Reference record for OID 1.3.6.1.4.1.4491.2.1.30.1.2.8.1.22

Parent
1.3.6.1.4.1.4491.2.1.30.1.2.8.1 (docsRphyRpdIfEnetSfpPlusStatusEntry)
Node code
22
Node name
docsRphyRpdIfEnetSfpPlusStatusOptions
Numeric OID
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.22
URN notation
urn:oid:1.3.6.1.4.1.4491.2.1.30.1.2.8.1.22
ASN.1 notation

{1 3 6 1 4 1 4491 2 1 30 1 2 8 1 22}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusOptions(22)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusOptions(22)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusOptions(22)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusOptions(22)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusOptions(22)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusOptions(22)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusOptions(22)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusOptions(22)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusOptions(22)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusOptions(22)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusOptions(22)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusOptions(22)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusOptions(22)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusOptions(22)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusOptions(22)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusOptions(22)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/4491/2/1/30/1/2/8/1/22
  • /ISO/Identified-Organization/6/1/4/1/4491/2/1/30/1/2/8/1/22
  • /ISO/3/6/1/4/1/4491/2/1/30/1/2/8/1/22
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusOptions
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusOptions
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusOptions
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusOptions
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusOptions
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusOptions
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusOptions
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusOptions
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusOptions
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusOptions
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusOptions
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusOptions
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusOptions
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusOptions
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusOptions
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusOptions
  • Additional combinations skipped.

Descriptions

docsRphyRpdIfEnetSfpPlusStatusOptions — CableLabs official current and historical MIBs

This attribute reports options implemented in the transceiver. Note: The encoding of bit values of this attribute reflects the inverse bit numbering convention of the SFF specification.

docsRphyRpdIfEnetSfpPlusStatusOptions — CableLabs official current and historical MIBs

This attribute reports options implemented in the transceiver.

docsRphyRpdIfEnetSfpPlusStatusOptions — CableLabs official current and historical MIBs

This attribute reports options implemented in the transceiver as described in the Options Values table of [SFF 8472]. The following rate identifier types can be reported: unallocated: unallocated options value rxlosNormal: Loss of Signal implemented, behavior as defined in [SFF 8419] (often called Rx_LOS) rxlosInverted: Loss of Signal implemented, signal inverted from standard definition in SFP MSA (often called Signal Detect) txFault: TX_FAULT signal implemented. Reference [SFF 8419] txDisable: TX_DISABLE is implemented and disables the high speed serial output. rateSelect: RATE_SELECT functionality is implemented. unallocated6: unallocated options value unallocated7: unallocated options value powerLevel: Power Level Declaration. Value of zero identifies Power Level 1 (or unspecified) requirements. Value of one identifies Power Level 2 requirement. See [SFF 8472] I/O Timing for Soft Control and Status Functions table and Extended Module Control/Status Bytes table for control, status, timing. See [SFF 8472] Option Values table Address A0h byte 64, Bit 5 for Power Level 3 declaration. See [SFF 8472] Option Values table Address A0h byte 64, Bit 6 for Power Level 4 declaration. Reference [SFF 8431]. cooledTransceiver: Cooled Transceiver Declaration. Value of zero identifies a conventional uncooled (or unspecified) laser implementation. Value of one identifies a cooled laser transmitter implementation. Reference [SFF 8431]. Reference [SFF 8472]

Source records

docsRphyRpdIfEnetSfpPlusStatusOptions

Status in source: current.

Names: docsRphyRpdIfEnetSfpPlusStatusOptions

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyRpdIfEnetSfpPlusStatusOptions",
    "OBJECT-TYPE",
    "SYNTAX",
    "BITS",
    "{",
    "reserved0",
    "(",
    "0",
    ")",
    ",",
    "reserved1",
    "(",
    "1",
    ")",
    ",",
    "reserved2",
    "(",
    "2",
    ")",
    ",",
    "reserved3",
    "(",
    "3",
    ")",
    ",",
    "reserved4",
    "(",
    "4",
    ")",
    ",",
    "cooledTransceiver",
    "(",
    "5",
    ")",
    ",",
    "powerLevel",
    "(",
    "6",
    ")",
    ",",
    "linearOutput",
    "(",
    "7",
    ")",
    ",",
    "unallocated7",
    "(",
    "8",
    ")",
    ",",
    "unallocated6",
    "(",
    "9",
    ")",
    ",",
    "rateSelect",
    "(",
    "10",
    ")",
    ",",
    "txDisable",
    "(",
    "11",
    ")",
    ",",
    "txFault",
    "(",
    "12",
    ")",
    ",",
    "rxlosInverted",
    "(",
    "13",
    ")",
    ",",
    "rxlosNormal",
    "(",
    "14",
    ")",
    ",",
    "unallocated0",
    "(",
    "15",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This attribute reports options implemented in the transceiver. Note: The encoding of bit values of this attribute reflects the inverse bit numbering convention of the SFF specification.\"",
    "::=",
    "{",
    "docsRphyRpdIfEnetSfpPlusStatusEntry",
    "22",
    "}"
  ],
  "syntax_tree": [
    [
      "BITS",
      [
        [
          "reserved0",
          0
        ],
        [
          "reserved1",
          1
        ],
        [
          "reserved2",
          2
        ],
        [
          "reserved3",
          3
        ],
        [
          "reserved4",
          4
        ],
        [
          "cooledTransceiver",
          5
        ],
        [
          "powerLevel",
          6
        ],
        [
          "linearOutput",
          7
        ],
        [
          "unallocated7",
          8
        ],
        [
          "unallocated6",
          9
        ],
        [
          "rateSelect",
          10
        ],
        [
          "txDisable",
          11
        ],
        [
          "txFault",
          12
        ],
        [
          "rxlosInverted",
          13
        ],
        [
          "rxlosNormal",
          14
        ],
        [
          "unallocated0",
          15
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This attribute reports options implemented in the transceiver. Note: The encoding of bit values of this attribute reflects the inverse bit numbering convention of the SFF specification."
    ],
    null,
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2020-05-21.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusOptions  OBJECT-TYPE
        SYNTAX      BITS {
                          reserved0(0),
                          reserved1(1),
                          reserved2(2),
                          reserved3(3),
                          reserved4(4),
                          cooledTransceiver(5),
                          powerLevel(6),
                          linearOutput(7),
                          unallocated7(8),
                          unallocated6(9),
                          rateSelect(10),
                          txDisable(11),
                          txFault(12),
                          rxlosInverted(13),
                          rxlosNormal(14),
                          unallocated0(15)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports options implemented in the
             transceiver. Note: The encoding of bit values of this 
             attribute reflects the inverse bit numbering 
             convention of the SFF specification."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 22 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2020-05-21.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusOptions.
    Source version and references

    Downloaded: 2026-10-26T22:49:56.205690+00:00.

docsRphyRpdIfEnetSfpPlusStatusOptions

Status in source: current.

Names: docsRphyRpdIfEnetSfpPlusStatusOptions

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyRpdIfEnetSfpPlusStatusOptions",
    "OBJECT-TYPE",
    "SYNTAX",
    "BITS",
    "{",
    "unallocated0",
    "(",
    "0",
    ")",
    ",",
    "rxlosNormal",
    "(",
    "1",
    ")",
    ",",
    "rxlosInverted",
    "(",
    "2",
    ")",
    ",",
    "txFault",
    "(",
    "3",
    ")",
    ",",
    "txDisable",
    "(",
    "4",
    ")",
    ",",
    "rateSelect",
    "(",
    "5",
    ")",
    ",",
    "unallocated6",
    "(",
    "6",
    ")",
    ",",
    "unallocated7",
    "(",
    "7",
    ")",
    ",",
    "linearOutput",
    "(",
    "8",
    ")",
    ",",
    "powerLevel",
    "(",
    "9",
    ")",
    ",",
    "cooledTransceiver",
    "(",
    "10",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This attribute reports options implemented in the transceiver.\"",
    "::=",
    "{",
    "docsRphyRpdIfEnetSfpPlusStatusEntry",
    "22",
    "}"
  ],
  "syntax_tree": [
    [
      "BITS",
      [
        [
          "unallocated0",
          0
        ],
        [
          "rxlosNormal",
          1
        ],
        [
          "rxlosInverted",
          2
        ],
        [
          "txFault",
          3
        ],
        [
          "txDisable",
          4
        ],
        [
          "rateSelect",
          5
        ],
        [
          "unallocated6",
          6
        ],
        [
          "unallocated7",
          7
        ],
        [
          "linearOutput",
          8
        ],
        [
          "powerLevel",
          9
        ],
        [
          "cooledTransceiver",
          10
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This attribute reports options implemented in the transceiver."
    ],
    null,
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2019-01-24.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusOptions  OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
    		      rxlosNormal(1),
    		      rxlosInverted(2),
    		      txFault(3),
    		      txDisable(4),
    		      rateSelect(5),
    		      unallocated6(6),
    		      unallocated7(7),
    		      linearOutput(8),
    		      powerLevel(9),
    		      cooledTransceiver(10)
                     }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "This attribute reports options implemented in the transceiver."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 22 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2019-01-24.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusOptions.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.074775+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2019-06-13.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusOptions  OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          rxlosNormal(1),
                          rxlosInverted(2),
                          txFault(3),
                          txDisable(4),
                          rateSelect(5),
                          unallocated6(6),
                          unallocated7(7),
                          linearOutput(8),
                          powerLevel(9),
                          cooledTransceiver(10)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports options implemented in the transceiver."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 22 }
    Module imports
    {'IF-MIB': ['InterfaceIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2019-06-13.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusOptions.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.180890+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2019-09-26.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusOptions  OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          rxlosNormal(1),
                          rxlosInverted(2),
                          txFault(3),
                          txDisable(4),
                          rateSelect(5),
                          unallocated6(6),
                          unallocated7(7),
                          linearOutput(8),
                          powerLevel(9),
                          cooledTransceiver(10)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports options implemented in the transceiver."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 22 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2019-09-26.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusOptions.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.289076+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2020-01-09.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusOptions  OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          rxlosNormal(1),
                          rxlosInverted(2),
                          txFault(3),
                          txDisable(4),
                          rateSelect(5),
                          unallocated6(6),
                          unallocated7(7),
                          linearOutput(8),
                          powerLevel(9),
                          cooledTransceiver(10)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports options implemented in the transceiver."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 22 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2020-01-09.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusOptions.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.938082+00:00.

docsRphyRpdIfEnetSfpPlusStatusOptions

Status in source: current.

Names: docsRphyRpdIfEnetSfpPlusStatusOptions

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyRpdIfEnetSfpPlusStatusOptions",
    "OBJECT-TYPE",
    "SYNTAX",
    "BITS",
    "{",
    "unallocated0",
    "(",
    "0",
    ")",
    ",",
    "rxlosNormal",
    "(",
    "1",
    ")",
    ",",
    "rxlosInverted",
    "(",
    "2",
    ")",
    ",",
    "txFault",
    "(",
    "3",
    ")",
    ",",
    "txDisable",
    "(",
    "4",
    ")",
    ",",
    "rateSelect",
    "(",
    "5",
    ")",
    ",",
    "unallocated6",
    "(",
    "6",
    ")",
    ",",
    "unallocated7",
    "(",
    "7",
    ")",
    ",",
    "linearOutput",
    "(",
    "8",
    ")",
    ",",
    "powerLevel",
    "(",
    "9",
    ")",
    ",",
    "cooledTransceiver",
    "(",
    "10",
    ")",
    ",",
    "reserved11",
    "(",
    "11",
    ")",
    ",",
    "reserved12",
    "(",
    "12",
    ")",
    ",",
    "reserved13",
    "(",
    "13",
    ")",
    ",",
    "reserved14",
    "(",
    "14",
    ")",
    ",",
    "reserved15",
    "(",
    "15",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This attribute reports options implemented in the transceiver.\"",
    "::=",
    "{",
    "docsRphyRpdIfEnetSfpPlusStatusEntry",
    "22",
    "}"
  ],
  "syntax_tree": [
    [
      "BITS",
      [
        [
          "unallocated0",
          0
        ],
        [
          "rxlosNormal",
          1
        ],
        [
          "rxlosInverted",
          2
        ],
        [
          "txFault",
          3
        ],
        [
          "txDisable",
          4
        ],
        [
          "rateSelect",
          5
        ],
        [
          "unallocated6",
          6
        ],
        [
          "unallocated7",
          7
        ],
        [
          "linearOutput",
          8
        ],
        [
          "powerLevel",
          9
        ],
        [
          "cooledTransceiver",
          10
        ],
        [
          "reserved11",
          11
        ],
        [
          "reserved12",
          12
        ],
        [
          "reserved13",
          13
        ],
        [
          "reserved14",
          14
        ],
        [
          "reserved15",
          15
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This attribute reports options implemented in the transceiver."
    ],
    null,
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2020-10-01.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusOptions  OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          rxlosNormal(1),
                          rxlosInverted(2),
                          txFault(3),
                          txDisable(4),
                          rateSelect(5),
                          unallocated6(6),
                          unallocated7(7),
                          linearOutput(8),
                          powerLevel(9),
                          cooledTransceiver(10),
                          reserved11(11),
                          reserved12(12),
                          reserved13(13),
                          reserved14(14),
                          reserved15(15)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports options implemented in the
             transceiver."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 22 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2020-10-01.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusOptions.
    Source version and references

    Downloaded: 2026-10-26T22:49:56.354948+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2021-03-11.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusOptions  OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          rxlosNormal(1),
                          rxlosInverted(2),
                          txFault(3),
                          txDisable(4),
                          rateSelect(5),
                          unallocated6(6),
                          unallocated7(7),
                          linearOutput(8),
                          powerLevel(9),
                          cooledTransceiver(10),
                          reserved11(11),
                          reserved12(12),
                          reserved13(13),
                          reserved14(14),
                          reserved15(15)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports options implemented in the
             transceiver."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 22 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2021-03-11.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusOptions.
    Source version and references

    Downloaded: 2026-10-26T22:49:56.429401+00:00.

docsRphyRpdIfEnetSfpPlusStatusOptions

Status in source: current.

Names: docsRphyRpdIfEnetSfpPlusStatusOptions

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyRpdIfEnetSfpPlusStatusOptions",
    "OBJECT-TYPE",
    "SYNTAX",
    "BITS",
    "{",
    "unallocated0",
    "(",
    "0",
    ")",
    ",",
    "rxlosNormal",
    "(",
    "1",
    ")",
    ",",
    "rxlosInverted",
    "(",
    "2",
    ")",
    ",",
    "txFault",
    "(",
    "3",
    ")",
    ",",
    "txDisable",
    "(",
    "4",
    ")",
    ",",
    "rateSelect",
    "(",
    "5",
    ")",
    ",",
    "unallocated6",
    "(",
    "6",
    ")",
    ",",
    "unallocated7",
    "(",
    "7",
    ")",
    ",",
    "linearOutput",
    "(",
    "8",
    ")",
    ",",
    "powerLevel",
    "(",
    "9",
    ")",
    ",",
    "cooledTransceiver",
    "(",
    "10",
    ")",
    ",",
    "reserved11",
    "(",
    "11",
    ")",
    ",",
    "reserved12",
    "(",
    "12",
    ")",
    ",",
    "reserved13",
    "(",
    "13",
    ")",
    ",",
    "reserved14",
    "(",
    "14",
    ")",
    ",",
    "reserved15",
    "(",
    "15",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This attribute reports options implemented in the transceiver as described in the Options Values table of [SFF 8472]. The following rate identifier types can be reported: unallocated: unallocated options value rxlosNormal: Loss of Signal implemented, behavior as defined in [SFF 8419] (often called Rx_LOS) rxlosInverted: Loss of Signal implemented, signal inverted from standard definition in SFP MSA (often called Signal Detect) txFault: TX_FAULT signal implemented. Reference [SFF 8419] txDisable: TX_DISABLE is implemented and disables the high speed serial output. rateSelect: RATE_SELECT functionality is implemented. unallocated6: unallocated options value unallocated7: unallocated options value powerLevel: Power Level Declaration. Value of zero identifies Power Level 1 (or unspecified) requirements. Value of one identifies Power Level 2 requirement. See [SFF 8472] I/O Timing for Soft Control and Status Functions table and Extended Module Control/Status Bytes table for control, status, timing. See [SFF 8472] Option Values table Address A0h byte 64, Bit 5 for Power Level 3 declaration. See [SFF 8472] Option Values table Address A0h byte 64, Bit 6 for Power Level 4 declaration. Reference [SFF 8431]. cooledTransceiver: Cooled Transceiver Declaration. Value of zero identifies a conventional uncooled (or unspecified) laser implementation. Value of one identifies a cooled laser transmitter implementation. Reference [SFF 8431]. Reference [SFF 8472]\"",
    "::=",
    "{",
    "docsRphyRpdIfEnetSfpPlusStatusEntry",
    "22",
    "}"
  ],
  "syntax_tree": [
    [
      "BITS",
      [
        [
          "unallocated0",
          0
        ],
        [
          "rxlosNormal",
          1
        ],
        [
          "rxlosInverted",
          2
        ],
        [
          "txFault",
          3
        ],
        [
          "txDisable",
          4
        ],
        [
          "rateSelect",
          5
        ],
        [
          "unallocated6",
          6
        ],
        [
          "unallocated7",
          7
        ],
        [
          "linearOutput",
          8
        ],
        [
          "powerLevel",
          9
        ],
        [
          "cooledTransceiver",
          10
        ],
        [
          "reserved11",
          11
        ],
        [
          "reserved12",
          12
        ],
        [
          "reserved13",
          13
        ],
        [
          "reserved14",
          14
        ],
        [
          "reserved15",
          15
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This attribute reports options implemented in the transceiver as described in the Options Values table of [SFF 8472]. The following rate identifier types can be reported: unallocated: unallocated options value rxlosNormal: Loss of Signal implemented, behavior as defined in [SFF 8419] (often called Rx_LOS) rxlosInverted: Loss of Signal implemented, signal inverted from standard definition in SFP MSA (often called Signal Detect) txFault: TX_FAULT signal implemented. Reference [SFF 8419] txDisable: TX_DISABLE is implemented and disables the high speed serial output. rateSelect: RATE_SELECT functionality is implemented. unallocated6: unallocated options value unallocated7: unallocated options value powerLevel: Power Level Declaration. Value of zero identifies Power Level 1 (or unspecified) requirements. Value of one identifies Power Level 2 requirement. See [SFF 8472] I/O Timing for Soft Control and Status Functions table and Extended Module Control/Status Bytes table for control, status, timing. See [SFF 8472] Option Values table Address A0h byte 64, Bit 5 for Power Level 3 declaration. See [SFF 8472] Option Values table Address A0h byte 64, Bit 6 for Power Level 4 declaration. Reference [SFF 8431]. cooledTransceiver: Cooled Transceiver Declaration. Value of zero identifies a conventional uncooled (or unspecified) laser implementation. Value of one identifies a cooled laser transmitter implementation. Reference [SFF 8431]. Reference [SFF 8472]"
    ],
    null,
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2021-10-21.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusOptions  OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          rxlosNormal(1),
                          rxlosInverted(2),
                          txFault(3),
                          txDisable(4),
                          rateSelect(5),
                          unallocated6(6),
                          unallocated7(7),
                          linearOutput(8),
                          powerLevel(9),
                          cooledTransceiver(10),
                          reserved11(11),
                          reserved12(12),
                          reserved13(13),
                          reserved14(14),
                          reserved15(15)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports options implemented in the transceiver 
            as described in the Options Values table of [SFF 8472]. 
            The following rate identifier types can be reported:
            unallocated: unallocated options value
            
            rxlosNormal: Loss of Signal implemented, behavior as defined in 
            [SFF 8419] (often called Rx_LOS)
            
            rxlosInverted: Loss of Signal implemented, signal inverted from
            standard definition in SFP MSA (often called Signal Detect)
            
            txFault: TX_FAULT signal implemented. Reference  [SFF 8419]        
            txDisable: TX_DISABLE is implemented and disables the high speed serial output.
            rateSelect: RATE_SELECT functionality is implemented.
            unallocated6: unallocated options value
            unallocated7: unallocated options value
            
            powerLevel: Power Level Declaration. Value of zero identifies Power 
            Level 1 (or unspecified) requirements. Value of one identifies Power
            Level 2 requirement. See [SFF 8472] I/O Timing for Soft Control and 
            Status Functions table and Extended Module Control/Status Bytes table 
            for control, status, timing. See [SFF 8472] Option Values table Address
            A0h byte 64, Bit 5 for Power Level 3 declaration. See [SFF 8472] Option 
            Values table Address A0h byte 64, Bit 6 for Power Level 4 declaration.
            Reference  [SFF 8431].
            
            cooledTransceiver: Cooled Transceiver Declaration. Value of zero identifies 
            a conventional uncooled (or unspecified) laser implementation. Value of one
            identifies a cooled laser transmitter implementation. Reference [SFF 8431].
            
            Reference [SFF 8472]"
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 22 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2021-10-21.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusOptions.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.003028+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-01-20.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusOptions  OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          rxlosNormal(1),
                          rxlosInverted(2),
                          txFault(3),
                          txDisable(4),
                          rateSelect(5),
                          unallocated6(6),
                          unallocated7(7),
                          linearOutput(8),
                          powerLevel(9),
                          cooledTransceiver(10),
                          reserved11(11),
                          reserved12(12),
                          reserved13(13),
                          reserved14(14),
                          reserved15(15)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports options implemented in the transceiver 
            as described in the Options Values table of [SFF 8472]. 
            The following rate identifier types can be reported:
            unallocated: unallocated options value
            
            rxlosNormal: Loss of Signal implemented, behavior as defined in 
            [SFF 8419] (often called Rx_LOS)
            
            rxlosInverted: Loss of Signal implemented, signal inverted from
            standard definition in SFP MSA (often called Signal Detect)
            
            txFault: TX_FAULT signal implemented. Reference  [SFF 8419]        
            txDisable: TX_DISABLE is implemented and disables the high speed serial output.
            rateSelect: RATE_SELECT functionality is implemented.
            unallocated6: unallocated options value
            unallocated7: unallocated options value
            
            powerLevel: Power Level Declaration. Value of zero identifies Power 
            Level 1 (or unspecified) requirements. Value of one identifies Power
            Level 2 requirement. See [SFF 8472] I/O Timing for Soft Control and 
            Status Functions table and Extended Module Control/Status Bytes table 
            for control, status, timing. See [SFF 8472] Option Values table Address
            A0h byte 64, Bit 5 for Power Level 3 declaration. See [SFF 8472] Option 
            Values table Address A0h byte 64, Bit 6 for Power Level 4 declaration.
            Reference  [SFF 8431].
            
            cooledTransceiver: Cooled Transceiver Declaration. Value of zero identifies 
            a conventional uncooled (or unspecified) laser implementation. Value of one
            identifies a cooled laser transmitter implementation. Reference [SFF 8431].
            
            Reference [SFF 8472]"
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 22 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-01-20.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusOptions.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.394938+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-03-31.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusOptions  OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          rxlosNormal(1),
                          rxlosInverted(2),
                          txFault(3),
                          txDisable(4),
                          rateSelect(5),
                          unallocated6(6),
                          unallocated7(7),
                          linearOutput(8),
                          powerLevel(9),
                          cooledTransceiver(10),
                          reserved11(11),
                          reserved12(12),
                          reserved13(13),
                          reserved14(14),
                          reserved15(15)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports options implemented in the transceiver 
            as described in the Options Values table of [SFF 8472]. 
            The following rate identifier types can be reported:
            unallocated: unallocated options value
            
            rxlosNormal: Loss of Signal implemented, behavior as defined in 
            [SFF 8419] (often called Rx_LOS)
            
            rxlosInverted: Loss of Signal implemented, signal inverted from
            standard definition in SFP MSA (often called Signal Detect)
            
            txFault: TX_FAULT signal implemented. Reference  [SFF 8419]        
            txDisable: TX_DISABLE is implemented and disables the high speed serial output.
            rateSelect: RATE_SELECT functionality is implemented.
            unallocated6: unallocated options value
            unallocated7: unallocated options value
            
            powerLevel: Power Level Declaration. Value of zero identifies Power 
            Level 1 (or unspecified) requirements. Value of one identifies Power
            Level 2 requirement. See [SFF 8472] I/O Timing for Soft Control and 
            Status Functions table and Extended Module Control/Status Bytes table 
            for control, status, timing. See [SFF 8472] Option Values table Address
            A0h byte 64, Bit 5 for Power Level 3 declaration. See [SFF 8472] Option 
            Values table Address A0h byte 64, Bit 6 for Power Level 4 declaration.
            Reference  [SFF 8431].
            
            cooledTransceiver: Cooled Transceiver Declaration. Value of zero identifies 
            a conventional uncooled (or unspecified) laser implementation. Value of one
            identifies a cooled laser transmitter implementation. Reference [SFF 8431].
            
            Reference [SFF 8472]"
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 22 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-03-31.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusOptions.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.424309+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-06-30.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusOptions  OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          rxlosNormal(1),
                          rxlosInverted(2),
                          txFault(3),
                          txDisable(4),
                          rateSelect(5),
                          unallocated6(6),
                          unallocated7(7),
                          linearOutput(8),
                          powerLevel(9),
                          cooledTransceiver(10),
                          reserved11(11),
                          reserved12(12),
                          reserved13(13),
                          reserved14(14),
                          reserved15(15)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports options implemented in the transceiver 
            as described in the Options Values table of [SFF 8472]. 
            The following rate identifier types can be reported:
            unallocated: unallocated options value
            
            rxlosNormal: Loss of Signal implemented, behavior as defined in 
            [SFF 8419] (often called Rx_LOS)
            
            rxlosInverted: Loss of Signal implemented, signal inverted from
            standard definition in SFP MSA (often called Signal Detect)
            
            txFault: TX_FAULT signal implemented. Reference  [SFF 8419]        
            txDisable: TX_DISABLE is implemented and disables the high speed serial output.
            rateSelect: RATE_SELECT functionality is implemented.
            unallocated6: unallocated options value
            unallocated7: unallocated options value
            
            powerLevel: Power Level Declaration. Value of zero identifies Power 
            Level 1 (or unspecified) requirements. Value of one identifies Power
            Level 2 requirement. See [SFF 8472] I/O Timing for Soft Control and 
            Status Functions table and Extended Module Control/Status Bytes table 
            for control, status, timing. See [SFF 8472] Option Values table Address
            A0h byte 64, Bit 5 for Power Level 3 declaration. See [SFF 8472] Option 
            Values table Address A0h byte 64, Bit 6 for Power Level 4 declaration.
            Reference  [SFF 8431].
            
            cooledTransceiver: Cooled Transceiver Declaration. Value of zero identifies 
            a conventional uncooled (or unspecified) laser implementation. Value of one
            identifies a cooled laser transmitter implementation. Reference [SFF 8431].
            
            Reference [SFF 8472]"
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 22 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-06-30.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusOptions.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.542970+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-12-01.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusOptions  OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          rxlosNormal(1),
                          rxlosInverted(2),
                          txFault(3),
                          txDisable(4),
                          rateSelect(5),
                          unallocated6(6),
                          unallocated7(7),
                          linearOutput(8),
                          powerLevel(9),
                          cooledTransceiver(10),
                          reserved11(11),
                          reserved12(12),
                          reserved13(13),
                          reserved14(14),
                          reserved15(15)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports options implemented in the transceiver 
            as described in the Options Values table of [SFF 8472]. 
            The following rate identifier types can be reported:
            unallocated: unallocated options value
            
            rxlosNormal: Loss of Signal implemented, behavior as defined in 
            [SFF 8419] (often called Rx_LOS)
            
            rxlosInverted: Loss of Signal implemented, signal inverted from
            standard definition in SFP MSA (often called Signal Detect)
            
            txFault: TX_FAULT signal implemented. Reference  [SFF 8419]        
            txDisable: TX_DISABLE is implemented and disables the high speed serial output.
            rateSelect: RATE_SELECT functionality is implemented.
            unallocated6: unallocated options value
            unallocated7: unallocated options value
            
            powerLevel: Power Level Declaration. Value of zero identifies Power 
            Level 1 (or unspecified) requirements. Value of one identifies Power
            Level 2 requirement. See [SFF 8472] I/O Timing for Soft Control and 
            Status Functions table and Extended Module Control/Status Bytes table 
            for control, status, timing. See [SFF 8472] Option Values table Address
            A0h byte 64, Bit 5 for Power Level 3 declaration. See [SFF 8472] Option 
            Values table Address A0h byte 64, Bit 6 for Power Level 4 declaration.
            Reference  [SFF 8431].
            
            cooledTransceiver: Cooled Transceiver Declaration. Value of zero identifies 
            a conventional uncooled (or unspecified) laser implementation. Value of one
            identifies a cooled laser transmitter implementation. Reference [SFF 8431].
            
            Reference [SFF 8472]"
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 22 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-12-01.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusOptions.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.089920+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2023-10-12.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusOptions  OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          rxlosNormal(1),
                          rxlosInverted(2),
                          txFault(3),
                          txDisable(4),
                          rateSelect(5),
                          unallocated6(6),
                          unallocated7(7),
                          linearOutput(8),
                          powerLevel(9),
                          cooledTransceiver(10),
                          reserved11(11),
                          reserved12(12),
                          reserved13(13),
                          reserved14(14),
                          reserved15(15)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports options implemented in the transceiver 
            as described in the Options Values table of [SFF 8472]. 
            The following rate identifier types can be reported:
            unallocated: unallocated options value
            
            rxlosNormal: Loss of Signal implemented, behavior as defined in 
            [SFF 8419] (often called Rx_LOS)
            
            rxlosInverted: Loss of Signal implemented, signal inverted from
            standard definition in SFP MSA (often called Signal Detect)
            
            txFault: TX_FAULT signal implemented. Reference  [SFF 8419]        
            txDisable: TX_DISABLE is implemented and disables the high speed serial output.
            rateSelect: RATE_SELECT functionality is implemented.
            unallocated6: unallocated options value
            unallocated7: unallocated options value
            
            powerLevel: Power Level Declaration. Value of zero identifies Power 
            Level 1 (or unspecified) requirements. Value of one identifies Power
            Level 2 requirement. See [SFF 8472] I/O Timing for Soft Control and 
            Status Functions table and Extended Module Control/Status Bytes table 
            for control, status, timing. See [SFF 8472] Option Values table Address
            A0h byte 64, Bit 5 for Power Level 3 declaration. See [SFF 8472] Option 
            Values table Address A0h byte 64, Bit 6 for Power Level 4 declaration.
            Reference  [SFF 8431].
            
            cooledTransceiver: Cooled Transceiver Declaration. Value of zero identifies 
            a conventional uncooled (or unspecified) laser implementation. Value of one
            identifies a cooled laser transmitter implementation. Reference [SFF 8431].
            
            Reference [SFF 8472]"
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 22 }
    Module imports
    {'IF-MIB': ['ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['InterfaceIndex', 'TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.

    · Download DOCS-RPHY-MIB-2023-10-12.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusOptions.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.579257+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2024-01-18.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusOptions  OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          rxlosNormal(1),
                          rxlosInverted(2),
                          txFault(3),
                          txDisable(4),
                          rateSelect(5),
                          unallocated6(6),
                          unallocated7(7),
                          linearOutput(8),
                          powerLevel(9),
                          cooledTransceiver(10),
                          reserved11(11),
                          reserved12(12),
                          reserved13(13),
                          reserved14(14),
                          reserved15(15)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports options implemented in the transceiver 
            as described in the Options Values table of [SFF 8472]. 
            The following rate identifier types can be reported:
            unallocated: unallocated options value
            
            rxlosNormal: Loss of Signal implemented, behavior as defined in 
            [SFF 8419] (often called Rx_LOS)
            
            rxlosInverted: Loss of Signal implemented, signal inverted from
            standard definition in SFP MSA (often called Signal Detect)
            
            txFault: TX_FAULT signal implemented. Reference  [SFF 8419]        
            txDisable: TX_DISABLE is implemented and disables the high speed serial output.
            rateSelect: RATE_SELECT functionality is implemented.
            unallocated6: unallocated options value
            unallocated7: unallocated options value
            
            powerLevel: Power Level Declaration. Value of zero identifies Power 
            Level 1 (or unspecified) requirements. Value of one identifies Power
            Level 2 requirement. See [SFF 8472] I/O Timing for Soft Control and 
            Status Functions table and Extended Module Control/Status Bytes table 
            for control, status, timing. See [SFF 8472] Option Values table Address
            A0h byte 64, Bit 5 for Power Level 3 declaration. See [SFF 8472] Option 
            Values table Address A0h byte 64, Bit 6 for Power Level 4 declaration.
            Reference  [SFF 8431].
            
            cooledTransceiver: Cooled Transceiver Declaration. Value of zero identifies 
            a conventional uncooled (or unspecified) laser implementation. Value of one
            identifies a cooled laser transmitter implementation. Reference [SFF 8431].
            
            Reference [SFF 8472]"
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 22 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2024-01-18.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusOptions.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.575041+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2025-01-23.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusOptions  OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          rxlosNormal(1),
                          rxlosInverted(2),
                          txFault(3),
                          txDisable(4),
                          rateSelect(5),
                          unallocated6(6),
                          unallocated7(7),
                          linearOutput(8),
                          powerLevel(9),
                          cooledTransceiver(10),
                          reserved11(11),
                          reserved12(12),
                          reserved13(13),
                          reserved14(14),
                          reserved15(15)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports options implemented in the transceiver 
            as described in the Options Values table of [SFF 8472]. 
            The following rate identifier types can be reported:
            unallocated: unallocated options value
            
            rxlosNormal: Loss of Signal implemented, behavior as defined in 
            [SFF 8419] (often called Rx_LOS)
            
            rxlosInverted: Loss of Signal implemented, signal inverted from
            standard definition in SFP MSA (often called Signal Detect)
            
            txFault: TX_FAULT signal implemented. Reference  [SFF 8419]        
            txDisable: TX_DISABLE is implemented and disables the high speed serial output.
            rateSelect: RATE_SELECT functionality is implemented.
            unallocated6: unallocated options value
            unallocated7: unallocated options value
            
            powerLevel: Power Level Declaration. Value of zero identifies Power 
            Level 1 (or unspecified) requirements. Value of one identifies Power
            Level 2 requirement. See [SFF 8472] I/O Timing for Soft Control and 
            Status Functions table and Extended Module Control/Status Bytes table 
            for control, status, timing. See [SFF 8472] Option Values table Address
            A0h byte 64, Bit 5 for Power Level 3 declaration. See [SFF 8472] Option 
            Values table Address A0h byte 64, Bit 6 for Power Level 4 declaration.
            Reference  [SFF 8431].
            
            cooledTransceiver: Cooled Transceiver Declaration. Value of zero identifies 
            a conventional uncooled (or unspecified) laser implementation. Value of one
            identifies a cooled laser transmitter implementation. Reference [SFF 8431].
            
            Reference [SFF 8472]"
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 22 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2025-01-23.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusOptions.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.705674+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB.mib

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusOptions  OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          rxlosNormal(1),
                          rxlosInverted(2),
                          txFault(3),
                          txDisable(4),
                          rateSelect(5),
                          unallocated6(6),
                          unallocated7(7),
                          linearOutput(8),
                          powerLevel(9),
                          cooledTransceiver(10),
                          reserved11(11),
                          reserved12(12),
                          reserved13(13),
                          reserved14(14),
                          reserved15(15)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports options implemented in the transceiver 
            as described in the Options Values table of [SFF 8472]. 
            The following rate identifier types can be reported:
            unallocated: unallocated options value
            
            rxlosNormal: Loss of Signal implemented, behavior as defined in 
            [SFF 8419] (often called Rx_LOS)
            
            rxlosInverted: Loss of Signal implemented, signal inverted from
            standard definition in SFP MSA (often called Signal Detect)
            
            txFault: TX_FAULT signal implemented. Reference  [SFF 8419]        
            txDisable: TX_DISABLE is implemented and disables the high speed serial output.
            rateSelect: RATE_SELECT functionality is implemented.
            unallocated6: unallocated options value
            unallocated7: unallocated options value
            
            powerLevel: Power Level Declaration. Value of zero identifies Power 
            Level 1 (or unspecified) requirements. Value of one identifies Power
            Level 2 requirement. See [SFF 8472] I/O Timing for Soft Control and 
            Status Functions table and Extended Module Control/Status Bytes table 
            for control, status, timing. See [SFF 8472] Option Values table Address
            A0h byte 64, Bit 5 for Power Level 3 declaration. See [SFF 8472] Option 
            Values table Address A0h byte 64, Bit 6 for Power Level 4 declaration.
            Reference  [SFF 8431].
            
            cooledTransceiver: Cooled Transceiver Declaration. Value of zero identifies 
            a conventional uncooled (or unspecified) laser implementation. Value of one
            identifies a cooled laser transmitter implementation. Reference [SFF 8431].
            
            Reference [SFF 8472]"
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 22 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB.mib
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusOptions.
    Source version and references

    Downloaded: 2026-10-26T22:47:25.372984+00:00.

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Ralph Brown

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Maria Stachelek

Siblings (35)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.1 docsRphyRpdIfEnetSfpPlusStatusStatus00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.2 docsRphyRpdIfEnetSfpPlusStatusIdentifier00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.3 docsRphyRpdIfEnetSfpPlusStatusExtendedIdentifier00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.4 docsRphyRpdIfEnetSfpPlusStatusConnectorType00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.5 docsRphyRpdIfEnetSfpPlusStatusTransceiverComplianceCodes00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.6 docsRphyRpdIfEnetSfpPlusStatusTransceiverComplianceCode3600
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.7 docsRphyRpdIfEnetSfpPlusStatusEncoding00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.8 docsRphyRpdIfEnetSfpPlusStatusBitRateNominal00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.9 docsRphyRpdIfEnetSfpPlusStatusRateIdentifier00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.10 docsRphyRpdIfEnetSfpPlusStatusLengthKm00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.11 docsRphyRpdIfEnetSfpPlusStatusLength100M00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.12 docsRphyRpdIfEnetSfpPlusStatusLength50Mi10M00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.13 docsRphyRpdIfEnetSfpPlusStatusLength62Pt5Mi10M00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.14 docsRphyRpdIfEnetSfpPlusStatusLengthCopperM00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.15 docsRphyRpdIfEnetSfpPlusStatusLength50MiOm300
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.16 docsRphyRpdIfEnetSfpPlusStatusVendorName00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.17 docsRphyRpdIfEnetSfpPlusStatusVendorOui00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.18 docsRphyRpdIfEnetSfpPlusStatusVendorPartNum00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.19 docsRphyRpdIfEnetSfpPlusStatusVendorSerialNum00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.20 docsRphyRpdIfEnetSfpPlusStatusVendorRev00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.21 docsRphyRpdIfEnetSfpPlusStatusLaserWavelength00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.23 docsRphyRpdIfEnetSfpPlusStatusBitRateMax00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.24 docsRphyRpdIfEnetSfpPlusStatusBitRateMin00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.25 docsRphyRpdIfEnetSfpPlusStatusVendorDate00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.26 docsRphyRpdIfEnetSfpPlusStatusVendorSpecificLotCode00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.27 docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.28 docsRphyRpdIfEnetSfpPlusStatusEnhancedOptions00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.29 docsRphyRpdIfEnetSfpPlusStatusSff8472Compliance00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.30 docsRphyRpdIfEnetSfpPlusStatusVendorSpecificData00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.31 docsRphyRpdIfEnetSfpPlusStatusMeasuredTxOutputPwr00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.32 docsRphyRpdIfEnetSfpPlusStatusMeasuredRxInputPwr00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.33 docsRphyRpdIfEnetSfpPlusStatusDigitalDiagA2Info00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.34 docsRphyRpdIfEnetSfpPlusStatusMeasuredTxBiasCurrent00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.35 docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.36 docsRphyRpdIfEnetSfpPlusStatusMeasuredSupplyVoltage00