OID reference

unitTimeSourceCommanded

1.3.6.1.4.1.1206.4.2.1.3.22.3

Description

<Definition> Commands the unit to the primary source for adjusting the unit clock: other: the source of the unit time is not defined by this standard. lineSync: the source of the unit time is determined by tracking the (AC) power line frequency rtcSqwr: the source of the unit time a Real Time Clock Square Wave output …

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.2.1.3.22 (ascClock)
Node code
3
Node name
unitTimeSourceCommanded
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.2.1.3.22.3
URN notation
urn:oid:1.3.6.1.4.1.1206.4.2.1.3.22.3
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 2 1 3 22 3}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) ascClock(22) unitTimeSourceCommanded(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) ascClock(22) unitTimeSourceCommanded(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) ascClock(22) unitTimeSourceCommanded(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) ascClock(22) unitTimeSourceCommanded(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) ascClock(22) unitTimeSourceCommanded(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) ascClock(22) unitTimeSourceCommanded(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) ascClock(22) unitTimeSourceCommanded(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) ascClock(22) unitTimeSourceCommanded(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) ascClock(22) unitTimeSourceCommanded(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) ascClock(22) unitTimeSourceCommanded(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) ascClock(22) unitTimeSourceCommanded(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) ascClock(22) unitTimeSourceCommanded(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) ascClock(22) unitTimeSourceCommanded(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) ascClock(22) unitTimeSourceCommanded(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) ascClock(22) unitTimeSourceCommanded(3)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) unit(3) ascClock(22) unitTimeSourceCommanded(3)}
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/2/1/3/22/3
  • /ISO/Identified-Organization/6/1/4/1/1206/4/2/1/3/22/3
  • /ISO/3/6/1/4/1/1206/4/2/1/3/22/3
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/asc/unit/ascClock/unitTimeSourceCommanded
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/asc/unit/ascClock/unitTimeSourceCommanded
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/asc/unit/ascClock/unitTimeSourceCommanded
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/asc/unit/ascClock/unitTimeSourceCommanded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/devices/asc/unit/ascClock/unitTimeSourceCommanded
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/devices/asc/unit/ascClock/unitTimeSourceCommanded
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/devices/asc/unit/ascClock/unitTimeSourceCommanded
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/devices/asc/unit/ascClock/unitTimeSourceCommanded
  • /iso/org/dod/internet/private/enterprise/1206/transportation/devices/asc/unit/ascClock/unitTimeSourceCommanded
  • /iso/org/dod/internet/private/enterprise/nema/transportation/devices/asc/unit/ascClock/unitTimeSourceCommanded
  • /iso/org/dod/internet/private/enterprises/1206/transportation/devices/asc/unit/ascClock/unitTimeSourceCommanded
  • /iso/org/dod/internet/private/enterprises/nema/transportation/devices/asc/unit/ascClock/unitTimeSourceCommanded
  • /iso/org/dod/internet/private/ldap-enterprise/1206/transportation/devices/asc/unit/ascClock/unitTimeSourceCommanded
  • /iso/org/dod/internet/private/ldap-enterprise/nema/transportation/devices/asc/unit/ascClock/unitTimeSourceCommanded
  • /iso/org/dod/internet/private/vendor-objects/1206/transportation/devices/asc/unit/ascClock/unitTimeSourceCommanded
  • /iso/org/dod/internet/private/vendor-objects/nema/transportation/devices/asc/unit/ascClock/unitTimeSourceCommanded
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory
Default value
lineSync

Enumerated values

ValueName
1other
2lineSync
3rtcSqwr
4crystal
5gnss
6ntp

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.1206.4.2.1.3.22.3.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

unitTimeSourceCommanded · mandatory

unitTimeSourceCommanded    OBJECT-TYPE
      SYNTAX    INTEGER { other (1),
             lineSync (2),
             rtcSqwr (3),
             crystal (4),
             gnss (5),
             ntp (6) }



                                                                                    

                                                                                    
                                                                                   

      ACCESS       read-write
      STATUS       mandatory
      DESCRIPTION "<Definition> Commands the unit to the primary source for
             adjusting the unit clock:
             other: the source of the unit time is not defined by this
                   standard.
             lineSync: the source of the unit time is determined by tracking
                   the (AC) power line frequency
             rtcSqwr: the source of the unit time a Real Time Clock Square
                   Wave output
             crystal: the source of the unit time is the internal crystal.
                   This might also be used if the unit time normally uses line
                   frequency but appears to be drifting too much as might
                   happen when on a power generator.
             gnss: a GNSS device is being used to update the unit's internal
                   reference on a frequent basis (e.g., once per minute))
             ntp: the network time protocol (NTP) is being used to update the
                   unit's internal reference
      <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.22.3
      <Object Type> P"
      DEFVAL { lineSync }
::= { ascClock 3 }

unitTimeSourceCommanded · mandatory

unitTimeSourceCommanded    OBJECT-TYPE
      SYNTAX    INTEGER { other (1),
             lineSync (2),
             rtcSqwr (3),
             crystal (4),
             gnss (5),
             ntp (6) }
      ACCESS       read-write
      STATUS       mandatory
      DESCRIPTION "<Definition> Commands the unit to the primary source for
             adjusting the unit clock:
             other: the source of the unit time is not defined by this
                   standard.
             lineSync: the source of the unit time is determined by tracking
                   the (AC) power line frequency
             rtcSqwr: the source of the unit time a Real Time Clock Square
                   Wave output
             crystal: the source of the unit time is the internal crystal.
                   This might also be used if the unit time normally uses line
                   frequency but appears to be drifting too much as might
                   happen when on a power generator.
             gnss: a GNSS device is being used to update the unit's internal
                   reference on a frequent basis (e.g., once per minute))
             ntp: the network time protocol (NTP) is being used to update the
                   unit's internal reference
      <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.22.3"
      DEFVAL { lineSync }
::= { ascClock 3 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

<Definition> Commands the unit to the primary source for adjusting the unit clock: other: the source of the unit time is not defined by this standard. lineSync: the source of the unit time is determined by tracking the (AC) power line frequency rtcSqwr: the source of the unit time a Real Time Clock Square Wave output crystal: the source of the unit time is the internal crystal. This might also be used if the unit time normally uses line frequency but appears to be drifting too much as might happen when on a power generator. gnss: a GNSS device is being used to update the unit's internal reference on a frequent basis (e.g., once per minute)) ntp: the network time protocol (NTP) is being used to update the unit's internal reference <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.22.3 <Object Type> P

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 2

<Definition> Commands the unit to the primary source for adjusting the unit clock: other: the source of the unit time is not defined by this standard. lineSync: the source of the unit time is determined by tracking the (AC) power line frequency rtcSqwr: the source of the unit time a Real Time Clock Square Wave output crystal: the source of the unit time is the internal crystal. This might also be used if the unit time normally uses line frequency but appears to be drifting too much as might happen when on a power generator. gnss: a GNSS device is being used to update the unit's internal reference on a frequent basis (e.g., once per minute)) ntp: the network time protocol (NTP) is being used to update the unit's internal reference <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.22.3

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 1

unitTimeSourceCommanded · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: unitTimeSourceCommanded

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "unitTimeSourceCommanded",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "lineSync",
    "(",
    "2",
    ")",
    ",",
    "rtcSqwr",
    "(",
    "3",
    ")",
    ",",
    "crystal",
    "(",
    "4",
    ")",
    ",",
    "gnss",
    "(",
    "5",
    ")",
    ",",
    "ntp",
    "(",
    "6",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> Commands the unit to the primary source for adjusting the unit clock: other: the source of the unit time is not defined by this standard. lineSync: the source of the unit time is determined by tracking the (AC) power line frequency rtcSqwr: the source of the unit time a Real Time Clock Square Wave output crystal: the source of the unit time is the internal crystal. This might also be used if the unit time normally uses line frequency but appears to be drifting too much as might happen when on a power generator. gnss: a GNSS device is being used to update the unit's internal reference on a frequent basis (e.g., once per minute)) ntp: the network time protocol (NTP) is being used to update the unit's internal reference <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.22.3 <Object Type> P\"",
    "DEFVAL",
    "{",
    "lineSync",
    "}",
    "::=",
    "{",
    "ascClock",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "lineSync",
            2
          ],
          [
            "rtcSqwr",
            3
          ],
          [
            "crystal",
            4
          ],
          [
            "gnss",
            5
          ],
          [
            "ntp",
            6
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> Commands the unit to the primary source for adjusting the unit clock: other: the source of the unit time is not defined by this standard. lineSync: the source of the unit time is determined by tracking the (AC) power line frequency rtcSqwr: the source of the unit time a Real Time Clock Square Wave output crystal: the source of the unit time is the internal crystal. This might also be used if the unit time normally uses line frequency but appears to be drifting too much as might happen when on a power generator. gnss: a GNSS device is being used to update the unit's internal reference on a frequent basis (e.g., once per minute)) ntp: the network time protocol (NTP) is being used to update the unit's internal reference <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.22.3 <Object Type> P"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "lineSync"
    ]
  ]
}
Records for description 2NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 2

unitTimeSourceCommanded · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: unitTimeSourceCommanded

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "unitTimeSourceCommanded",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "lineSync",
    "(",
    "2",
    ")",
    ",",
    "rtcSqwr",
    "(",
    "3",
    ")",
    ",",
    "crystal",
    "(",
    "4",
    ")",
    ",",
    "gnss",
    "(",
    "5",
    ")",
    ",",
    "ntp",
    "(",
    "6",
    ")",
    "}",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> Commands the unit to the primary source for adjusting the unit clock: other: the source of the unit time is not defined by this standard. lineSync: the source of the unit time is determined by tracking the (AC) power line frequency rtcSqwr: the source of the unit time a Real Time Clock Square Wave output crystal: the source of the unit time is the internal crystal. This might also be used if the unit time normally uses line frequency but appears to be drifting too much as might happen when on a power generator. gnss: a GNSS device is being used to update the unit's internal reference on a frequent basis (e.g., once per minute)) ntp: the network time protocol (NTP) is being used to update the unit's internal reference <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.22.3\"",
    "DEFVAL",
    "{",
    "lineSync",
    "}",
    "::=",
    "{",
    "ascClock",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "lineSync",
            2
          ],
          [
            "rtcSqwr",
            3
          ],
          [
            "crystal",
            4
          ],
          [
            "gnss",
            5
          ],
          [
            "ntp",
            6
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> Commands the unit to the primary source for adjusting the unit clock: other: the source of the unit time is not defined by this standard. lineSync: the source of the unit time is determined by tracking the (AC) power line frequency rtcSqwr: the source of the unit time a Real Time Clock Square Wave output crystal: the source of the unit time is the internal crystal. This might also be used if the unit time normally uses line frequency but appears to be drifting too much as might happen when on a power generator. gnss: a GNSS device is being used to update the unit's internal reference on a frequent basis (e.g., once per minute)) ntp: the network time protocol (NTP) is being used to update the unit's internal reference <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.3.22.3"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "lineSync"
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Siblings (7)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.2.1.3.22.1 maxTimeSources00
1.3.6.1.4.1.1206.4.2.1.3.22.2 unitTimeTable13
1.3.6.1.4.1.1206.4.2.1.3.22.4 unitTimeSourceCurrent00
1.3.6.1.4.1.1206.4.2.1.3.22.5 unitTimeSourceStatus00
1.3.6.1.4.1.1206.4.2.1.3.22.6 unitTimeNonSequentialSource00
1.3.6.1.4.1.1206.4.2.1.3.22.7 unitTimeNonSequentialChange00
1.3.6.1.4.1.1206.4.2.1.3.22.8 unitTimeNonSequentialDelta00