Reference record for OID 1.3.6.1.4.1.4491.2.1.30.1.2.8.1.27

Parent
1.3.6.1.4.1.4491.2.1.30.1.2.8.1 (docsRphyRpdIfEnetSfpPlusStatusEntry)
Node code
27
Node name
docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType
Numeric OID
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.27
URN notation
urn:oid:1.3.6.1.4.1.4491.2.1.30.1.2.8.1.27
ASN.1 notation

{1 3 6 1 4 1 4491 2 1 30 1 2 8 1 27}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType(27)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/4491/2/1/30/1/2/8/1/27
  • /ISO/Identified-Organization/6/1/4/1/4491/2/1/30/1/2/8/1/27
  • /ISO/3/6/1/4/1/4491/2/1/30/1/2/8/1/27
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType
  • Additional combinations skipped.

Descriptions

docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType — CableLabs official current and historical MIBs

This attribute reports how diagnostic monitoring is implemented in the selected transceiver.

docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType — CableLabs official current and historical MIBs

This attribute reports how diagnostic monitoring is implemented in the selected transceiver. The following diagnostic monitoring types can be reported: unallocated: unallocated diagnostic monitoring type unallocated1: unallocated diagnostic monitoring type addrChangeReq: Address change required recPwrMeasType: Received power measurement type. 0 = OMA, 1 = average power. externCalibrated: externally calibrated internCalibrated: internally calibrated digDiagImpl: digital diagnostic monitoring implemented legacyImpl: Reserved for legacy diagnostic implementations. Must be '0' for compliance with [SFF 8472]. Reference [SFF 8472]

docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType — CableLabs official current and historical MIBs

This attribute reports how diagnostic monitoring is implemented in the selected transceiver. Note: The encoding of bit values of this attribute reflects the inverse bit numbering convention of the SFF specification.

Source records

docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType

Status in source: current.

Names: docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType",
    "OBJECT-TYPE",
    "SYNTAX",
    "BITS",
    "{",
    "unallocated0",
    "(",
    "0",
    ")",
    ",",
    "unallocated1",
    "(",
    "1",
    ")",
    ",",
    "addrChangeReq",
    "(",
    "2",
    ")",
    ",",
    "recPwrMeasType",
    "(",
    "3",
    ")",
    ",",
    "externCalibrated",
    "(",
    "4",
    ")",
    ",",
    "internCalibrated",
    "(",
    "5",
    ")",
    ",",
    "digDiagImpl",
    "(",
    "6",
    ")",
    ",",
    "legacyImpl",
    "(",
    "7",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This attribute reports how diagnostic monitoring is implemented in the selected transceiver.\"",
    "::=",
    "{",
    "docsRphyRpdIfEnetSfpPlusStatusEntry",
    "27",
    "}"
  ],
  "syntax_tree": [
    [
      "BITS",
      [
        [
          "unallocated0",
          0
        ],
        [
          "unallocated1",
          1
        ],
        [
          "addrChangeReq",
          2
        ],
        [
          "recPwrMeasType",
          3
        ],
        [
          "externCalibrated",
          4
        ],
        [
          "internCalibrated",
          5
        ],
        [
          "digDiagImpl",
          6
        ],
        [
          "legacyImpl",
          7
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This attribute reports how diagnostic monitoring is implemented in the selected transceiver."
    ],
    null,
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2019-01-24.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType	OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
    		      unallocated1(1),
    		      addrChangeReq(2),
    		      recPwrMeasType(3),
    		      externCalibrated(4),
    		      internCalibrated(5),
    		      digDiagImpl(6),
    		      legacyImpl(7)
                     }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
                "This attribute reports how diagnostic monitoring
                 is implemented in the selected transceiver."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 27 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex', 'InterfaceIndexOrZero'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'AutonomousType', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'DOCS-IETF-BPI2-MIB': ['DocsX509ASN1DEREncodedCertificate'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2019-01-24.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.074775+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2019-06-13.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType    OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          unallocated1(1),
                          addrChangeReq(2),
                          recPwrMeasType(3),
                          externCalibrated(4),
                          internCalibrated(5),
                          digDiagImpl(6),
                          legacyImpl(7)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports how diagnostic monitoring
             is implemented in the selected transceiver."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 27 }
    Module imports
    {'IF-MIB': ['InterfaceIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2019-06-13.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.180890+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2019-09-26.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType    OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          unallocated1(1),
                          addrChangeReq(2),
                          recPwrMeasType(3),
                          externCalibrated(4),
                          internCalibrated(5),
                          digDiagImpl(6),
                          legacyImpl(7)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports how diagnostic monitoring
             is implemented in the selected transceiver."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 27 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2019-09-26.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.289076+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2020-01-09.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType    OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          unallocated1(1),
                          addrChangeReq(2),
                          recPwrMeasType(3),
                          externCalibrated(4),
                          internCalibrated(5),
                          digDiagImpl(6),
                          legacyImpl(7)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports how diagnostic monitoring
             is implemented in the selected transceiver."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 27 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2020-01-09.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.938082+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2020-10-01.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType    OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          unallocated1(1),
                          addrChangeReq(2),
                          recPwrMeasType(3),
                          externCalibrated(4),
                          internCalibrated(5),
                          digDiagImpl(6),
                          legacyImpl(7)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports how diagnostic monitoring
             is implemented in the selected transceiver."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 27 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2020-10-01.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:56.354948+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2021-03-11.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType    OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          unallocated1(1),
                          addrChangeReq(2),
                          recPwrMeasType(3),
                          externCalibrated(4),
                          internCalibrated(5),
                          digDiagImpl(6),
                          legacyImpl(7)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports how diagnostic monitoring
             is implemented in the selected transceiver."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 27 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2021-03-11.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:56.429401+00:00.

docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType

Status in source: current.

Names: docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType",
    "OBJECT-TYPE",
    "SYNTAX",
    "BITS",
    "{",
    "unallocated0",
    "(",
    "0",
    ")",
    ",",
    "unallocated1",
    "(",
    "1",
    ")",
    ",",
    "addrChangeReq",
    "(",
    "2",
    ")",
    ",",
    "recPwrMeasType",
    "(",
    "3",
    ")",
    ",",
    "externCalibrated",
    "(",
    "4",
    ")",
    ",",
    "internCalibrated",
    "(",
    "5",
    ")",
    ",",
    "digDiagImpl",
    "(",
    "6",
    ")",
    ",",
    "legacyImpl",
    "(",
    "7",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This attribute reports how diagnostic monitoring is implemented in the selected transceiver. The following diagnostic monitoring types can be reported: unallocated: unallocated diagnostic monitoring type unallocated1: unallocated diagnostic monitoring type addrChangeReq: Address change required recPwrMeasType: Received power measurement type. 0 = OMA, 1 = average power. externCalibrated: externally calibrated internCalibrated: internally calibrated digDiagImpl: digital diagnostic monitoring implemented legacyImpl: Reserved for legacy diagnostic implementations. Must be '0' for compliance with [SFF 8472]. Reference [SFF 8472]\"",
    "::=",
    "{",
    "docsRphyRpdIfEnetSfpPlusStatusEntry",
    "27",
    "}"
  ],
  "syntax_tree": [
    [
      "BITS",
      [
        [
          "unallocated0",
          0
        ],
        [
          "unallocated1",
          1
        ],
        [
          "addrChangeReq",
          2
        ],
        [
          "recPwrMeasType",
          3
        ],
        [
          "externCalibrated",
          4
        ],
        [
          "internCalibrated",
          5
        ],
        [
          "digDiagImpl",
          6
        ],
        [
          "legacyImpl",
          7
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This attribute reports how diagnostic monitoring is implemented in the selected transceiver. The following diagnostic monitoring types can be reported: unallocated: unallocated diagnostic monitoring type unallocated1: unallocated diagnostic monitoring type addrChangeReq: Address change required recPwrMeasType: Received power measurement type. 0 = OMA, 1 = average power. externCalibrated: externally calibrated internCalibrated: internally calibrated digDiagImpl: digital diagnostic monitoring implemented legacyImpl: Reserved for legacy diagnostic implementations. Must be '0' for compliance with [SFF 8472]. Reference [SFF 8472]"
    ],
    null,
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2021-10-21.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType    OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          unallocated1(1),
                          addrChangeReq(2),
                          recPwrMeasType(3),
                          externCalibrated(4),
                          internCalibrated(5),
                          digDiagImpl(6),
                          legacyImpl(7)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports how diagnostic monitoring
             is implemented in the selected transceiver.
             The following diagnostic monitoring types can be reported:
             unallocated: unallocated diagnostic monitoring type
             unallocated1: unallocated diagnostic monitoring type
             addrChangeReq: Address change required
             recPwrMeasType: Received power measurement type. 0 = OMA, 1 = average power.
             externCalibrated: externally calibrated
             internCalibrated: internally calibrated
             digDiagImpl: digital diagnostic monitoring implemented
             legacyImpl: Reserved for legacy diagnostic implementations. 
             Must be '0' for compliance with [SFF 8472].
             Reference [SFF 8472]"
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 27 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2021-10-21.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.003028+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-01-20.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType    OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          unallocated1(1),
                          addrChangeReq(2),
                          recPwrMeasType(3),
                          externCalibrated(4),
                          internCalibrated(5),
                          digDiagImpl(6),
                          legacyImpl(7)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports how diagnostic monitoring
             is implemented in the selected transceiver.
             The following diagnostic monitoring types can be reported:
             unallocated: unallocated diagnostic monitoring type
             unallocated1: unallocated diagnostic monitoring type
             addrChangeReq: Address change required
             recPwrMeasType: Received power measurement type. 0 = OMA, 1 = average power.
             externCalibrated: externally calibrated
             internCalibrated: internally calibrated
             digDiagImpl: digital diagnostic monitoring implemented
             legacyImpl: Reserved for legacy diagnostic implementations. 
             Must be '0' for compliance with [SFF 8472].
             Reference [SFF 8472]"
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 27 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-01-20.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.394938+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-03-31.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType    OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          unallocated1(1),
                          addrChangeReq(2),
                          recPwrMeasType(3),
                          externCalibrated(4),
                          internCalibrated(5),
                          digDiagImpl(6),
                          legacyImpl(7)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports how diagnostic monitoring
             is implemented in the selected transceiver.
             The following diagnostic monitoring types can be reported:
             unallocated: unallocated diagnostic monitoring type
             unallocated1: unallocated diagnostic monitoring type
             addrChangeReq: Address change required
             recPwrMeasType: Received power measurement type. 0 = OMA, 1 = average power.
             externCalibrated: externally calibrated
             internCalibrated: internally calibrated
             digDiagImpl: digital diagnostic monitoring implemented
             legacyImpl: Reserved for legacy diagnostic implementations. 
             Must be '0' for compliance with [SFF 8472].
             Reference [SFF 8472]"
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 27 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-03-31.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.424309+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-06-30.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType    OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          unallocated1(1),
                          addrChangeReq(2),
                          recPwrMeasType(3),
                          externCalibrated(4),
                          internCalibrated(5),
                          digDiagImpl(6),
                          legacyImpl(7)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports how diagnostic monitoring
             is implemented in the selected transceiver.
             The following diagnostic monitoring types can be reported:
             unallocated: unallocated diagnostic monitoring type
             unallocated1: unallocated diagnostic monitoring type
             addrChangeReq: Address change required
             recPwrMeasType: Received power measurement type. 0 = OMA, 1 = average power.
             externCalibrated: externally calibrated
             internCalibrated: internally calibrated
             digDiagImpl: digital diagnostic monitoring implemented
             legacyImpl: Reserved for legacy diagnostic implementations. 
             Must be '0' for compliance with [SFF 8472].
             Reference [SFF 8472]"
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 27 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-06-30.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.542970+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-12-01.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType    OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          unallocated1(1),
                          addrChangeReq(2),
                          recPwrMeasType(3),
                          externCalibrated(4),
                          internCalibrated(5),
                          digDiagImpl(6),
                          legacyImpl(7)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports how diagnostic monitoring
             is implemented in the selected transceiver.
             The following diagnostic monitoring types can be reported:
             unallocated: unallocated diagnostic monitoring type
             unallocated1: unallocated diagnostic monitoring type
             addrChangeReq: Address change required
             recPwrMeasType: Received power measurement type. 0 = OMA, 1 = average power.
             externCalibrated: externally calibrated
             internCalibrated: internally calibrated
             digDiagImpl: digital diagnostic monitoring implemented
             legacyImpl: Reserved for legacy diagnostic implementations. 
             Must be '0' for compliance with [SFF 8472].
             Reference [SFF 8472]"
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 27 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-12-01.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.089920+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2023-10-12.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType    OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          unallocated1(1),
                          addrChangeReq(2),
                          recPwrMeasType(3),
                          externCalibrated(4),
                          internCalibrated(5),
                          digDiagImpl(6),
                          legacyImpl(7)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports how diagnostic monitoring
             is implemented in the selected transceiver.
             The following diagnostic monitoring types can be reported:
             unallocated: unallocated diagnostic monitoring type
             unallocated1: unallocated diagnostic monitoring type
             addrChangeReq: Address change required
             recPwrMeasType: Received power measurement type. 0 = OMA, 1 = average power.
             externCalibrated: externally calibrated
             internCalibrated: internally calibrated
             digDiagImpl: digital diagnostic monitoring implemented
             legacyImpl: Reserved for legacy diagnostic implementations. 
             Must be '0' for compliance with [SFF 8472].
             Reference [SFF 8472]"
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 27 }
    Module imports
    {'IF-MIB': ['ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['InterfaceIndex', 'TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.

    · Download DOCS-RPHY-MIB-2023-10-12.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.579257+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2024-01-18.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType    OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          unallocated1(1),
                          addrChangeReq(2),
                          recPwrMeasType(3),
                          externCalibrated(4),
                          internCalibrated(5),
                          digDiagImpl(6),
                          legacyImpl(7)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports how diagnostic monitoring
             is implemented in the selected transceiver.
             The following diagnostic monitoring types can be reported:
             unallocated: unallocated diagnostic monitoring type
             unallocated1: unallocated diagnostic monitoring type
             addrChangeReq: Address change required
             recPwrMeasType: Received power measurement type. 0 = OMA, 1 = average power.
             externCalibrated: externally calibrated
             internCalibrated: internally calibrated
             digDiagImpl: digital diagnostic monitoring implemented
             legacyImpl: Reserved for legacy diagnostic implementations. 
             Must be '0' for compliance with [SFF 8472].
             Reference [SFF 8472]"
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 27 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2024-01-18.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.575041+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2025-01-23.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType    OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          unallocated1(1),
                          addrChangeReq(2),
                          recPwrMeasType(3),
                          externCalibrated(4),
                          internCalibrated(5),
                          digDiagImpl(6),
                          legacyImpl(7)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports how diagnostic monitoring
             is implemented in the selected transceiver.
             The following diagnostic monitoring types can be reported:
             unallocated: unallocated diagnostic monitoring type
             unallocated1: unallocated diagnostic monitoring type
             addrChangeReq: Address change required
             recPwrMeasType: Received power measurement type. 0 = OMA, 1 = average power.
             externCalibrated: externally calibrated
             internCalibrated: internally calibrated
             digDiagImpl: digital diagnostic monitoring implemented
             legacyImpl: Reserved for legacy diagnostic implementations. 
             Must be '0' for compliance with [SFF 8472].
             Reference [SFF 8472]"
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 27 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2025-01-23.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.705674+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB.mib

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType    OBJECT-TYPE
        SYNTAX      BITS {
                          unallocated0(0),
                          unallocated1(1),
                          addrChangeReq(2),
                          recPwrMeasType(3),
                          externCalibrated(4),
                          internCalibrated(5),
                          digDiagImpl(6),
                          legacyImpl(7)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports how diagnostic monitoring
             is implemented in the selected transceiver.
             The following diagnostic monitoring types can be reported:
             unallocated: unallocated diagnostic monitoring type
             unallocated1: unallocated diagnostic monitoring type
             addrChangeReq: Address change required
             recPwrMeasType: Received power measurement type. 0 = OMA, 1 = average power.
             externCalibrated: externally calibrated
             internCalibrated: internally calibrated
             digDiagImpl: digital diagnostic monitoring implemented
             legacyImpl: Reserved for legacy diagnostic implementations. 
             Must be '0' for compliance with [SFF 8472].
             Reference [SFF 8472]"
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 27 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB.mib
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType.
    Source version and references

    Downloaded: 2026-10-26T22:47:25.372984+00:00.

docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType

Status in source: current.

Names: docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType",
    "OBJECT-TYPE",
    "SYNTAX",
    "BITS",
    "{",
    "legacyImpl",
    "(",
    "0",
    ")",
    ",",
    "digDiagImpl",
    "(",
    "1",
    ")",
    ",",
    "internCalibrated",
    "(",
    "2",
    ")",
    ",",
    "externCalibrated",
    "(",
    "3",
    ")",
    ",",
    "recPwrMeasType",
    "(",
    "4",
    ")",
    ",",
    "addrChangeReq",
    "(",
    "5",
    ")",
    ",",
    "unallocated1",
    "(",
    "6",
    ")",
    ",",
    "unallocated0",
    "(",
    "7",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This attribute reports how diagnostic monitoring is implemented in the selected transceiver. Note: The encoding of bit values of this attribute reflects the inverse bit numbering convention of the SFF specification.\"",
    "::=",
    "{",
    "docsRphyRpdIfEnetSfpPlusStatusEntry",
    "27",
    "}"
  ],
  "syntax_tree": [
    [
      "BITS",
      [
        [
          "legacyImpl",
          0
        ],
        [
          "digDiagImpl",
          1
        ],
        [
          "internCalibrated",
          2
        ],
        [
          "externCalibrated",
          3
        ],
        [
          "recPwrMeasType",
          4
        ],
        [
          "addrChangeReq",
          5
        ],
        [
          "unallocated1",
          6
        ],
        [
          "unallocated0",
          7
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This attribute reports how diagnostic monitoring is implemented in the selected transceiver. Note: The encoding of bit values of this attribute reflects the inverse bit numbering convention of the SFF specification."
    ],
    null,
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2020-05-21.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType    OBJECT-TYPE
        SYNTAX      BITS {
                          legacyImpl(0),
                          digDiagImpl(1),
                          internCalibrated(2),
                          externCalibrated(3),
                          recPwrMeasType(4),
                          addrChangeReq(5),
                          unallocated1(6),
                          unallocated0(7)
                         }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute reports how diagnostic monitoring
             is implemented in the selected transceiver.
             Note: The encoding of bit values of this attribute 
             reflects the inverse bit numbering convention
             of the SFF specification."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 27 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2020-05-21.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType.
    Source version and references

    Downloaded: 2026-10-26T22:49:56.205690+00:00.

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Ralph Brown

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Maria Stachelek

Siblings (35)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.1 docsRphyRpdIfEnetSfpPlusStatusStatus00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.2 docsRphyRpdIfEnetSfpPlusStatusIdentifier00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.3 docsRphyRpdIfEnetSfpPlusStatusExtendedIdentifier00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.4 docsRphyRpdIfEnetSfpPlusStatusConnectorType00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.5 docsRphyRpdIfEnetSfpPlusStatusTransceiverComplianceCodes00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.6 docsRphyRpdIfEnetSfpPlusStatusTransceiverComplianceCode3600
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.7 docsRphyRpdIfEnetSfpPlusStatusEncoding00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.8 docsRphyRpdIfEnetSfpPlusStatusBitRateNominal00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.9 docsRphyRpdIfEnetSfpPlusStatusRateIdentifier00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.10 docsRphyRpdIfEnetSfpPlusStatusLengthKm00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.11 docsRphyRpdIfEnetSfpPlusStatusLength100M00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.12 docsRphyRpdIfEnetSfpPlusStatusLength50Mi10M00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.13 docsRphyRpdIfEnetSfpPlusStatusLength62Pt5Mi10M00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.14 docsRphyRpdIfEnetSfpPlusStatusLengthCopperM00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.15 docsRphyRpdIfEnetSfpPlusStatusLength50MiOm300
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.16 docsRphyRpdIfEnetSfpPlusStatusVendorName00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.17 docsRphyRpdIfEnetSfpPlusStatusVendorOui00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.18 docsRphyRpdIfEnetSfpPlusStatusVendorPartNum00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.19 docsRphyRpdIfEnetSfpPlusStatusVendorSerialNum00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.20 docsRphyRpdIfEnetSfpPlusStatusVendorRev00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.21 docsRphyRpdIfEnetSfpPlusStatusLaserWavelength00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.22 docsRphyRpdIfEnetSfpPlusStatusOptions00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.23 docsRphyRpdIfEnetSfpPlusStatusBitRateMax00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.24 docsRphyRpdIfEnetSfpPlusStatusBitRateMin00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.25 docsRphyRpdIfEnetSfpPlusStatusVendorDate00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.26 docsRphyRpdIfEnetSfpPlusStatusVendorSpecificLotCode00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.28 docsRphyRpdIfEnetSfpPlusStatusEnhancedOptions00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.29 docsRphyRpdIfEnetSfpPlusStatusSff8472Compliance00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.30 docsRphyRpdIfEnetSfpPlusStatusVendorSpecificData00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.31 docsRphyRpdIfEnetSfpPlusStatusMeasuredTxOutputPwr00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.32 docsRphyRpdIfEnetSfpPlusStatusMeasuredRxInputPwr00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.33 docsRphyRpdIfEnetSfpPlusStatusDigitalDiagA2Info00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.34 docsRphyRpdIfEnetSfpPlusStatusMeasuredTxBiasCurrent00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.35 docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.36 docsRphyRpdIfEnetSfpPlusStatusMeasuredSupplyVoltage00