OID reference

phaseDynamicMaxStep

1.3.6.1.4.1.1206.4.2.1.1.2.1.19

Description

<Definition> This object shall determine the automatic adjustment to the running max in tenth seconds (0-25.5) When a phase maxes out twice in a row, and on each successive max out thereafter, one dynamic max step value shall be added to the running max until such addition would mean the running max was greater than t…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.2.1.1.2.1 (phaseEntry)
Node code
19
Node name
phaseDynamicMaxStep
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.2.1.1.2.1.19
URN notation
urn:oid:1.3.6.1.4.1.1206.4.2.1.1.2.1.19
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 2 1 1 2 1 19}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) phase(1) phaseTable(2) phaseEntry(1) phaseDynamicMaxStep(19)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) phase(1) phaseTable(2) phaseEntry(1) phaseDynamicMaxStep(19)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) phase(1) phaseTable(2) phaseEntry(1) phaseDynamicMaxStep(19)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) phase(1) phaseTable(2) phaseEntry(1) phaseDynamicMaxStep(19)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) phase(1) phaseTable(2) phaseEntry(1) phaseDynamicMaxStep(19)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) phase(1) phaseTable(2) phaseEntry(1) phaseDynamicMaxStep(19)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) phase(1) phaseTable(2) phaseEntry(1) phaseDynamicMaxStep(19)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) phase(1) phaseTable(2) phaseEntry(1) phaseDynamicMaxStep(19)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) phase(1) phaseTable(2) phaseEntry(1) phaseDynamicMaxStep(19)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) phase(1) phaseTable(2) phaseEntry(1) phaseDynamicMaxStep(19)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) phase(1) phaseTable(2) phaseEntry(1) phaseDynamicMaxStep(19)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) phase(1) phaseTable(2) phaseEntry(1) phaseDynamicMaxStep(19)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) asc(1) phase(1) phaseTable(2) phaseEntry(1) phaseDynamicMaxStep(19)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) asc(1) phase(1) phaseTable(2) phaseEntry(1) phaseDynamicMaxStep(19)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nema(1206) transportation(4) devices(2) asc(1) phase(1) phaseTable(2) phaseEntry(1) phaseDynamicMaxStep(19)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) nema(1206) transportation(4) devices(2) asc(1) phase(1) phaseTable(2) phaseEntry(1) phaseDynamicMaxStep(19)}
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/2/1/1/2/1/19
  • /ISO/Identified-Organization/6/1/4/1/1206/4/2/1/1/2/1/19
  • /ISO/3/6/1/4/1/1206/4/2/1/1/2/1/19
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/asc/phase/phaseTable/phaseEntry/phaseDynamicMaxStep
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/asc/phase/phaseTable/phaseEntry/phaseDynamicMaxStep
  • /iso/identified-organization/dod/internet/private/enterprises/1206/transportation/devices/asc/phase/phaseTable/phaseEntry/phaseDynamicMaxStep
  • /iso/identified-organization/dod/internet/private/enterprises/nema/transportation/devices/asc/phase/phaseTable/phaseEntry/phaseDynamicMaxStep
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1206/transportation/devices/asc/phase/phaseTable/phaseEntry/phaseDynamicMaxStep
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/nema/transportation/devices/asc/phase/phaseTable/phaseEntry/phaseDynamicMaxStep
  • /iso/identified-organization/dod/internet/private/vendor-objects/1206/transportation/devices/asc/phase/phaseTable/phaseEntry/phaseDynamicMaxStep
  • /iso/identified-organization/dod/internet/private/vendor-objects/nema/transportation/devices/asc/phase/phaseTable/phaseEntry/phaseDynamicMaxStep
  • /iso/org/dod/internet/private/enterprise/1206/transportation/devices/asc/phase/phaseTable/phaseEntry/phaseDynamicMaxStep
  • /iso/org/dod/internet/private/enterprise/nema/transportation/devices/asc/phase/phaseTable/phaseEntry/phaseDynamicMaxStep
  • /iso/org/dod/internet/private/enterprises/1206/transportation/devices/asc/phase/phaseTable/phaseEntry/phaseDynamicMaxStep
  • /iso/org/dod/internet/private/enterprises/nema/transportation/devices/asc/phase/phaseTable/phaseEntry/phaseDynamicMaxStep
  • /iso/org/dod/internet/private/ldap-enterprise/1206/transportation/devices/asc/phase/phaseTable/phaseEntry/phaseDynamicMaxStep
  • /iso/org/dod/internet/private/ldap-enterprise/nema/transportation/devices/asc/phase/phaseTable/phaseEntry/phaseDynamicMaxStep
  • /iso/org/dod/internet/private/vendor-objects/1206/transportation/devices/asc/phase/phaseTable/phaseEntry/phaseDynamicMaxStep
  • /iso/org/dod/internet/private/vendor-objects/nema/transportation/devices/asc/phase/phaseTable/phaseEntry/phaseDynamicMaxStep
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory, optional

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — NTCIP published standard MIB annexes (reviewed modules)

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory
Allowed ranges
0–255

Variant 2 — NTCIP published standard MIB annexes (reviewed modules)

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
optional
Allowed ranges
0–255

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In NTCIP1202-v03, the row index phaseNumber is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.1206.4.2.1.1.2.1.19.<phaseNumber>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.1206.4.2.1.1.2.1.19

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 4 distinct definitions; some records may not include a definition.

Show 4 published definitions

phaseDynamicMaxStep · mandatory

phaseDynamicMaxStep   OBJECT-TYPE
      SYNTAX INTEGER (0..255)
      ACCESS read-write
      STATUS mandatory
      DESCRIPTION "<Definition> This object shall determine the automatic
            adjustment to the running max in tenth seconds (0-25.5)

                 When a phase maxes out twice in a row, and on each successive max
                 out thereafter, one dynamic max step value shall be added to the
                 running max until such addition would mean the running max was
                 greater than the larger of normal max or dynamic max limit.

                 When a phase gaps out twice in a row, and on each successive gap
                 out thereafter, one dynamic max step value shall be subtracted
                 from the running max until such subtraction would mean the
                 running max was less than the smaller of the normal max or the
                 dynamic max limit.

            If a phase gaps out in one cycle and maxes out in the next cycle,
            or vice versa, the running max will not change.
      <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.1.2.1.19
      <Object Type> P
      <Unit> tenth second"
::= { phaseEntry 19 }

phaseDynamicMaxStep · optional

phaseDynamicMaxStep   OBJECT-TYPE
   SYNTAX   INTEGER (0..255)
   ACCESS   read-write
   STATUS   optional
   DESCRIPTION
      "<Definition> This object shall determine the
       automatic adjustment to the running max in tenth
       seconds (0-25.5)

        When a phase maxes out twice in a row, and on each
        successive max out thereafter, one dynamic max step
        value shall be added to the running max until such
        addition would mean the running max was greater than
        the larger of normal max or dynamic max limit.

        When a phase gaps out twice in a row, and on each
        successive gap out thereafter, one dynamic max step
        value shall be subtracted from the running max until
        such subtraction would mean the running max was less
        than the smaller of the normal max or the dynamic max
        limit.

       If a phase gaps out in one cycle and maxes out in
       the next cycle, or vice versa, the running max will
       not change.
       <DescriptiveName> NTCIP-1202::ASC.phaseDynamicMaxStep
       <DataConceptType> Data Element
       <Unit> tenth second"
::= { phaseEntry 19 }

phaseDynamicMaxStep · optional

phaseDynamicMaxStep OBJECT-TYPE
         SYNTAX INTEGER (0..255)
         ACCESS read-write
         STATUS optional
         DESCRIPTION
             "This object shall determine the automatic adjustment to the running max in tenth seconds
             (0-25.5).
             When a phase maxes out twice in a row, and on each successive max out thereafter, one
             dynamic max step value shall be added to the running max until such addition would mean
             the running max was greater than the larger of normal max or dynamic max limit.
             When a phase gaps out twice in a row, and on each successive gap out thereafter, one
             dynamic max step value shall be subtracted from the running max until such subtraction
             would mean the running max was less than the smaller of the normal max or the dynamic
             max limit.
             If a phase gaps out in one cycle and maxes out in the next cycle, or vice versa, the running
             max will not change."
::= { phaseEntry 19 }

phaseDynamicMaxStep · mandatory

phaseDynamicMaxStep   OBJECT-TYPE
      SYNTAX INTEGER (0..255)
      ACCESS read-write
      STATUS mandatory
      DESCRIPTION "<Definition> This object shall determine the automatic
            adjustment to the running max in tenth seconds (0-25.5)

                 When a phase maxes out twice in a row, and on each successive max
                 out thereafter, one dynamic max step value shall be added to the
                 running max until such addition would mean the running max was
                 greater than the larger of normal max or dynamic max limit.

                 When a phase gaps out twice in a row, and on each successive gap
                 out thereafter, one dynamic max step value shall be subtracted
                 from the running max until such subtraction would mean the
                 running max was less than the smaller of the normal max or the
                 dynamic max limit.

            If a phase gaps out in one cycle and maxes out in the next cycle,
            or vice versa, the running max will not change.
      <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.1.2.1.19
      <Unit> tenth second"
::= { phaseEntry 19 }

Meaning

Descriptions

4 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

<Definition> This object shall determine the automatic adjustment to the running max in tenth seconds (0-25.5) When a phase maxes out twice in a row, and on each successive max out thereafter, one dynamic max step value shall be added to the running max until such addition would mean the running max was greater than the larger of normal max or dynamic max limit. When a phase gaps out twice in a row, and on each successive gap out thereafter, one dynamic max step value shall be subtracted from the running max until such subtraction would mean the running max was less than the smaller of the normal max or the dynamic max limit. If a phase gaps out in one cycle and maxes out in the next cycle, or vice versa, the running max will not change. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.1.2.1.19 <Object Type> P <Unit> tenth second

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 2

<Definition> This object shall determine the automatic adjustment to the running max in tenth seconds (0-25.5) When a phase maxes out twice in a row, and on each successive max out thereafter, one dynamic max step value shall be added to the running max until such addition would mean the running max was greater than the larger of normal max or dynamic max limit. When a phase gaps out twice in a row, and on each successive gap out thereafter, one dynamic max step value shall be subtracted from the running max until such subtraction would mean the running max was less than the smaller of the normal max or the dynamic max limit. If a phase gaps out in one cycle and maxes out in the next cycle, or vice versa, the running max will not change. <DescriptiveName> NTCIP-1202::ASC.phaseDynamicMaxStep <DataConceptType> Data Element <Unit> tenth second

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 3

This object shall determine the automatic adjustment to the running max in tenth seconds (0-25.5). When a phase maxes out twice in a row, and on each successive max out thereafter, one dynamic max step value shall be added to the running max until such addition would mean the running max was greater than the larger of normal max or dynamic max limit. When a phase gaps out twice in a row, and on each successive gap out thereafter, one dynamic max step value shall be subtracted from the running max until such subtraction would mean the running max was less than the smaller of the normal max or the dynamic max limit. If a phase gaps out in one cycle and maxes out in the next cycle, or vice versa, the running max will not change.

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 4

<Definition> This object shall determine the automatic adjustment to the running max in tenth seconds (0-25.5) When a phase maxes out twice in a row, and on each successive max out thereafter, one dynamic max step value shall be added to the running max until such addition would mean the running max was greater than the larger of normal max or dynamic max limit. When a phase gaps out twice in a row, and on each successive gap out thereafter, one dynamic max step value shall be subtracted from the running max until such subtraction would mean the running max was less than the smaller of the normal max or the dynamic max limit. If a phase gaps out in one cycle and maxes out in the next cycle, or vice versa, the running max will not change. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.1.2.1.19 <Unit> tenth second

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

4 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 1

phaseDynamicMaxStep · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: phaseDynamicMaxStep

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "phaseDynamicMaxStep",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "255",
    ")",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> This object shall determine the automatic adjustment to the running max in tenth seconds (0-25.5) When a phase maxes out twice in a row, and on each successive max out thereafter, one dynamic max step value shall be added to the running max until such addition would mean the running max was greater than the larger of normal max or dynamic max limit. When a phase gaps out twice in a row, and on each successive gap out thereafter, one dynamic max step value shall be subtracted from the running max until such subtraction would mean the running max was less than the smaller of the normal max or the dynamic max limit. If a phase gaps out in one cycle and maxes out in the next cycle, or vice versa, the running max will not change. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.1.2.1.19 <Object Type> P <Unit> tenth second\"",
    "::=",
    "{",
    "phaseEntry",
    "19",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            255
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> This object shall determine the automatic adjustment to the running max in tenth seconds (0-25.5) When a phase maxes out twice in a row, and on each successive max out thereafter, one dynamic max step value shall be added to the running max until such addition would mean the running max was greater than the larger of normal max or dynamic max limit. When a phase gaps out twice in a row, and on each successive gap out thereafter, one dynamic max step value shall be subtracted from the running max until such subtraction would mean the running max was less than the smaller of the normal max or the dynamic max limit. If a phase gaps out in one cycle and maxes out in the next cycle, or vice versa, the running max will not change. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.1.2.1.19 <Object Type> P <Unit> tenth second"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 2NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 2

phaseDynamicMaxStep · optionalNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: optional.

Names: phaseDynamicMaxStep

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "phaseDynamicMaxStep",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "255",
    ")",
    "ACCESS",
    "read-write",
    "STATUS",
    "optional",
    "DESCRIPTION",
    "\"<Definition> This object shall determine the automatic adjustment to the running max in tenth seconds (0-25.5) When a phase maxes out twice in a row, and on each successive max out thereafter, one dynamic max step value shall be added to the running max until such addition would mean the running max was greater than the larger of normal max or dynamic max limit. When a phase gaps out twice in a row, and on each successive gap out thereafter, one dynamic max step value shall be subtracted from the running max until such subtraction would mean the running max was less than the smaller of the normal max or the dynamic max limit. If a phase gaps out in one cycle and maxes out in the next cycle, or vice versa, the running max will not change. <DescriptiveName> NTCIP-1202::ASC.phaseDynamicMaxStep <DataConceptType> Data Element <Unit> tenth second\"",
    "::=",
    "{",
    "phaseEntry",
    "19",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            255
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "optional"
    ],
    [
      "DESCRIPTION",
      "<Definition> This object shall determine the automatic adjustment to the running max in tenth seconds (0-25.5) When a phase maxes out twice in a row, and on each successive max out thereafter, one dynamic max step value shall be added to the running max until such addition would mean the running max was greater than the larger of normal max or dynamic max limit. When a phase gaps out twice in a row, and on each successive gap out thereafter, one dynamic max step value shall be subtracted from the running max until such subtraction would mean the running max was less than the smaller of the normal max or the dynamic max limit. If a phase gaps out in one cycle and maxes out in the next cycle, or vice versa, the running max will not change. <DescriptiveName> NTCIP-1202::ASC.phaseDynamicMaxStep <DataConceptType> Data Element <Unit> tenth second"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 3NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 3

phaseDynamicMaxStep · optionalNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: optional.

Names: phaseDynamicMaxStep

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "phaseDynamicMaxStep",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "255",
    ")",
    "ACCESS",
    "read-write",
    "STATUS",
    "optional",
    "DESCRIPTION",
    "\"This object shall determine the automatic adjustment to the running max in tenth seconds (0-25.5). When a phase maxes out twice in a row, and on each successive max out thereafter, one dynamic max step value shall be added to the running max until such addition would mean the running max was greater than the larger of normal max or dynamic max limit. When a phase gaps out twice in a row, and on each successive gap out thereafter, one dynamic max step value shall be subtracted from the running max until such subtraction would mean the running max was less than the smaller of the normal max or the dynamic max limit. If a phase gaps out in one cycle and maxes out in the next cycle, or vice versa, the running max will not change.\"",
    "::=",
    "{",
    "phaseEntry",
    "19",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            255
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "optional"
    ],
    [
      "DESCRIPTION",
      "This object shall determine the automatic adjustment to the running max in tenth seconds (0-25.5). When a phase maxes out twice in a row, and on each successive max out thereafter, one dynamic max step value shall be added to the running max until such addition would mean the running max was greater than the larger of normal max or dynamic max limit. When a phase gaps out twice in a row, and on each successive gap out thereafter, one dynamic max step value shall be subtracted from the running max until such subtraction would mean the running max was less than the smaller of the normal max or the dynamic max limit. If a phase gaps out in one cycle and maxes out in the next cycle, or vice versa, the running max will not change."
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 4NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 4

phaseDynamicMaxStep · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: phaseDynamicMaxStep

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "phaseDynamicMaxStep",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "0",
    ".",
    ".",
    "255",
    ")",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition> This object shall determine the automatic adjustment to the running max in tenth seconds (0-25.5) When a phase maxes out twice in a row, and on each successive max out thereafter, one dynamic max step value shall be added to the running max until such addition would mean the running max was greater than the larger of normal max or dynamic max limit. When a phase gaps out twice in a row, and on each successive gap out thereafter, one dynamic max step value shall be subtracted from the running max until such subtraction would mean the running max was less than the smaller of the normal max or the dynamic max limit. If a phase gaps out in one cycle and maxes out in the next cycle, or vice versa, the running max will not change. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.1.2.1.19 <Unit> tenth second\"",
    "::=",
    "{",
    "phaseEntry",
    "19",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            0,
            255
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition> This object shall determine the automatic adjustment to the running max in tenth seconds (0-25.5) When a phase maxes out twice in a row, and on each successive max out thereafter, one dynamic max step value shall be added to the running max until such addition would mean the running max was greater than the larger of normal max or dynamic max limit. When a phase gaps out twice in a row, and on each successive gap out thereafter, one dynamic max step value shall be subtracted from the running max until such subtraction would mean the running max was less than the smaller of the normal max or the dynamic max limit. If a phase gaps out in one cycle and maxes out in the next cycle, or vice versa, the running max will not change. <Object Identifier> 1.3.6.1.4.1.1206.4.2.1.1.2.1.19 <Unit> tenth second"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Siblings (33)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.2.1.1.2.1.1 phaseNumber00
1.3.6.1.4.1.1206.4.2.1.1.2.1.2 phaseWalk00
1.3.6.1.4.1.1206.4.2.1.1.2.1.3 phasePedestrianClear00
1.3.6.1.4.1.1206.4.2.1.1.2.1.4 phaseMinimumGreen00
1.3.6.1.4.1.1206.4.2.1.1.2.1.5 phasePassage00
1.3.6.1.4.1.1206.4.2.1.1.2.1.6 phaseMaximum100
1.3.6.1.4.1.1206.4.2.1.1.2.1.7 phaseMaximum200
1.3.6.1.4.1.1206.4.2.1.1.2.1.8 phaseYellowChange00
1.3.6.1.4.1.1206.4.2.1.1.2.1.9 phaseRedClear00
1.3.6.1.4.1.1206.4.2.1.1.2.1.10 phaseRedRevert00
1.3.6.1.4.1.1206.4.2.1.1.2.1.11 phaseAddedInitial00
1.3.6.1.4.1.1206.4.2.1.1.2.1.12 phaseMaximumInitial00
1.3.6.1.4.1.1206.4.2.1.1.2.1.13 phaseTimeBeforeReduction00
1.3.6.1.4.1.1206.4.2.1.1.2.1.14 phaseCarsBeforeReduction00
1.3.6.1.4.1.1206.4.2.1.1.2.1.15 phaseTimeToReduce00
1.3.6.1.4.1.1206.4.2.1.1.2.1.16 phaseReduceBy00
1.3.6.1.4.1.1206.4.2.1.1.2.1.17 phaseMinimumGap00
1.3.6.1.4.1.1206.4.2.1.1.2.1.18 phaseDynamicMaxLimit00
1.3.6.1.4.1.1206.4.2.1.1.2.1.20 phaseStartup00
1.3.6.1.4.1.1206.4.2.1.1.2.1.21 phaseOptions00
1.3.6.1.4.1.1206.4.2.1.1.2.1.22 phaseRing00
1.3.6.1.4.1.1206.4.2.1.1.2.1.23 phaseConcurrency00
1.3.6.1.4.1.1206.4.2.1.1.2.1.24 phaseMaximum300
1.3.6.1.4.1.1206.4.2.1.1.2.1.25 phaseYellowandRedChangeTimeBeforeEndPedClear00
1.3.6.1.4.1.1206.4.2.1.1.2.1.26 phasePedWalkService00
1.3.6.1.4.1.1206.4.2.1.1.2.1.27 phaseDontWalkRevert00
1.3.6.1.4.1.1206.4.2.1.1.2.1.28 phasePedAlternateClearance00
1.3.6.1.4.1.1206.4.2.1.1.2.1.29 phasePedAlternateWalk00
1.3.6.1.4.1.1206.4.2.1.1.2.1.30 phasePedAdvanceWalkTime00
1.3.6.1.4.1.1206.4.2.1.1.2.1.31 phasePedDelayTime00
1.3.6.1.4.1.1206.4.2.1.1.2.1.32 phaseAdvWarnGrnStartTime00
1.3.6.1.4.1.1206.4.2.1.1.2.1.33 phaseAdvWarnRedStartTime00
1.3.6.1.4.1.1206.4.2.1.1.2.1.34 phaseAltMinTimeTransition00