Packing of serial data into T1 DS0's. Bit-7-stuff
supports DTE rates of nX56Kb/s (from 56K to 1344K) and
provides sufficient ones-density on any circuit.
Clear-channel allows DTE rates of nX64Kb/s (from 64K
to 1.536M) and may require an additional means
of density enforcement (eg, B8ZS). This read-only value
is the value which was most recently set through CfgDteConnDensity;
in the event of a connection failure, this field should be
examined along with CfgDteLineRate and CfgDteStartDso to
determine the parameter mismatch that caused the connection
failure.
Parsed from file MFRAP.MIB.txt
Company: None
Module: MFRAP-MIB
Packing of serial data into T1 DS0's. Bit-7-stuff
supports DTE rates of nX56Kb/s (from 56K to 1344K) and
provides sufficient ones-density on any circuit.
Clear-channel allows DTE rates of nX64Kb/s (from 64K
to 1.536M) and may require an additional means
of density enforcement (eg, B8ZS). This read-only value
is the value which was most recently set through CfgDteConnDensity;
in the event of a connection failure, this field should be
examined along with CfgDteLineRate and CfgDteStartDso to
determine the parameter mismatch that caused the connection
failure.
Parsed from file MFRAP-MIB.mib
Module: MFRAP-MIB
Vendor: Sync Research, Inc.
Module: MFRAP-MIB
[Automatically extracted from oidview.com]
mfrapCfgDteChannelDensity OBJECT-TYPE SYNTAX INTEGER { bit-7-stuff (56), clear-channel (64) } ACCESS read-only STATUS mandatory DESCRIPTION "Packing of serial data into T1 DS0's. Bit-7-stuff supports DTE rates of nX56Kb/s (from 56K to 1344K) and provides sufficient ones-density on any circuit. Clear-channel allows DTE rates of nX64Kb/s (from 64K to 1.536M) and may require an additional means of density enforcement (eg, B8ZS). This read-only value is the value which was most recently set through CfgDteConnDensity; in the event of a connection failure, this field should be examined along with CfgDteLineRate and CfgDteStartDso to determine the parameter mismatch that caused the connection failure." ::= { mfrapCfgDteTable 6 }
mfrapCfgDteChannelDensity OBJECT-TYPE SYNTAX INTEGER { bit-7-stuff (56), clear-channel (64) } ACCESS read-only STATUS mandatory DESCRIPTION "Packing of serial data into T1 DS0's. Bit-7-stuff supports DTE rates of nX56Kb/s (from 56K to 1344K) and provides sufficient ones-density on any circuit. Clear-channel allows DTE rates of nX64Kb/s (from 64K to 1.536M) and may require an additional means of density enforcement (eg, B8ZS). This read-only value is the value which was most recently set through CfgDteConnDensity; in the event of a connection failure, this field should be examined along with CfgDteLineRate and CfgDteStartDso to determine the parameter mismatch that caused the connection failure." ::= { mfrapCfgDteTable 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.485.8.2.4.6.0 | mfrapCfgDteChannelDensity | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.485.8.2.4.1 | mfrapCfgDteIntfType | 1 | 1 | mfrapCfgDteIntftype |
1.3.6.1.4.1.485.8.2.4.2 | mfrapCfgDteDataMode | 1 | 1 | Inverts the DTE data for transfer across the WAN. Can make some applications, particularly HDLC-based protocols, meet density req… |
1.3.6.1.4.1.485.8.2.4.3 | mfrapCfgDteClockMode | 1 | 1 | This selection controls how the unit internally latches the transmit data from the DTE. Normal will sample data with the rising e… |
1.3.6.1.4.1.485.8.2.4.4 | mfrapCfgDteTiming | 1 | 1 | Serial DTE Transmit Timing mode. Loop-1 (1) uses the clock returned from the DTE (TT/TCE) to sample tx data, Loop-2 (2) uses the … |
1.3.6.1.4.1.485.8.2.4.5 | mfrapCfgDteLineRate | 1 | 1 | Serial DTE Data Rate in bits per second. Valid rates depend upon channel density selection: nX56K for bit-7-stuffing, and nX64K f… |
1.3.6.1.4.1.485.8.2.4.7 | mfrapCfgDteStartDs0 | 1 | 1 | T1 WAN includes 24 DS0's available for user data. Each DS0 carries either 56Kbit/sec (bit-7-stuffing) or 64KBit/sec (clear-channe… |
1.3.6.1.4.1.485.8.2.4.8 | mfrapCfgDteConnStatus | 1 | 1 | The current status of the WAN to DTE mappings. (1) connections valid and DS0s allocated to DTE data. (4) no connections configure… |
1.3.6.1.4.1.485.8.2.4.9 | mfrapCfgDteConnStartDs0 | 1 | 1 | T1 WAN includes 24 DS0's available for user data. Each DS0 carries either 56Kbit/sec (bit-7-stuffing) or 64KBit/sec (clear-channe… |
1.3.6.1.4.1.485.8.2.4.10 | mfrapCfgDteConnRate | 1 | 1 | Serial DTE Data Rate in bits per second. Valid rates depend upon channel density selection: nX56K for bit-7-stuffing, and nX64K f… |
1.3.6.1.4.1.485.8.2.4.11 | mfrapCfgDteConnDensity | 1 | 1 | Packing of serial data into T1 DS0's. Bit-7-stuff supports DTE rates of nX56Kb/s (from 56K to 1344K) and provides sufficient ones… |
1.3.6.1.4.1.485.8.2.4.12 | mfrapCfgDteConnDs0Required | 1 | 1 | The number of DS0s required by the node's DTE port. This is based upon the DTE data rate and channel density selections. |
1.3.6.1.4.1.485.8.2.4.13 | mfrapCfgDteConnAutoStatus | 1 | 1 | There's a tight correlation among DTE data rate, starting DS0, and channel density. This read-only parameter reports the status o… |
1.3.6.1.4.1.485.8.2.4.14 | mfrapCfgDteConnAutoUpdate | 1 | 1 | Updates the connection-critical parameters: line rate, channel density and starting ds0; drops the currect connection; and initia… |
1.3.6.1.4.1.485.8.2.4.15 | mfrapCfgDteRts | 1 | 1 | Selects whether the RTS signal is external-from-dte (2) or internal-held-active (1). |
1.3.6.1.4.1.485.8.2.4.16 | mfrapCfgDteDtr | 1 | 1 | Selects whether the DTR signal is external-from-dte (2) or internal-held-active (1). |
1.3.6.1.4.1.485.8.2.4.18 | mfrapCfgDteDcdOutput | 1 | 1 | Specifies the behavior of this control signal generated by the M-FRAP towards the DTE. inactive-always (1) - signal is permanentl… |
1.3.6.1.4.1.485.8.2.4.19 | mfrapCfgDteDsrOutput | 1 | 1 | Specifies the behavior of this control signal generated by the M-FRAP towards the DTE. inactive-always (1) - signal is permanentl… |
1.3.6.1.4.1.485.8.2.4.20 | mfrapCfgDteCtsOutput | 1 | 1 | Specifies the behavior of this control signal generated by the M-FRAP towards the DTE. inactive-always (1) - signal is permanentl… |