Reference record for OID 1.3.6.1.4.1.318.1.1.1.6.2.2



parent
1.3.6.1.4.1.318.1.1.1.6.2 (upsAdvControl)
node code
2
node names
  • upsAdvControlRebootShutdownUps
  • upsAdvControlRebootUps
  • dot oid
    1.3.6.1.4.1.318.1.1.1.6.2.2
    type
    OBJECT-TYPE
    asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ups(1) upsControl(6) upsAdvControl(2) upsAdvControlRebootShutdownUps(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ups(1) upsControl(6) upsAdvControl(2) upsAdvControlRebootUps(2)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ups(1) upsControl(6) upsAdvControl(2) upsAdvControlRebootShutdownUps(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ups(1) upsControl(6) upsAdvControl(2) upsAdvControlRebootUps(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ups(1) upsControl(6) upsAdvControl(2) upsAdvControlRebootShutdownUps(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ups(1) upsControl(6) upsAdvControl(2) upsAdvControlRebootUps(2)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ups(1) upsControl(6) upsAdvControl(2) upsAdvControlRebootShutdownUps(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ups(1) upsControl(6) upsAdvControl(2) upsAdvControlRebootUps(2)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/apc/products/hardware/ups/upsControl/upsAdvControl/upsAdvControlRebootShutdownUps
  • /iso/identified-organization/dod/internet/private/enterprise/apc/products/hardware/ups/upsControl/upsAdvControl/upsAdvControlRebootUps
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/apc/products/hardware/ups/upsControl/upsAdvControl/upsAdvControlRebootShutdownUps
  • /iso/org/dod/internet/private/enterprise/apc/products/hardware/ups/upsControl/upsAdvControl/upsAdvControlRebootUps
  • /iso/org/dod/internet/private/enterprises/apc/products/hardware/ups/upsControl/upsAdvControl/upsAdvControlRebootShutdownUps
  • /iso/org/dod/internet/private/enterprises/apc/products/hardware/ups/upsControl/upsAdvControl/upsAdvControlRebootUps
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/apc/products/hardware/ups/upsControl/upsAdvControl/upsAdvControlRebootShutdownUps
  • /iso/iso-identified-organization/dod/internet/private/enterprises/apc/products/hardware/ups/upsControl/upsAdvControl/upsAdvControlRebootUps
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/318/1/1/1/6/2/2

    Description by mibdepot

    Setting this value to noRebootUps(1) has no effect.

    Setting this variable to rebootUps(2) causes the
    UPS to shut off and turn back on.

    Setting this variable to rebootUpsGracefully(3) causes the
    UPS to shut off and turn back on after a delay period.
    This allows the host to shut down in a graceful manner.

    The value noRebootUps(1) will always be returned
    when the variable is read.

    Parsed from file powernet.mib.txt
    Company: None
    Module: PowerNet-MIB

    Description by circitor

    Setting this variable to rebootShutdownUps(2) causes the UPS
    to shut off and turn back on (as long as good AC input power
    is available, otherwise the UPS will remain off until good AC
    input power is available).

    Setting this variable to rebootShutdownUpsGracefully(3) causes
    the UPS to shut off after a delay period and then turn back
    on. This allows the host to shut down in a graceful manner.

    If this UPS is an active member of a Synchronized Control
    Group (SCG) the rebootShutdownSyncGroupUps(4) command will
    perform a Synchronized Reboot of all active Group members
    regardless of their current AC output status. If applicable,
    this unit's Power Synchronization Delay, Shutdown Delay,
    Return Delay, Return Battery Capacity, and Return Battery
    Capacity Offset will be used to execute the Reboot command.

    If this UPS is an active member of a SCG the
    rebootShutdownSyncGroupUpsGracefully(5) command will perform
    a Synchronized Reboot of all active Group members regardless
    of their current AC output status. If applicable, this unit's
    Power Synchronization Delay, Maximum Shutdown Time, Shutdown
    Delay, Return Delay, Return Battery Capacity, and Return
    Battery Capacity Offset will be used to execute the Reboot
    command.

    Setting this value to noRebootShutdownUps(1) has no effect.

    The value noRebootShutdownUps(1) will always be returned when
    the variable is read.

    Parsed from file PowerNet-MIB.mib
    Module: PowerNet-MIB

    Information by mibdepot

    upsAdvControlRebootUps OBJECT-TYPE SYNTAX INTEGER { noRebootUps(1), rebootUps(2), rebootUpsGracefully(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this value to noRebootUps(1) has no effect. Setting this variable to rebootUps(2) causes the UPS to shut off and turn back on. Setting this variable to rebootUpsGracefully(3) causes the UPS to shut off and turn back on after a delay period. This allows the host to shut down in a graceful manner. The value noRebootUps(1) will always be returned when the variable is read." ::= { upsAdvControl 2 }

    Information by oid_info

    Vendor: American Power Conversion Corp.
    Module: PowerNet-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    upsAdvControlRebootShutdownUps OBJECT-TYPE SYNTAX INTEGER { noRebootShutdownUps(1), rebootShutdownUps(2), rebootShutdownUpsGracefully(3), rebootShutdownSyncGroupUps(4), rebootShutdownSyncGroupUpsGracefully(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Setting this variable to rebootShutdownUps(2) causes the UPS to shut off and turn back on (as long as good AC input power is available, otherwise the UPS will remain off until good AC input power is available). Setting this variable to rebootShutdownUpsGracefully(3) causes the UPS to shut off after a delay period and then turn back on. This allows the host to shut down in a graceful manner. If this UPS is an active member of a Synchronized Control Group (SCG) the rebootShutdownSyncGroupUps(4) command will perform a Synchronized Reboot of all active Group members regardless of their current AC output status. If applicable, this unit's Power Synchronization Delay, Shutdown Delay, Return Delay, Return Battery Capacity, and Return Battery Capacity Offset will be used to execute the Reboot command. If this UPS is an active member of a SCG the rebootShutdownSyncGroupUpsGracefully(5) command will perform a Synchronized Reboot of all active Group members regardless of their current AC output status. If applicable, this unit's Power Synchronization Delay, Maximum Shutdown Time, Shutdown Delay, Return Delay, Return Battery Capacity, and Return Battery Capacity Offset will be used to execute the Reboot command. Setting this value to noRebootShutdownUps(1) has no effect. The value noRebootShutdownUps(1) will always be returned when the variable is read." ::= { upsAdvControl 2 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.318)

    Yoest Peter C.

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.1.6.2.2.0 upsAdvControlRebootUps 0 0 None

    Brothers (8)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.1.6.2.1 upsAdvControlUpsOff 1 1 Setting this variable to turnUpsOff(2) causes
    the UPS to shut off. When in this state, the UPS
    will not provide output power reg…
    1.3.6.1.4.1.318.1.1.1.6.2.3 upsAdvControlUpsSleep 1 1 Setting this value to noPutUpsToSleep(1) has no
    effect.

    Setting this variable to putUpsToSleep(2) causes
    the UPS to go to sleep f…
    1.3.6.1.4.1.318.1.1.1.6.2.4 upsAdvControlSimulatePowerFail 1 1 Setting this variable to simulatePowerFailure(2) causes
    the UPS switch to battery power.

    Setting this value to noSimulatePowerFai…
    1.3.6.1.4.1.318.1.1.1.6.2.5 upsAdvControlFlashAndBeep 1 1 Setting this variable to flashAndBeep(2) causes the
    UPS to beep and simultaneously turn on the UPS front
    panel lights (Smart-UPS …
    1.3.6.1.4.1.318.1.1.1.6.2.6 upsAdvControlTurnOnUPS 1 1 Setting this variable to turnOnUPS(2) causes the
    UPS to be turned on immediately, provided
    upsBasicOutputStatus does not read ON.…
    1.3.6.1.4.1.318.1.1.1.6.2.7 upsAdvControlBypassSwitch 1 1 This switch puts the UPS in or out of bypass mode.
    1.3.6.1.4.1.318.1.1.1.6.2.8 upsAdvControlRebootUpsWithOrWithoutAC 1 1 Setting this variable to rebootUpsImmediatelyWithOrWithoutAC (2)
    causes the UPS to turn off immediately, wait for a minimum time…
    1.3.6.1.4.1.318.1.1.1.6.2.9 upsAdvControlFirmwareUpdate 1 1 Setting this variable to firmwareUpdate(2) causes the
    UPS to begin a firmware update if possible.

    Setting this value to noFirmwa…