.31.1.3.1.1.6 ieee8021PSFPFlowMeterCF00
1.3.111.2.802.1.1.31.1.3.1.1.7 ieee8021PSFPFlowMeterCM00
1.3.111.2.802.1.1.31.1.3.1.1.8 ieee8021PSFPFlowMeterDropOnYellow00
1.3.111.2.802.1.1.31.1.3.1.1.9 ieee8021PSFPFlowMeterMarkAllFramesRedEnable00
1.3.111.2.802.1.1.31.1.3.1.1.10 ieee8021PSFPFlowMeterMarkAllFramesRed00
1.3.111.2.802.1.1.31.1.3.1.1.11 ieee8021PSFPFlowMeterEntryRowStatus00