OID reference

fan-af-dx-sp

1.3.6.1.4.1.9839.2.1.3.97

Description

Fan air flow setpoint for DX unit (cfm)

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.9839.2.1.3 (integerObjects)
Node code
97
Node names
  • fan-af-dx-sp
  • config_out1
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.9839.2.1.3.97
URN notation
urn:oid:1.3.6.1.4.1.9839.2.1.3.97
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 9839 2 1 3 97}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) integerObjects(3) fan-af-dx-sp(97)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) integerObjects(3) fan-af-dx-sp(97)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) integerObjects(3) fan-af-dx-sp(97)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) integerObjects(3) fan-af-dx-sp(97)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uncdz-MIB(1) integerObjects(3) fan-af-dx-sp(97)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mcellaMIB(1) integerObjects(3) fan-af-dx-sp(97)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mastercaseMIB(1) integerObjects(3) fan-af-dx-sp(97)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mastercellasplitMIB(1) integerObjects(3) fan-af-dx-sp(97)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) wlprobeMIB(1) integerObjects(3) fan-af-dx-sp(97)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) insgrdMIB(1) integerObjects(3) fan-af-dx-sp(97)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ariaMIB(1) integerObjects(3) fan-af-dx-sp(97)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) pluginMIB(1) integerObjects(3) fan-af-dx-sp(97)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mioMIB(1) integerObjects(3) fan-af-dx-sp(97)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) powersplitMIB(1) integerObjects(3) fan-af-dx-sp(97)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) fcpMIB(1) integerObjects(3) fan-af-dx-sp(97)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uchillerMIB(1) integerObjects(3) fan-af-dx-sp(97)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/9839/2/1/3/97
  • /ISO/Identified-Organization/6/1/4/1/9839/2/1/3/97
  • /ISO/3/6/1/4/1/9839/2/1/3/97
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/fan-af-dx-sp
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/config_out1
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/integerObjects/fan-af-dx-sp
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/integerObjects/config_out1
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/dap4-alMIB/integerObjects/fan-af-dx-sp
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/dap4-alMIB/integerObjects/config_out1
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/uacMIB/integerObjects/fan-af-dx-sp
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/uacMIB/integerObjects/config_out1
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/uncdz-MIB/integerObjects/fan-af-dx-sp
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/uncdz-MIB/integerObjects/config_out1
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/mcellaMIB/integerObjects/fan-af-dx-sp
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/mcellaMIB/integerObjects/config_out1
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/cfp_ncpMIB/integerObjects/fan-af-dx-sp
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/cfp_ncpMIB/integerObjects/config_out1
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/mastercaseMIB/integerObjects/fan-af-dx-sp
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/mastercaseMIB/integerObjects/config_out1
  • Additional combinations skipped.

SNMP properties

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Default value
0

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Allowed ranges
-32767–32767

Variant 2 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Default value
0
Allowed ranges
0–32000

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.9839.2.1.3.97.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

config_out1 · current

config_out1 OBJECT-TYPE
                    SYNTAX Integer32 (-32767..32767)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Type of device connected to output 1"
                    ::= { integerObjects 97 }

fan-af-dx-sp · current

fan-af-dx-sp OBJECT-TYPE
                    SYNTAX Integer32 (0..32000)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Fan air flow setpoint for DX unit (cfm)"
                    DEFVAL { 0 }
                    ::= { integerObjects 97 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Fan air flow setpoint for DX unit (cfm)
Original text from OID Repository
fan-af-dx-sp OBJECT-TYPE
SYNTAX Integer32 (0..32000)
UNITS "N/A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Fan air flow setpoint for DX unit (cfm)"
DEFVAL { 0 }
Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

OID Repository

View at oid-base.com

Description 2

Type of device connected to output 1

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 2Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 2

config_out1 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: config_out1

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "config_out1",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "32767",
    ".",
    ".",
    "32767",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Type of device connected to output 1\"",
    "::=",
    "{",
    "integerObjects",
    "97",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -32767,
            32767
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Type of device connected to output 1"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 1

fan-af-dx-sp · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)2 sources

Status in source: current.

Names: fan-af-dx-sp

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "fan-af-dx-sp",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "32000",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Fan air flow setpoint for DX unit (cfm)\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "97",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            32000
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Fan air flow setpoint for DX unit (cfm)"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.9839)

Fiorindo Sebastiano

Siblings (121)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.9839.2.1.3.51 assist-sel, time-Min-Off-Freecooling-Chiller-timing, min_volt_f2, stn, defrost_t4_mm, versione_sw_hg, f7, sgl_ore_comp1, defrost_t6_dd, swrel00 0= no comp assist, 1=one comp assist, 2= two comp assist, 3... 4...
1.3.6.1.4.1.9839.2.1.3.52 wtrvlv-sel, time-Min-Different-Freecooling-Chiller-timing, max_volt_f3, durata_pulizia, rit_acc_comp, p5, sgl_ore_comp2, defrost_t6_hh, lt_al_thrsh_al00 Water valve type 0=none, 1=chill, 2=Engy, 3=Aux chill, 4=Disc Reg
1.3.6.1.4.1.9839.2.1.3.53 wtrvlv-volts-sel, time-Min-Same-Freecooling-Chiller-timing, triac_durat_f4, par_ora1, th, rit_spegn_comp, p9, defrost_t6_mm, sg_ore_comp, di1_config_a400 Water valve voltage 0= 0-10, 1=2-10, 2=7-10, 3=6-9, 4=4-7
1.3.6.1.4.1.9839.2.1.3.54 hum-volts, integral-Time-Freeccoling-Valve-PID, min_out_val_f7, par_ora2, tdow, p10, in_rampa_p3v, tm, hour_comp1, di2_config_a500 % of 10volts of analog output #2
1.3.6.1.4.1.9839.2.1.3.55 dehum-hours-h, derivative-Time-Freeccoling-Valve-PID, max_out_val_f8, manual_position, p11, fin_rampa_p3v, th, hour_l_comp1, comp_off_ext_a600 Dehumidifier Runtime - High
1.3.6.1.4.1.9839.2.1.3.56 dehum-hours-l, output-Address-Valve-Freecooling, min_on_time_c1, posizione_valvola_perc, tempo_acc_pompa, p6, in_rampa_n3v, td, hour_comp2, tm_delay_id_a700 Dehumidifier Runtime - Low
1.3.6.1.4.1.9839.2.1.3.57 delay-Freecooling-Thermal-Exclusion, min_off_time_c2, modello_valvola, h7, fin_rampa_n3v, hour_l_comp2, temp_al_del_ad00
1.3.6.1.4.1.9839.2.1.3.58 autoflush-dly, n-of-alarm-External-Dry-Cooler, t_betw_2_on_c3, ti_int, tempo_run, hour_comp3, cnf_di_virt_a800 Time between drain cycles 0=12hr, 1=24hr, 2=48hr, 3=96hr, 4=None
1.3.6.1.4.1.9839.2.1.3.59 y4-out, delay-Alarm-Static-Pressure, t_comp_2_on_c4, ti_low, h13, rit_syson, hour_l_comp3, en_lan_di2_a900 Value sent to optional analog output#1
1.3.6.1.4.1.9839.2.1.3.60 y5-out, n-of-Alarm-Static-Pressure, t_comp_2_off_c5, tipogas, h6, hour_comp4, en_mt_al_slv_ra00 Value sent to optional analog output#2
1.3.6.1.4.1.9839.2.1.3.61 air-flow, delay-Warning-Static-Pressure, t_comp_fan_c7, delay_pressure_probe_alarm, h10, vr1cen, hour_l_comp4, fans_mng_f000 Current Fan Airflow - Based on calculated Pressure Diff formula
1.3.6.1.4.1.9839.2.1.3.62 opt-snsr1-name, n-of-Warning-Static-Pressure, off_fan_d_fd, tipo_sonda_eva, vr2cen, hour_comp500 Name of the sensor
1.3.6.1.4.1.9839.2.1.3.63 opt-sns-1-ain-type, n-of-Alarm-Differential-Pressure, on_dalay_hg, ore_mac, hour_l_comp5, fan_0_cmp_0_f200 Analog Sensor 1 Type {0=NTC 1=PT1000 2=0-1VDC 3=0-10VDC 4=4-20mA 5=ON/OFF 6=0-5VDC 7=NTC HT 8=-50T90 9=10T170}
1.3.6.1.4.1.9839.2.1.3.64 opt-snsr2-name, priming-Time-Hydraulic-Pressure, en_rotat_c6, cmp_start_valve_position, hour_comp6, fan_0_on_def_f300 Name of the sensor
1.3.6.1.4.1.9839.2.1.3.65 opt-sns-2-ain-type, delay-priming-Time-Hydraulic-Pressure, d_flow_s_p1, dd_1, ore_comp1, hour_l_comp6, fan_rele_f400 Analog Sensor 2 Type {0=NTC 1=PT1000 2=0-1VDC 3=0-10VDC 4=4-20mA 5=ON/OFF 6=0-5VDC 7=NTC HT 8=-50T90 9=10T170}
1.3.6.1.4.1.9839.2.1.3.66 opt-snsr3-name, output-Address-Alarm-Static-Pressure, d_flow_run_p2, hh_1, ore_comp2, h_hour_fan1, tm_off_drip_fd00 Name of the sensor
1.3.6.1.4.1.9839.2.1.3.67 opt-sns-3-ain-type, n-of-Alarm-Flow-Rate, lp_delay_p3, mm_1, h1, x_h_main_fan, l_hour_fan100 Analog Sensor 3 Type {0=NTC 1=PT1000 2=0-1VDC 3=0-10VDC 4=4-20mA 5=ON/OFF 6=0-5VDC 7=NTC HT 8=-50T90 9=10T170}
1.3.6.1.4.1.9839.2.1.3.68 opt-snsr4-name, priming-Time-Flow-Rate, al_prb_delay_pa, dd_2, h2, x_h_valve_comp1, h_hour_fan2, relay4_mode_h100 Name of the sensor
1.3.6.1.4.1.9839.2.1.3.69 opt-sns-4-ain-type, delay-priming-Time-Flow-Rate, al_gen_delay_pc, hh_2, x_h_valve_comp2, l_hour_fan2, en_dis_keyb_h200 Analog Sensor 4 Type {0=NTC 1=PT1000 2=0-1VDC 3=0-10VDC 4=4-20mA 5=ON/OFF 6=0-5VDC 7=NTC HT 8=-50T90 9=10T170}
1.3.6.1.4.1.9839.2.1.3.70 cw-fan-speed-bms, bms-address-IDENT, t_slot_cfg_rt, mm_2, f5, h_hour_fan3, remote_control00 CW Fan speed (%) sent via BMS
1.3.6.1.4.1.9839.2.1.3.71 dx-fan-speed-bms, fan_time_fe, dd_3, d1, l_hour_fan300 DX Fan speed (%) sent via BMS
1.3.6.1.4.1.9839.2.1.3.72 fan-speed-max, abilitazione_allarme_fumo, hh_3, d2, h_hour_fan400 Maximum Fan speed (% of output) modulation.
1.3.6.1.4.1.9839.2.1.3.73 fan-speed-min, abilitazione_allarme_cf, mm_3, d5, l_hour_fan400 Minimum Fan speed (% of output) modulation from pressure.
1.3.6.1.4.1.9839.2.1.3.74 fan-pr-sp, abilitazione_allarme_ht, dd_4, d6, sg_ore_fan, lan_address_sa00 Fan pressure setpoint (0.01 inches of water)
1.3.6.1.4.1.9839.2.1.3.75 fan-pr-band, hh_4, d7, version, lan_lenght_sn00 Fan pressure band (0.01 inches of water)
1.3.6.1.4.1.9839.2.1.3.76 fan-af-max, mm_4, d8, h_hour_fan5, hh_def_sched100 Maximum air flow limit of setpoint from BMS or valve modulation.
1.3.6.1.4.1.9839.2.1.3.77 fan-af-min, dd_5, d9, l_hour_fan5, mm_def_sched100 Minimum air flow limit of setpoint from BMS or valve modulation.
1.3.6.1.4.1.9839.2.1.3.78 fan-kfactor, hh_5, d10, time_on_black_out, hh_def_sched200 Fan K Factor
1.3.6.1.4.1.9839.2.1.3.79 num-fans, mm_5, d12, config_in1, mm_def_sched200 Number of fans installed in this unit
1.3.6.1.4.1.9839.2.1.3.80 dd_6, d13, config_in2, hh_def_sched300
1.3.6.1.4.1.9839.2.1.3.81 ht2-hours-h, hh_6, config_in3, mm_def_sched300 Heater 2 Runtime - high
1.3.6.1.4.1.9839.2.1.3.82 ht2-hours-l, mm_6, config_in4, hh_def_sched400 Heater 2 Runtime - low
1.3.6.1.4.1.9839.2.1.3.83 ht3-hours-h, dd_7, r27, config_in5, mm_def_sched400 Heater 3 Runtime - high
1.3.6.1.4.1.9839.2.1.3.84 ht3-hours-l, hh_7, l4, config_in6, hh_def_sched500 Heater 3 Runtime - low
1.3.6.1.4.1.9839.2.1.3.85 engy-hours-h, mm_7, h16, config_in7, mm_def_sched500 Energy Saver Runtime - This optional point applies to energy saver units only -high
1.3.6.1.4.1.9839.2.1.3.86 engy-hours-l, dd_8, p12, config_in8, hh_def_sched600 Energy Saver Runtime - This optional point applies to energy saver units only - low
1.3.6.1.4.1.9839.2.1.3.87 cw-hours-h, hh_8, l1, config_in9, mm_def_sched600 Chilled Water Runtime - This applies to chilled water units only - high
1.3.6.1.4.1.9839.2.1.3.88 cw-hours-l, mm_8, l2, config_in10, hh_def_sched700 Chilled Water Runtime - This applies to chilled water units only - low
1.3.6.1.4.1.9839.2.1.3.89 c3-hours-h, l3, config_in11, mm_def_sched700 Compressor 3 Runtime - This applies when unit has four stages tandem compressors - high
1.3.6.1.4.1.9839.2.1.3.90 c3-hours-l, l5, config_in12, hh_def_sched800 Compressor 3 Runtime - This applies when unit has four stages tandem compressors - low
1.3.6.1.4.1.9839.2.1.3.91 c4-hours-l, r14, config_in13, mm_def_sched800 Compressor 4 Runtime - This applies when unit has four stages tandem compressors. - high
1.3.6.1.4.1.9839.2.1.3.92 c4-hours-h, config_in14, hh_clock00 Compressor 4 Runtime - This applies when unit has four stages tandem compressors. - low
1.3.6.1.4.1.9839.2.1.3.93 cond-hours-h, config_in15, mm_clock00 Condenser Runtime - high
1.3.6.1.4.1.9839.2.1.3.94 cond-hours-l, config_in16, hh_vis00 Condenser Runtime - low
1.3.6.1.4.1.9839.2.1.3.95 dx-fan-speed, config_in17, mm_vis00 Fan speed (% of output) when compressor cooling.
1.3.6.1.4.1.9839.2.1.3.96 cw-fan-speed, config_in1800 Fan speed (% of output) when cold water cooling.
1.3.6.1.4.1.9839.2.1.3.98 fan-af-cw-sp, config_out200 Fan air flow setpoint for CW unit (cfm)
1.3.6.1.4.1.9839.2.1.3.99 zm-airflow-sp, chiller-name0, config_out300 Zone Airflow Setpoint kcfm
1.3.6.1.4.1.9839.2.1.3.100 chiller-name1, config_out400
1.3.6.1.4.1.9839.2.1.3.101 config_out500