Reference record for OID 1.3.6.1.4.1.4491.2.1.30.1.2.8.1.35

Parent
1.3.6.1.4.1.4491.2.1.30.1.2.8.1 (docsRphyRpdIfEnetSfpPlusStatusEntry)
Node code
35
Node name
docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature
Numeric OID
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.35
URN notation
urn:oid:1.3.6.1.4.1.4491.2.1.30.1.2.8.1.35
ASN.1 notation

{1 3 6 1 4 1 4491 2 1 30 1 2 8 1 35}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature(35)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature(35)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature(35)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature(35)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature(35)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature(35)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature(35)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature(35)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature(35)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature(35)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature(35)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cableLabs(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature(35)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature(35)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyMibObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature(35)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdPhysMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature(35)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cable-Television-Laboratories-Inc(4491) clabProject(2) clabProjDocsis(1) docsRphyMib(30) docsRphyObjects(1) docsRphyRpdIfMibObjects(2) docsRphyRpdIfEnetSfpPlusStatusTable(8) docsRphyRpdIfEnetSfpPlusStatusEntry(1) docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature(35)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/4491/2/1/30/1/2/8/1/35
  • /ISO/Identified-Organization/6/1/4/1/4491/2/1/30/1/2/8/1/35
  • /ISO/3/6/1/4/1/4491/2/1/30/1/2/8/1/35
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature
  • /iso/identified-organization/dod/internet/private/enterprise/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature
  • /iso/identified-organization/dod/internet/private/enterprise/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature
  • /iso/identified-organization/dod/internet/private/enterprises/cableLabs/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyMibObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdPhysMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature
  • /iso/identified-organization/dod/internet/private/enterprises/cable-Television-Laboratories-Inc/clabProject/clabProjDocsis/docsRphyMib/docsRphyObjects/docsRphyRpdIfMibObjects/docsRphyRpdIfEnetSfpPlusStatusTable/docsRphyRpdIfEnetSfpPlusStatusEntry/docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature
  • Additional combinations skipped.

Descriptions

docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature — CableLabs official current and historical MIBs

This attribute, which is optional for SFP+ pluggable transceivers, reports internally measured transceiver temperature as a signed twos compliment value in increments of 1/256 degrees Celsius. If this attribute is not supported by the RPD's transceivers, the RPD will return a value of zero.

Source records

docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature

Status in source: current.

Names: docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "32768",
    ".",
    ".",
    "32767",
    ")",
    "UNITS",
    [
      "literal",
      "22312f323536206465677265652063656c7369757322"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This attribute, which is optional for SFP+ pluggable transceivers, reports internally measured transceiver temperature as a signed twos compliment value in increments of 1/256 degrees Celsius. If this attribute is not supported by the RPD's transceivers, the RPD will return a value of zero.\"",
    "::=",
    "{",
    "docsRphyRpdIfEnetSfpPlusStatusEntry",
    "35",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -32768,
            32767
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "1/256 degree celsius"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This attribute, which is optional for SFP+ pluggable transceivers, reports internally measured transceiver temperature as a signed twos compliment value in increments of 1/256 degrees Celsius. If this attribute is not supported by the RPD's transceivers, the RPD will return a value of zero."
    ],
    null,
    null,
    null,
    null
  ]
}
  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2019-09-26.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature OBJECT-TYPE
        SYNTAX      Integer32 (-32768..32767)
        UNITS       "1/256 degree celsius"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute, which is optional for SFP+ pluggable transceivers,
             reports internally measured transceiver temperature as a signed 
             twos compliment value in increments of 1/256 degrees Celsius. 
             If this attribute is not supported by the RPD's transceivers,
             the RPD will return a value of zero."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 35 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2019-09-26.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.289076+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2020-01-09.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature OBJECT-TYPE
        SYNTAX      Integer32 (-32768..32767)
        UNITS       "1/256 degree celsius"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute, which is optional for SFP+ pluggable transceivers,
             reports internally measured transceiver temperature as a signed 
             twos compliment value in increments of 1/256 degrees Celsius. 
             If this attribute is not supported by the RPD's transceivers,
             the RPD will return a value of zero."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 35 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2020-01-09.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature.
    Source version and references

    Downloaded: 2026-10-26T22:49:55.938082+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2020-05-21.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature OBJECT-TYPE
        SYNTAX      Integer32 (-32768..32767)
        UNITS       "1/256 degree celsius"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute, which is optional for SFP+ pluggable transceivers,
             reports internally measured transceiver temperature as a signed 
             twos compliment value in increments of 1/256 degrees Celsius. 
             If this attribute is not supported by the RPD's transceivers,
             the RPD will return a value of zero."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 35 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2020-05-21.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature.
    Source version and references

    Downloaded: 2026-10-26T22:49:56.205690+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2020-10-01.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature OBJECT-TYPE
        SYNTAX      Integer32 (-32768..32767)
        UNITS       "1/256 degree celsius"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute, which is optional for SFP+ pluggable transceivers,
             reports internally measured transceiver temperature as a signed 
             twos compliment value in increments of 1/256 degrees Celsius. 
             If this attribute is not supported by the RPD's transceivers,
             the RPD will return a value of zero."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 35 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2020-10-01.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature.
    Source version and references

    Downloaded: 2026-10-26T22:49:56.354948+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2021-03-11.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature OBJECT-TYPE
        SYNTAX      Integer32 (-32768..32767)
        UNITS       "1/256 degree celsius"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute, which is optional for SFP+ pluggable transceivers,
             reports internally measured transceiver temperature as a signed 
             twos compliment value in increments of 1/256 degrees Celsius. 
             If this attribute is not supported by the RPD's transceivers,
             the RPD will return a value of zero."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 35 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2021-03-11.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature.
    Source version and references

    Downloaded: 2026-10-26T22:49:56.429401+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2021-10-21.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature OBJECT-TYPE
        SYNTAX      Integer32 (-32768..32767)
        UNITS       "1/256 degree celsius"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute, which is optional for SFP+ pluggable transceivers,
             reports internally measured transceiver temperature as a signed 
             twos compliment value in increments of 1/256 degrees Celsius. 
             If this attribute is not supported by the RPD's transceivers,
             the RPD will return a value of zero."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 35 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2021-10-21.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.003028+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-01-20.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature OBJECT-TYPE
        SYNTAX      Integer32 (-32768..32767)
        UNITS       "1/256 degree celsius"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute, which is optional for SFP+ pluggable transceivers,
             reports internally measured transceiver temperature as a signed 
             twos compliment value in increments of 1/256 degrees Celsius. 
             If this attribute is not supported by the RPD's transceivers,
             the RPD will return a value of zero."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 35 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-01-20.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.394938+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-03-31.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature OBJECT-TYPE
        SYNTAX      Integer32 (-32768..32767)
        UNITS       "1/256 degree celsius"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute, which is optional for SFP+ pluggable transceivers,
             reports internally measured transceiver temperature as a signed 
             twos compliment value in increments of 1/256 degrees Celsius. 
             If this attribute is not supported by the RPD's transceivers,
             the RPD will return a value of zero."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 35 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-03-31.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.424309+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-06-30.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature OBJECT-TYPE
        SYNTAX      Integer32 (-32768..32767)
        UNITS       "1/256 degree celsius"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute, which is optional for SFP+ pluggable transceivers,
             reports internally measured transceiver temperature as a signed 
             twos compliment value in increments of 1/256 degrees Celsius. 
             If this attribute is not supported by the RPD's transceivers,
             the RPD will return a value of zero."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 35 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-06-30.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature.
    Source version and references

    Downloaded: 2026-10-26T22:49:57.542970+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2022-12-01.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature OBJECT-TYPE
        SYNTAX      Integer32 (-32768..32767)
        UNITS       "1/256 degree celsius"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute, which is optional for SFP+ pluggable transceivers,
             reports internally measured transceiver temperature as a signed 
             twos compliment value in increments of 1/256 degrees Celsius. 
             If this attribute is not supported by the RPD's transceivers,
             the RPD will return a value of zero."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 35 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2022-12-01.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.089920+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2023-10-12.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature OBJECT-TYPE
        SYNTAX      Integer32 (-32768..32767)
        UNITS       "1/256 degree celsius"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute, which is optional for SFP+ pluggable transceivers,
             reports internally measured transceiver temperature as a signed 
             twos compliment value in increments of 1/256 degrees Celsius. 
             If this attribute is not supported by the RPD's transceivers,
             the RPD will return a value of zero."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 35 }
    Module imports
    {'IF-MIB': ['ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['InterfaceIndex', 'TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.

    · Download DOCS-RPHY-MIB-2023-10-12.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.579257+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2024-01-18.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature OBJECT-TYPE
        SYNTAX      Integer32 (-32768..32767)
        UNITS       "1/256 degree celsius"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute, which is optional for SFP+ pluggable transceivers,
             reports internally measured transceiver temperature as a signed 
             twos compliment value in increments of 1/256 degrees Celsius. 
             If this attribute is not supported by the RPD's transceivers,
             the RPD will return a value of zero."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 35 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2024-01-18.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.575041+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB-2025-01-23.txt

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature OBJECT-TYPE
        SYNTAX      Integer32 (-32768..32767)
        UNITS       "1/256 degree celsius"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute, which is optional for SFP+ pluggable transceivers,
             reports internally measured transceiver temperature as a signed 
             twos compliment value in increments of 1/256 degrees Celsius. 
             If this attribute is not supported by the RPD's transceivers,
             the RPD will return a value of zero."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 35 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB-2025-01-23.txt
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature.
    Source version and references

    Downloaded: 2026-10-26T22:49:58.705674+00:00.

  • CableLabs official current and historical MIBs · Publisher's source file: DOCS-RPHY-MIB.mib

    Module: DOCS-RPHY-MIB

    Published definition
    docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature OBJECT-TYPE
        SYNTAX      Integer32 (-32768..32767)
        UNITS       "1/256 degree celsius"
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This attribute, which is optional for SFP+ pluggable transceivers,
             reports internally measured transceiver temperature as a signed 
             twos compliment value in increments of 1/256 degrees Celsius. 
             If this attribute is not supported by the RPD's transceivers,
             the RPD will return a value of zero."
        ::= { docsRphyRpdIfEnetSfpPlusStatusEntry 35 }
    Module imports
    {'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'IP-MIB': ['IpAddressOriginTC', 'IpAddressStatusTC', 'Ipv6AddressIfIdentifierTC'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'TimeStamp', 'DateAndTime', 'PhysAddress', 'TEXTUAL-CONVENTION'], 'ENTITY-MIB': ['PhysicalIndex', 'PhysicalIndexOrZero'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Gauge32', 'Counter32', 'Counter64', 'Integer32'], 'DOCS-IF-MIB': ['TenthdB', 'TenthdBmV'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE'], 'UUID-TC-MIB': ['UUIDorZero'], 'CLAB-DEF-MIB': ['clabProjDocsis'], 'DOCS-IF3-MIB': ['IfDirection', 'docsIf3CmtsCmRegStatusId'], 'IANAifType-MIB': ['IANAifType'], 'IANA-ENTITY-MIB': ['IANAPhysicalClass'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetVersion', 'InetAddressPrefixLength'], 'ENTITY-SENSOR-MIB': ['EntitySensorDataType', 'EntitySensorDataScale', 'EntitySensorPrecision', 'EntitySensorValue', 'EntitySensorStatus'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
    · Download DOCS-RPHY-MIB.mib
    Source location: DOCS-RPHY-MIB::docsRphyRpdIfEnetSfpPlusStatusMeasuredTemperature.
    Source version and references

    Downloaded: 2026-10-26T22:47:25.372984+00:00.

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Ralph Brown

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.4491)

Maria Stachelek

Siblings (35)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.1 docsRphyRpdIfEnetSfpPlusStatusStatus00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.2 docsRphyRpdIfEnetSfpPlusStatusIdentifier00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.3 docsRphyRpdIfEnetSfpPlusStatusExtendedIdentifier00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.4 docsRphyRpdIfEnetSfpPlusStatusConnectorType00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.5 docsRphyRpdIfEnetSfpPlusStatusTransceiverComplianceCodes00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.6 docsRphyRpdIfEnetSfpPlusStatusTransceiverComplianceCode3600
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.7 docsRphyRpdIfEnetSfpPlusStatusEncoding00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.8 docsRphyRpdIfEnetSfpPlusStatusBitRateNominal00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.9 docsRphyRpdIfEnetSfpPlusStatusRateIdentifier00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.10 docsRphyRpdIfEnetSfpPlusStatusLengthKm00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.11 docsRphyRpdIfEnetSfpPlusStatusLength100M00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.12 docsRphyRpdIfEnetSfpPlusStatusLength50Mi10M00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.13 docsRphyRpdIfEnetSfpPlusStatusLength62Pt5Mi10M00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.14 docsRphyRpdIfEnetSfpPlusStatusLengthCopperM00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.15 docsRphyRpdIfEnetSfpPlusStatusLength50MiOm300
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.16 docsRphyRpdIfEnetSfpPlusStatusVendorName00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.17 docsRphyRpdIfEnetSfpPlusStatusVendorOui00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.18 docsRphyRpdIfEnetSfpPlusStatusVendorPartNum00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.19 docsRphyRpdIfEnetSfpPlusStatusVendorSerialNum00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.20 docsRphyRpdIfEnetSfpPlusStatusVendorRev00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.21 docsRphyRpdIfEnetSfpPlusStatusLaserWavelength00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.22 docsRphyRpdIfEnetSfpPlusStatusOptions00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.23 docsRphyRpdIfEnetSfpPlusStatusBitRateMax00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.24 docsRphyRpdIfEnetSfpPlusStatusBitRateMin00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.25 docsRphyRpdIfEnetSfpPlusStatusVendorDate00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.26 docsRphyRpdIfEnetSfpPlusStatusVendorSpecificLotCode00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.27 docsRphyRpdIfEnetSfpPlusStatusDiagMonitorType00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.28 docsRphyRpdIfEnetSfpPlusStatusEnhancedOptions00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.29 docsRphyRpdIfEnetSfpPlusStatusSff8472Compliance00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.30 docsRphyRpdIfEnetSfpPlusStatusVendorSpecificData00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.31 docsRphyRpdIfEnetSfpPlusStatusMeasuredTxOutputPwr00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.32 docsRphyRpdIfEnetSfpPlusStatusMeasuredRxInputPwr00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.33 docsRphyRpdIfEnetSfpPlusStatusDigitalDiagA2Info00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.34 docsRphyRpdIfEnetSfpPlusStatusMeasuredTxBiasCurrent00
1.3.6.1.4.1.4491.2.1.30.1.2.8.1.36 docsRphyRpdIfEnetSfpPlusStatusMeasuredSupplyVoltage00