An identified reason for failure while
configuring/modifying
ATM Trunking parameters:
localIWFAlreadyConfigured(1) : Local IWF has
already been configured, the
parameters can not be changed or apply again.
localIWFAtmAddressError(2): the ATM Address for
Local IWF is not valid or
this address has been used by someone else.
localIWFIdOutOfRange(3): the Identification of
Local IWF is out of range.
maxNumberRmtIWFOutOfRange(4): the maximum number
of Remote IWF is out of range.
rmtIWFAlreadyConfigured(5): this remote IWF has
already been configured(
with index atmTrunkingRmtIWFIdentifier).
rmtIWFIdOutOfRange: the identifier for the remote
IWF is out of range.
rmtIWFAtmAddressError: the ATM Address for remote
IWF is not valid or
this address has been used by someone else.
vccIdError: the VCC ID for the SigVcc or BrVcc
is 0, or this VCC ID is out of range
or it has been used by someone else.
vccPvcParameterNotAcceptable: the parameters
of PVC side, including slot, port, channel,
vpi, vci, are not acceptable.
vccTrafficParameterNotValid: the VCC traffic
parameters are not acceptable,
including FwPcr01, BwPcr01, FwScr01, BwScr01,
FWMbs01, BwMbs01, BrVccServiceType, BrVccSarType.
vccViVuniNotValid: the configuration of Egress
Vi/VUNI is not acceptable.
vccTrunkParameterNotValid: the parameters for the
Trunk is not supported,
including BrVccMaxAal2ChanId,
BrVccCircuitModeDataSupp,
BrVccFrameModeSupp, BrVccFaxModeSupp,
CASPktXportSupp,
BrVccDTMFPktXportSupp, BrVccMFR1PktXportSupp,
BrVccMFR2PktXportSupp, BrVccPCMEncoding,
BrVccMaxFrameLength,
BrVccIdleChannSuprSupp, BrVccSilenceDetSupp,
BrVccCompressionSpec,AudioProfileId,
SigVccSignaling.
vccTrunkFeatureParameterNotValid: PSAX proprietary
feature parameters not supported
including SigVccInactiveTimer, SigVccRetryTimer,
SigVccRetryLimit,
BrVccInactiveTimer, BrVccRetryTimer,
BrVccRetryLimit, BrVccGr303Supp, BrVccOamStatus.
localIwfNotConfigured(14) :
Local IWF not Configured
localIwfIdNotMatch(15):
specified Local IWF not match
localIwfStatus(16): this operation is not supported
because of the status of Local IWF
rmtIwfNotConfigured(17): Remote IWF Not Configured
rmtIwfModeNotCompatible(18): the Mode of Remote IWF
is not compatiable
rmtIwfStatus(19): this operation is not support
because of the Status of Remote IWF
vccAlreadyConfigured(20):
This VCC has been configured
vccPvcCacReject(21): PVC Configuration rejected by
Cac Reservation Function
requiredFieldMissing(22): mandatory fields missing
outOfResource(23): Atm Trunking Task or System
out of resource for this configuration
rowStatusError(24):Row Status Error with the SNMP
command
generalErrorUnspecified(25): all other unspecified
failure cause.
Parsed from file ac120.my.V07.00.C00.mib.txt
Company: None
Module: ACMIB
An identified reason for failure while
configuring/modifying
ATM Trunking parameters:
localIWFAlreadyConfigured(1) : Local IWF has
already been configured, the
parameters can not be changed or apply again.
localIWFAtmAddressError(2): the ATM Address for
Local IWF is not valid or
this address has been used by someone else.
localIWFIdOutOfRange(3): the Identification of
Local IWF is out of range.
maxNumberRmtIWFOutOfRange(4): the maximum number
of Remote IWF is out of range.
rmtIWFAlreadyConfigured(5): this remote IWF has
already been configured(
with index atmTrunkingRmtIWFIdentifier).
rmtIWFIdOutOfRange: the identifier for the remote
IWF is out of range.
rmtIWFAtmAddressError: the ATM Address for remote
IWF is not valid or
this address has been used by someone else.
vccIdError: the VCC ID for the SigVcc or BrVcc
is 0, or this VCC ID is out of range
or it has been used by someone else.
vccPvcParameterNotAcceptable: the parameters
of PVC side, including slot, port, channel,
vpi, vci, are not acceptable.
vccTrafficParameterNotValid: the VCC traffic
parameters are not acceptable,
including FwPcr01, BwPcr01, FwScr01, BwScr01,
FWMbs01, BwMbs01, BrVccServiceType, BrVccSarType.
vccViVuniNotValid: the configuration of Egress
Vi/VUNI is not acceptable.
vccTrunkParameterNotValid: the parameters for the
Trunk is not supported,
including BrVccMaxAal2ChanId,
BrVccCircuitModeDataSupp,
BrVccFrameModeSupp, BrVccFaxModeSupp,
CASPktXportSupp,
BrVccDTMFPktXportSupp, BrVccMFR1PktXportSupp,
BrVccMFR2PktXportSupp, BrVccPCMEncoding,
BrVccMaxFrameLength,
BrVccIdleChannSuprSupp, BrVccSilenceDetSupp,
BrVccCompressionSpec,AudioProfileId,
SigVccSignaling.
vccTrunkFeatureParameterNotValid: PSAX proprietary
feature parameters not supported
including SigVccInactiveTimer, SigVccRetryTimer,
SigVccRetryLimit,
BrVccInactiveTimer, BrVccRetryTimer,
BrVccRetryLimit, BrVccGr303Supp, BrVccOamStatus.
localIwfNotConfigured(14) :
Local IWF not Configured
localIwfIdNotMatch(15):
specified Local IWF not match
localIwfStatus(16): this operation is not supported
because of the status of Local IWF
rmtIwfNotConfigured(17): Remote IWF Not Configured
rmtIwfModeNotCompatible(18): the Mode of Remote IWF
is not compatiable
rmtIwfStatus(19): this operation is not support
because of the Status of Remote IWF
vccAlreadyConfigured(20):
This VCC has been configured
vccPvcCacReject(21): PVC Configuration rejected by
Cac Reservation Function
requiredFieldMissing(22): mandatory fields missing
outOfResource(23): Atm Trunking Task or System
out of resource for this configuration
rowStatusError(24):Row Status Error with the SNMP
command
generalErrorUnspecified(25): all other unspecified
failure cause.
Parsed from file ACMIB.mib
Module: ACMIB
Vendor: Lucent Technologies
Module: ACMIB
[Automatically extracted from oidview.com]
atmTrunkingConfigFailureCode OBJECT-TYPE SYNTAX INTEGER { localIWFAlreadyConfigured(1), localIWFAtmAddressError(2), localIWFIdOutOfRange(3), maxNumberRmtIWFOutOfRange(4), rmtIWFAlreadyConfigured(5), rmtIWFIdOutOfRange(6), rmtIWFAtmAddressError(7), vccIdError(8), vccPvcParameterNotAcceptable(9), vccTrafficParameterNotValid(10), vccViVuniNotValid(11), vccTrunkParameterNotValid(12), vccTrunkFeatureParameterNotValid(13), localIwfNotConfigured(14), localIwfIdNotMatch(15), localIwfStatus(16), rmtIwfNotConfigured(17), rmtIwfModeNotCompatible(18), rmtIwfStatus(19), vccAlreadyConfigured(20), vccPvcCacReject(21), requiredFieldMissing(22), outOfResource(23), rowStatusError(24), generalErrorUnspecified(25) } MAX-ACCESS read-only STATUS current DESCRIPTION "An identified reason for failure while configuring/modifying ATM Trunking parameters: localIWFAlreadyConfigured(1) : Local IWF has already been configured, the parameters can not be changed or apply again. localIWFAtmAddressError(2): the ATM Address for Local IWF is not valid or this address has been used by someone else. localIWFIdOutOfRange(3): the Identification of Local IWF is out of range. maxNumberRmtIWFOutOfRange(4): the maximum number of Remote IWF is out of range. rmtIWFAlreadyConfigured(5): this remote IWF has already been configured( with index atmTrunkingRmtIWFIdentifier). rmtIWFIdOutOfRange: the identifier for the remote IWF is out of range. rmtIWFAtmAddressError: the ATM Address for remote IWF is not valid or this address has been used by someone else. vccIdError: the VCC ID for the SigVcc or BrVcc is 0, or this VCC ID is out of range or it has been used by someone else. vccPvcParameterNotAcceptable: the parameters of PVC side, including slot, port, channel, vpi, vci, are not acceptable. vccTrafficParameterNotValid: the VCC traffic parameters are not acceptable, including FwPcr01, BwPcr01, FwScr01, BwScr01, FWMbs01, BwMbs01, BrVccServiceType, BrVccSarType. vccViVuniNotValid: the configuration of Egress Vi/VUNI is not acceptable. vccTrunkParameterNotValid: the parameters for the Trunk is not supported, including BrVccMaxAal2ChanId, BrVccCircuitModeDataSupp, BrVccFrameModeSupp, BrVccFaxModeSupp, CASPktXportSupp, BrVccDTMFPktXportSupp, BrVccMFR1PktXportSupp, BrVccMFR2PktXportSupp, BrVccPCMEncoding, BrVccMaxFrameLength, BrVccIdleChannSuprSupp, BrVccSilenceDetSupp, BrVccCompressionSpec,AudioProfileId, SigVccSignaling. vccTrunkFeatureParameterNotValid: PSAX proprietary feature parameters not supported including SigVccInactiveTimer, SigVccRetryTimer, SigVccRetryLimit, BrVccInactiveTimer, BrVccRetryTimer, BrVccRetryLimit, BrVccGr303Supp, BrVccOamStatus. localIwfNotConfigured(14) : Local IWF not Configured localIwfIdNotMatch(15): specified Local IWF not match localIwfStatus(16): this operation is not supported because of the status of Local IWF rmtIwfNotConfigured(17): Remote IWF Not Configured rmtIwfModeNotCompatible(18): the Mode of Remote IWF is not compatiable rmtIwfStatus(19): this operation is not support because of the Status of Remote IWF vccAlreadyConfigured(20): This VCC has been configured vccPvcCacReject(21): PVC Configuration rejected by Cac Reservation Function requiredFieldMissing(22): mandatory fields missing outOfResource(23): Atm Trunking Task or System out of resource for this configuration rowStatusError(24):Row Status Error with the SNMP command generalErrorUnspecified(25): all other unspecified failure cause. " ::= { returnCode 59 }
atmTrunkingConfigFailureCode OBJECT-TYPE SYNTAX INTEGER { localIWFAlreadyConfigured(1), localIWFAtmAddressError(2), localIWFIdOutOfRange(3), maxNumberRmtIWFOutOfRange(4), rmtIWFAlreadyConfigured(5), rmtIWFIdOutOfRange(6), rmtIWFAtmAddressError(7), vccIdError(8), vccPvcParameterNotAcceptable(9), vccTrafficParameterNotValid(10), vccViVuniNotValid(11), vccTrunkParameterNotValid(12), vccTrunkFeatureParameterNotValid(13), localIwfNotConfigured(14), localIwfIdNotMatch(15), localIwfStatus(16), rmtIwfNotConfigured(17), rmtIwfModeNotCompatible(18), rmtIwfStatus(19), vccAlreadyConfigured(20), vccPvcCacReject(21), requiredFieldMissing(22), outOfResource(23), rowStatusError(24), generalErrorUnspecified(25) } MAX-ACCESS read-only STATUS current DESCRIPTION "An identified reason for failure while configuring/modifying ATM Trunking parameters: localIWFAlreadyConfigured(1) : Local IWF has already been configured, the parameters can not be changed or apply again. localIWFAtmAddressError(2): the ATM Address for Local IWF is not valid or this address has been used by someone else. localIWFIdOutOfRange(3): the Identification of Local IWF is out of range. maxNumberRmtIWFOutOfRange(4): the maximum number of Remote IWF is out of range. rmtIWFAlreadyConfigured(5): this remote IWF has already been configured( with index atmTrunkingRmtIWFIdentifier). rmtIWFIdOutOfRange: the identifier for the remote IWF is out of range. rmtIWFAtmAddressError: the ATM Address for remote IWF is not valid or this address has been used by someone else. vccIdError: the VCC ID for the SigVcc or BrVcc is 0, or this VCC ID is out of range or it has been used by someone else. vccPvcParameterNotAcceptable: the parameters of PVC side, including slot, port, channel, vpi, vci, are not acceptable. vccTrafficParameterNotValid: the VCC traffic parameters are not acceptable, including FwPcr01, BwPcr01, FwScr01, BwScr01, FWMbs01, BwMbs01, BrVccServiceType, BrVccSarType. vccViVuniNotValid: the configuration of Egress Vi/VUNI is not acceptable. vccTrunkParameterNotValid: the parameters for the Trunk is not supported, including BrVccMaxAal2ChanId, BrVccCircuitModeDataSupp, BrVccFrameModeSupp, BrVccFaxModeSupp, CASPktXportSupp, BrVccDTMFPktXportSupp, BrVccMFR1PktXportSupp, BrVccMFR2PktXportSupp, BrVccPCMEncoding, BrVccMaxFrameLength, BrVccIdleChannSuprSupp, BrVccSilenceDetSupp, BrVccCompressionSpec,AudioProfileId, SigVccSignaling. vccTrunkFeatureParameterNotValid: PSAX proprietary feature parameters not supported including SigVccInactiveTimer, SigVccRetryTimer, SigVccRetryLimit, BrVccInactiveTimer, BrVccRetryTimer, BrVccRetryLimit, BrVccGr303Supp, BrVccOamStatus. localIwfNotConfigured(14) : Local IWF not Configured localIwfIdNotMatch(15): specified Local IWF not match localIwfStatus(16): this operation is not supported because of the status of Local IWF rmtIwfNotConfigured(17): Remote IWF Not Configured rmtIwfModeNotCompatible(18): the Mode of Remote IWF is not compatiable rmtIwfStatus(19): this operation is not support because of the Status of Remote IWF vccAlreadyConfigured(20): This VCC has been configured vccPvcCacReject(21): PVC Configuration rejected by Cac Reservation Function requiredFieldMissing(22): mandatory fields missing outOfResource(23): Atm Trunking Task or System out of resource for this configuration rowStatusError(24):Row Status Error with the SNMP command generalErrorUnspecified(25): all other unspecified failure cause. " ::= { returnCode 59 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1751.2.18.15.59.0 | atmTrunkingConfigFailureCode | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1751.2.18.15.1 | pvcFailureReasonCode | 1 | 1 | An identified reason why an ATM PVC connection request failed. |
1.3.6.1.4.1.1751.2.18.15.2 | interfaceIndex | 1 | 1 | Interface index used for identifcation in traps. Number value is interpreted as an interface of the form, SSPPCCC, where SS is th… |
1.3.6.1.4.1.1751.2.18.15.3 | interfaceType | 1 | 1 | Interface type used for identification in traps. A specific interface is associated with each number. |
1.3.6.1.4.1.1751.2.18.15.4 | interfaceFailureReasonCode | 1 | 1 | Identification of cause for failure in changing the status of an interface. interfaceInService: Most, if not all, modifications r… |
1.3.6.1.4.1.1751.2.18.15.5 | powerSupplyReasonCode | 1 | 1 | Identification for change in status of a power supply. |
1.3.6.1.4.1.1751.2.18.15.6 | portId | 1 | 1 | Port ID used for identification in traps. Number value is interpreted as a port of the form, SSPP, where SS is the card slot and… |
1.3.6.1.4.1.1751.2.18.15.7 | lineStatus | 1 | 1 | Bit map of the status of a line connected to a port. |
1.3.6.1.4.1.1751.2.18.15.8 | firmwareDownloadReasonCode | 1 | 1 | The suspected reasons of why a firmware download would fail. |
1.3.6.1.4.1.1751.2.18.15.9 | remoteRebootReasonCode | 1 | 1 | The result of a remote reboot request. |
1.3.6.1.4.1.1751.2.18.15.10 | saveConfigurationReasonCode | 1 | 1 | The result of a save configuration request. |
1.3.6.1.4.1.1751.2.18.15.11 | versionConfigurationReasonCode | 1 | 1 | Indicated status and results of version changing |
1.3.6.1.4.1.1751.2.18.15.12 | percentComplete | 1 | 1 | Used for trap fileTransferStatusNotify and value equals the percent of the upgrade, downgrade, or ftp download completed. |
1.3.6.1.4.1.1751.2.18.15.13 | ipTypeReasonCode | 1 | 1 | Indicator of which ip address had the problem. |
1.3.6.1.4.1.1751.2.18.15.14 | timingReasonCode | 1 | 1 | Indicator of type of relationship violated. |
1.3.6.1.4.1.1751.2.18.15.15 | alarmCardReasonCode | 1 | 1 | Configuration status of the alarm inputs and outputs. |
1.3.6.1.4.1.1751.2.18.15.16 | removeConfigFiles | 1 | 1 | Used to indicate the status of a remove configuration files request. |
1.3.6.1.4.1.1751.2.18.15.17 | spvcConfigFailureCode | 1 | 1 | Identification of cause for failure while configuring/modifying SPVC parameters. noSpvcConfigured : There endpoint has not been co… |
1.3.6.1.4.1.1751.2.18.15.18 | imaGrpChannelStatus | 1 | 1 | The return value for the imaGrpChannelFailNotify trap. startupFe cfgAbort configuartion parameters cfgAbortFe configuration paramete… |
1.3.6.1.4.1.1751.2.18.15.19 | atmImaIntfStatus | 1 | 1 | The return value for the atmImaIntfFailNotify trap. lif (Loss of IMA Frame) lods (Link Out of Delay Synchronization) txMisConnect the… |
1.3.6.1.4.1.1751.2.18.15.20 | deviceId | 1 | 1 | device ID is used as the number of external devices. Each device can be an external input device or control output device. |
1.3.6.1.4.1.1751.2.18.15.21 | oamTestFailureReasonCode | 1 | 1 | An identified reason why an OAM Loopback Test request has failed. |
1.3.6.1.4.1.1751.2.18.15.22 | pnniCode | 1 | 1 | An identified reason for Miscellaneous Reasons in PNNI Configuration. |
1.3.6.1.4.1.1751.2.18.15.23 | swtchNodeIndx | 1 | 1 | Switch Node Index for PNNI. |
1.3.6.1.4.1.1751.2.18.15.24 | oc3APSPairPortIndex | 1 | 1 | APS Pair Port index - SSPP |
1.3.6.1.4.1.1751.2.18.15.25 | oc3APSReasonCode | 1 | 1 | Enumerated values of the outcome of previous apsPair UserCommand or alarms on the line |
1.3.6.1.4.1.1751.2.18.15.26 | oc3APSK1K2Rx | 1 | 1 | Rx K1/K2 followed by hex value of K1, K2 |
1.3.6.1.4.1.1751.2.18.15.27 | oc3APSK1K2Tx | 1 | 1 | Tx K1/K2 followed by hex value of K1, K2 |
1.3.6.1.4.1.1751.2.18.15.28 | oc3APSSelectorState | 1 | 1 | W: active/standby P: standby/active |
1.3.6.1.4.1.1751.2.18.15.29 | oc3APSWorkingLineSignalStatus | 1 | 1 | Line Status of the working port sent in a trap |
1.3.6.1.4.1.1751.2.18.15.30 | oc3APSProtectionLineSignalStatus | 1 | 1 | Line Status of the protection port sent in a trap. |
1.3.6.1.4.1.1751.2.18.15.31 | arpStatus | 1 | 1 | Success: Arp Data is Available. Failure: Reply from RS Card timed-out. |
1.3.6.1.4.1.1751.2.18.15.32 | routingStatus | 1 | 1 | Success: Routing Data is Available. Failure: Reply from RS Card timed-out. |
1.3.6.1.4.1.1751.2.18.15.33 | vpnTrapStatus | 1 | 1 | Return codes for route server VPN level operations. |
1.3.6.1.4.1.1751.2.18.15.34 | ipIntfStatus | 1 | 1 | Return codes for route server IP interface operations. |
1.3.6.1.4.1.1751.2.18.15.35 | subChanStatus | 1 | 1 | Return codes for route server sub channel connections operations. |
1.3.6.1.4.1.1751.2.18.15.36 | routeSrvStatus | 1 | 1 | Return codes for basic route server task operations not related to any specific VPN or IP/Connection operation. |
1.3.6.1.4.1.1751.2.18.15.37 | apsFailureReasonCode | 1 | 1 | aps failure reason |
1.3.6.1.4.1.1751.2.18.15.38 | statRtStatus | 1 | 1 | Return codes for route server static route condititions. |
1.3.6.1.4.1.1751.2.18.15.39 | portFailureReasonCode | 1 | 1 | Identification of cause for failure in changing the parameters of a port |
1.3.6.1.4.1.1751.2.18.15.40 | dlciNumber | 1 | 1 | The number of the dlci being used. |
1.3.6.1.4.1.1751.2.18.15.41 | ipAddrNumber | 1 | 1 | The IP address of the host/network to be echoed |
1.3.6.1.4.1.1751.2.18.15.42 | pingStatusReasonCode | 1 | 1 | The response value - Alive/Not Alive |
1.3.6.1.4.1.1751.2.18.15.43 | primarySoftwareVersion | 1 | 1 | Software version running on primary cpu. |
1.3.6.1.4.1.1751.2.18.15.44 | backupSoftwareVersion | 1 | 1 | Software version running on backup cpu. |
1.3.6.1.4.1.1751.2.18.15.45 | oamActDeactResultCode | 1 | 1 | Various result codes for the operator's command for OAM Activation-Deactivation. |
1.3.6.1.4.1.1751.2.18.15.46 | tasCmprsAnnceReasonCode | 1 | 1 | The result of a compress announcement request. |
1.3.6.1.4.1.1751.2.18.15.47 | tasTstLineReasonCode | 1 | 1 | The result of a test line request. |
1.3.6.1.4.1.1751.2.18.15.48 | gr303PPSReasonCode | 1 | 1 | gr303 PPS reason code |
1.3.6.1.4.1.1751.2.18.15.49 | gr303PPSSource | 1 | 1 | gr303 PPS source |
1.3.6.1.4.1.1751.2.18.15.50 | tasMemReasonCode | 1 | 1 | The result of a memory init request. |
1.3.6.1.4.1.1751.2.18.15.51 | tasTrapTstId | 1 | 1 | Announcement ID for trap. |
1.3.6.1.4.1.1751.2.18.15.52 | tasTrapAnnceId | 1 | 1 | test id for trap. |
1.3.6.1.4.1.1751.2.18.15.53 | atmVpi | 1 | 1 | Vpi is used in identification of Traps |
1.3.6.1.4.1.1751.2.18.15.54 | atmVci | 1 | 1 | Vci is used in identification of Traps |
1.3.6.1.4.1.1751.2.18.15.55 | iptResultCode | 1 | 1 | Various result codes for the operator's command forsetting/deleting interface protection group. |
1.3.6.1.4.1.1751.2.18.15.56 | pgtResultCode | 1 | 1 | Various result codes for the operator's command for interface protection . |
1.3.6.1.4.1.1751.2.18.15.57 | tasmControlBlockAllocFailReasonCode | 1 | 1 | The result of a tasm control block memory allocation request. |
1.3.6.1.4.1.1751.2.18.15.58 | tasmCacheMemAllocFailReasonCode | 1 | 1 | The result of a tasm control block memory allocation request. |
1.3.6.1.4.1.1751.2.18.15.60 | sapphireIntfAddressFailReasonCode | 1 | 1 | The result of assigning the Sapphire Interface address when PSAX is Sapphire client. address-ok(1), Address assignment suc… |
1.3.6.1.4.1.1751.2.18.15.61 | chassisOverTempAlarmReasonCode | 1 | 1 | Indicator of presence of chassis over temperature alarm. |