Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"docsRphyRpdIfEnetSfpPlusStatusStatus",
"OBJECT-TYPE",
"SYNTAX",
"BITS",
"{",
"unknown",
"(",
"0",
")",
",",
"notInstalled",
"(",
"1",
")",
",",
"installed",
"(",
"2",
")",
",",
"faulty",
"(",
"3",
")",
",",
"operational",
"(",
"4",
")",
",",
"enabled",
"(",
"5",
")",
",",
"disabled",
"(",
"6",
")",
",",
"invalidCcBase",
"(",
"7",
")",
",",
"invalidCcExt",
"(",
"8",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"This attribute reports the current state of the SFP+ transceiver. The following state information can be reported: unknown: The state is unknown. notInstalled: The SFP+ transceiver is not installed. installed: The SFP+ transceiver has been installed. faulty: The SFP+ transceiver is faulty. operational: The SFP+ transceiver is working properly. enabled: The SFP+ transceiver has been enabled. disabled: The SFP+ transceiver has been diabled. invalidCcBase: indicates that the first 64 bytes of serial information in the SFP+ transceiver is invalid. The check is done by comparing the 64-th byte with the sum of the contents of the first 63 bytes (bytes 0 to 62, inclusive). invalidCcExt: indicates that the first 32 bytes of the extended serial information in the SFP+ transceiver is invalid. The check is done by comparing the 95-th byte with the sum of the contents of the first 32 bytes (bytes 64 to 94, inclusive).\"",
"::=",
"{",
"docsRphyRpdIfEnetSfpPlusStatusEntry",
"1",
"}"
],
"syntax_tree": [
[
"BITS",
[
[
"unknown",
0
],
[
"notInstalled",
1
],
[
"installed",
2
],
[
"faulty",
3
],
[
"operational",
4
],
[
"enabled",
5
],
[
"disabled",
6
],
[
"invalidCcBase",
7
],
[
"invalidCcExt",
8
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This attribute reports the current state of the SFP+ transceiver. The following state information can be reported: unknown: The state is unknown. notInstalled: The SFP+ transceiver is not installed. installed: The SFP+ transceiver has been installed. faulty: The SFP+ transceiver is faulty. operational: The SFP+ transceiver is working properly. enabled: The SFP+ transceiver has been enabled. disabled: The SFP+ transceiver has been diabled. invalidCcBase: indicates that the first 64 bytes of serial information in the SFP+ transceiver is invalid. The check is done by comparing the 64-th byte with the sum of the contents of the first 63 bytes (bytes 0 to 62, inclusive). invalidCcExt: indicates that the first 32 bytes of the extended serial information in the SFP+ transceiver is invalid. The check is done by comparing the 95-th byte with the sum of the contents of the first 32 bytes (bytes 64 to 94, inclusive)."
],
null,
null,
null,
null
]
}