OID reference

alm3-del

1.3.6.1.4.1.9839.2.1.3.32

Description

Optional Alarm 3 Delay

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.9839.2.1.3 (integerObjects)
Node code
32
Node names
  • alm3-del
  • overlap-time-Pumps
  • conf_id_al_pb
  • time_min_compr_on
  • minmax_acq_time
  • t_buzzer_p4
  • ph_circ_type
  • min_tra_comp
  • p2
  • n_comp
  • comp_delay_c0
  • outl2
  • haccp_hf_day
  • bios_release
  • rall_rg_flux_p2
  • comp_on_tm_c3
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.9839.2.1.3.32
URN notation
urn:oid:1.3.6.1.4.1.9839.2.1.3.32
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 9839 2 1 3 32}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) integerObjects(3) alm3-del(32)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) integerObjects(3) overlap-time-Pumps(32)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) integerObjects(3) p2(32)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) integerObjects(3) outl2(32)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) integerObjects(3) alm3-del(32)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) integerObjects(3) overlap-time-Pumps(32)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) integerObjects(3) p2(32)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) integerObjects(3) outl2(32)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) integerObjects(3) alm3-del(32)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) integerObjects(3) overlap-time-Pumps(32)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) integerObjects(3) p2(32)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) integerObjects(3) outl2(32)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) integerObjects(3) alm3-del(32)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) integerObjects(3) overlap-time-Pumps(32)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) integerObjects(3) p2(32)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) integerObjects(3) outl2(32)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/9839/2/1/3/32
  • /ISO/Identified-Organization/6/1/4/1/9839/2/1/3/32
  • /ISO/3/6/1/4/1/9839/2/1/3/32
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/alm3-del
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/overlap-time-Pumps
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/conf_id_al_pb
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/time_min_compr_on
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/minmax_acq_time
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/t_buzzer_p4
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/ph_circ_type
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/min_tra_comp
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/p2
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/n_comp
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/comp_delay_c0
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/outl2
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/haccp_hf_day
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/bios_release
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/rall_rg_flux_p2
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/comp_on_tm_c3
  • Additional combinations skipped.

SNMP properties

Value type
Integer32
Units
min, N/A, flag, sec, hours
Maximum access defined by MIB
read-write, read-only
Status in MIB
current
Default value
0, 1, 2, 5, 10

Definitions may combine these properties differently.

Compare 12 source variants

Variant 1 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
min
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
0
Allowed ranges
0–15

Variant 2 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
0
Allowed ranges
0–1

Variant 3 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
0
Allowed ranges
0–65536

Variant 4 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
flag
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
1
Allowed ranges
0–6

Variant 5 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Default value
0
Allowed ranges
1–7

Variant 6 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-write
Status in MIB
current
Allowed ranges
0–999

Variant 7 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
2
Allowed ranges
0–2

Variant 8 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
sec
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
5
Allowed ranges
0–90

Variant 9 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Allowed ranges
-32767–32767

Variant 10 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
hours
Maximum access defined by MIB
read-only
Status in MIB
current
Allowed ranges
0–199

Variant 11 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Default value
0
Allowed ranges
0–32000

Variant 12 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
sec
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
10
Allowed ranges
0–9999

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.9839.2.1.3.32.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 16 distinct definitions; some records may not include a definition.

Show 16 published definitions

time_min_compr_on · current

time_min_compr_on OBJECT-TYPE
                    SYNTAX Integer32 (0..15)
                    UNITS "min"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Minimum time of compressor ON"
                    DEFVAL { 0 }
                    ::= { integerObjects 32 }

p2 · current

p2 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Digital input ID3 alarm type."
                    DEFVAL { 0 }
                    ::= { integerObjects 32 }

outl2 · current

outl2 OBJECT-TYPE
                    SYNTAX Integer32 (0..65536)
                    UNITS "N/A"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Mold of the output state in function of the alarms (2/2)"
                    DEFVAL { 0 }
                    ::= { integerObjects 32 }

conf_id_al_pb · current

conf_id_al_pb OBJECT-TYPE
                    SYNTAX Integer32 (0..6)
                    UNITS "flag"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Type of management of generic alarm input ID5"
                    DEFVAL { 1 }
                    ::= { integerObjects 32 }

haccp_hf_day · current

haccp_hf_day OBJECT-TYPE
                    SYNTAX Integer32 (1..7)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Weekday on which the HF event occurred"
                    DEFVAL { 0 }
                    ::= { integerObjects 32 }

comp_delay_c0 · current

comp_delay_c0 OBJECT-TYPE
                    SYNTAX Integer32 (0..15)
                    UNITS "min"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Compressor start delay at instrument on"
                    DEFVAL { 0 }
                    ::= { integerObjects 32 }

overlap-time-Pumps · current

overlap-time-Pumps OBJECT-TYPE
                    	SYNTAX Integer32 (0..999)
                    	UNITS "N/A"
                   		MAX-ACCESS read-write
                   		STATUS current
                    	DESCRIPTION "Overlap time Pumps"
                   		::= { integerObjects 32 }

n_comp · current

n_comp OBJECT-TYPE
                    SYNTAX Integer32 (0..2)
                    UNITS "N/A"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Compressor no."
                    DEFVAL { 2 }
                    ::= { integerObjects 32 }

rall_rg_flux_p2 · current

rall_rg_flux_p2 OBJECT-TYPE
                    SYNTAX Integer32 (0..90)
                    UNITS "sec"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Flowswitch alarm delayed during normal operating"
                    DEFVAL { 5 }
                    ::= { integerObjects 32 }

bios_release · current

bios_release OBJECT-TYPE
                    SYNTAX Integer32 (-32767..32767)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Version of bios used"
                    ::= { integerObjects 32 }

minmax_acq_time · current

minmax_acq_time OBJECT-TYPE
                    SYNTAX Integer32 (0..199)
                    UNITS "hours"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Actual interval in max/min. temperature reading"
                    ::= { integerObjects 32 }

alm3-del · current

alm3-del OBJECT-TYPE
                    SYNTAX Integer32 (0..32000)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Optional Alarm 3 Delay"
                    DEFVAL { 0 }
                    ::= { integerObjects 32 }

ph_circ_type · current

ph_circ_type OBJECT-TYPE
                    SYNTAX Integer32 (-32767..32767)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Type of circuit (physical)"
                    ::= { integerObjects 32 }

t_buzzer_p4 · current

t_buzzer_p4 OBJECT-TYPE
                    SYNTAX Integer32 (0..15)
                    UNITS "min"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Buzzer ON"
                    DEFVAL { 0 }
                    ::= { integerObjects 32 }

min_tra_comp · current

min_tra_comp OBJECT-TYPE
                    SYNTAX Integer32 (0..9999)
                    UNITS "sec"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Minimun time between 2 atart-ups of different compressor"
                    DEFVAL { 10 }
                    ::= { integerObjects 32 }

comp_on_tm_c3 · current

comp_on_tm_c3 OBJECT-TYPE
                    SYNTAX Integer32 (0..15)
                    UNITS "min"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Minimum compressor on time"
                    DEFVAL { 0 }
                    ::= { integerObjects 32 }

Meaning

Descriptions

16 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Optional Alarm 3 Delay
Original text from OID Repository
alm3-del OBJECT-TYPE
SYNTAX Integer32 (0..32000)
UNITS "N/A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Optional Alarm 3 Delay"
DEFVAL { 0 }
Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

OID Repository

View at oid-base.com

Description 2

Minimum time of compressor ON

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 3

Digital input ID3 alarm type.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 4

Mold of the output state in function of the alarms (2/2)

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 5

Type of management of generic alarm input ID5

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 6

Weekday on which the HF event occurred

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 7

Compressor start delay at instrument on

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 8

Overlap time Pumps

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 9

Compressor no.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 10

Flowswitch alarm delayed during normal operating

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 11

Version of bios used

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 12

Actual interval in max/min. temperature reading

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 13

Type of circuit (physical)

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 14

Buzzer ON

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 15

Minimun time between 2 atart-ups of different compressor

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 16

Minimum compressor on time

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

16 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 2Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 2

time_min_compr_on · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: time_min_compr_on

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "time_min_compr_on",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "15",
    ")",
    "UNITS",
    [
      "literal",
      "226d696e22"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Minimum time of compressor ON\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "32",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            15
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "min"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Minimum time of compressor ON"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 3Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 3

p2 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: p2

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "p2",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Digital input ID3 alarm type.\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "32",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Digital input ID3 alarm type."
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 4Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 4

outl2 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: outl2

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "outl2",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "65536",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Mold of the output state in function of the alarms (2/2)\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "32",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            65536
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Mold of the output state in function of the alarms (2/2)"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 5Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 5

conf_id_al_pb · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: conf_id_al_pb

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "conf_id_al_pb",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "6",
    ")",
    "UNITS",
    [
      "literal",
      "22666c616722"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Type of management of generic alarm input ID5\"",
    "DEFVAL",
    "{",
    "1",
    "}",
    "::=",
    "{",
    "integerObjects",
    "32",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            6
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "flag"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Type of management of generic alarm input ID5"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      1
    ]
  ]
}
Records for description 6Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 6

haccp_hf_day · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: haccp_hf_day

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "haccp_hf_day",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "1",
    ".",
    ".",
    "7",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Weekday on which the HF event occurred\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "32",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            1,
            7
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Weekday on which the HF event occurred"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 7Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 7

comp_delay_c0 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: comp_delay_c0

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "comp_delay_c0",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "15",
    ")",
    "UNITS",
    [
      "literal",
      "226d696e22"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Compressor start delay at instrument on\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "32",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            15
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "min"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Compressor start delay at instrument on"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 8Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 8

overlap-time-Pumps · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: overlap-time-Pumps

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "overlap-time-Pumps",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "999",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Overlap time Pumps\"",
    "::=",
    "{",
    "integerObjects",
    "32",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            999
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Overlap time Pumps"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 9Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 9

n_comp · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: n_comp

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "n_comp",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "2",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Compressor no.\"",
    "DEFVAL",
    "{",
    "2",
    "}",
    "::=",
    "{",
    "integerObjects",
    "32",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            2
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Compressor no."
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      2
    ]
  ]
}
Records for description 10Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 10

rall_rg_flux_p2 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: rall_rg_flux_p2

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rall_rg_flux_p2",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "90",
    ")",
    "UNITS",
    [
      "literal",
      "2273656322"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Flowswitch alarm delayed during normal operating\"",
    "DEFVAL",
    "{",
    "5",
    "}",
    "::=",
    "{",
    "integerObjects",
    "32",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            90
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "sec"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Flowswitch alarm delayed during normal operating"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      5
    ]
  ]
}
Records for description 11Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 11

bios_release · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: bios_release

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "bios_release",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "32767",
    ".",
    ".",
    "32767",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Version of bios used\"",
    "::=",
    "{",
    "integerObjects",
    "32",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -32767,
            32767
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Version of bios used"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 12Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 12

minmax_acq_time · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: minmax_acq_time

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "minmax_acq_time",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "199",
    ")",
    "UNITS",
    [
      "literal",
      "22686f75727322"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Actual interval in max/min. temperature reading\"",
    "::=",
    "{",
    "integerObjects",
    "32",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            199
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "hours"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Actual interval in max/min. temperature reading"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 1

alm3-del · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)2 sources

Status in source: current.

Names: alm3-del

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "alm3-del",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "32000",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Optional Alarm 3 Delay\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "32",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            32000
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Optional Alarm 3 Delay"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 13Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 13

ph_circ_type · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: ph_circ_type

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ph_circ_type",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "32767",
    ".",
    ".",
    "32767",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Type of circuit (physical)\"",
    "::=",
    "{",
    "integerObjects",
    "32",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -32767,
            32767
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Type of circuit (physical)"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 14Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 14

t_buzzer_p4 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: t_buzzer_p4

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "t_buzzer_p4",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "15",
    ")",
    "UNITS",
    [
      "literal",
      "226d696e22"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Buzzer ON\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "32",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            15
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "min"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Buzzer ON"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 15Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 15

min_tra_comp · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: min_tra_comp

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "min_tra_comp",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "9999",
    ")",
    "UNITS",
    [
      "literal",
      "2273656322"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Minimun time between 2 atart-ups of different compressor\"",
    "DEFVAL",
    "{",
    "10",
    "}",
    "::=",
    "{",
    "integerObjects",
    "32",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            9999
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "sec"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Minimun time between 2 atart-ups of different compressor"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      10
    ]
  ]
}
Records for description 16Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 16

comp_on_tm_c3 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: comp_on_tm_c3

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "comp_on_tm_c3",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "15",
    ")",
    "UNITS",
    [
      "literal",
      "226d696e22"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Minimum compressor on time\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "32",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            15
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "min"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Minimum compressor on time"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.9839)

Fiorindo Sebastiano

Siblings (121)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.9839.2.1.3.52 wtrvlv-sel, time-Min-Different-Freecooling-Chiller-timing, max_volt_f3, durata_pulizia, rit_acc_comp, p5, sgl_ore_comp2, defrost_t6_hh, lt_al_thrsh_al00 Water valve type 0=none, 1=chill, 2=Engy, 3=Aux chill, 4=Disc Reg
1.3.6.1.4.1.9839.2.1.3.53 wtrvlv-volts-sel, time-Min-Same-Freecooling-Chiller-timing, triac_durat_f4, par_ora1, th, rit_spegn_comp, p9, defrost_t6_mm, sg_ore_comp, di1_config_a400 Water valve voltage 0= 0-10, 1=2-10, 2=7-10, 3=6-9, 4=4-7
1.3.6.1.4.1.9839.2.1.3.54 hum-volts, integral-Time-Freeccoling-Valve-PID, min_out_val_f7, par_ora2, tdow, p10, in_rampa_p3v, tm, hour_comp1, di2_config_a500 % of 10volts of analog output #2
1.3.6.1.4.1.9839.2.1.3.55 dehum-hours-h, derivative-Time-Freeccoling-Valve-PID, max_out_val_f8, manual_position, p11, fin_rampa_p3v, th, hour_l_comp1, comp_off_ext_a600 Dehumidifier Runtime - High
1.3.6.1.4.1.9839.2.1.3.56 dehum-hours-l, output-Address-Valve-Freecooling, min_on_time_c1, posizione_valvola_perc, tempo_acc_pompa, p6, in_rampa_n3v, td, hour_comp2, tm_delay_id_a700 Dehumidifier Runtime - Low
1.3.6.1.4.1.9839.2.1.3.57 delay-Freecooling-Thermal-Exclusion, min_off_time_c2, modello_valvola, h7, fin_rampa_n3v, hour_l_comp2, temp_al_del_ad00
1.3.6.1.4.1.9839.2.1.3.58 autoflush-dly, n-of-alarm-External-Dry-Cooler, t_betw_2_on_c3, ti_int, tempo_run, hour_comp3, cnf_di_virt_a800 Time between drain cycles 0=12hr, 1=24hr, 2=48hr, 3=96hr, 4=None
1.3.6.1.4.1.9839.2.1.3.59 y4-out, delay-Alarm-Static-Pressure, t_comp_2_on_c4, ti_low, h13, rit_syson, hour_l_comp3, en_lan_di2_a900 Value sent to optional analog output#1
1.3.6.1.4.1.9839.2.1.3.60 y5-out, n-of-Alarm-Static-Pressure, t_comp_2_off_c5, tipogas, h6, hour_comp4, en_mt_al_slv_ra00 Value sent to optional analog output#2
1.3.6.1.4.1.9839.2.1.3.61 air-flow, delay-Warning-Static-Pressure, t_comp_fan_c7, delay_pressure_probe_alarm, h10, vr1cen, hour_l_comp4, fans_mng_f000 Current Fan Airflow - Based on calculated Pressure Diff formula
1.3.6.1.4.1.9839.2.1.3.62 opt-snsr1-name, n-of-Warning-Static-Pressure, off_fan_d_fd, tipo_sonda_eva, vr2cen, hour_comp500 Name of the sensor
1.3.6.1.4.1.9839.2.1.3.63 opt-sns-1-ain-type, n-of-Alarm-Differential-Pressure, on_dalay_hg, ore_mac, hour_l_comp5, fan_0_cmp_0_f200 Analog Sensor 1 Type {0=NTC 1=PT1000 2=0-1VDC 3=0-10VDC 4=4-20mA 5=ON/OFF 6=0-5VDC 7=NTC HT 8=-50T90 9=10T170}
1.3.6.1.4.1.9839.2.1.3.64 opt-snsr2-name, priming-Time-Hydraulic-Pressure, en_rotat_c6, cmp_start_valve_position, hour_comp6, fan_0_on_def_f300 Name of the sensor
1.3.6.1.4.1.9839.2.1.3.65 opt-sns-2-ain-type, delay-priming-Time-Hydraulic-Pressure, d_flow_s_p1, dd_1, ore_comp1, hour_l_comp6, fan_rele_f400 Analog Sensor 2 Type {0=NTC 1=PT1000 2=0-1VDC 3=0-10VDC 4=4-20mA 5=ON/OFF 6=0-5VDC 7=NTC HT 8=-50T90 9=10T170}
1.3.6.1.4.1.9839.2.1.3.66 opt-snsr3-name, output-Address-Alarm-Static-Pressure, d_flow_run_p2, hh_1, ore_comp2, h_hour_fan1, tm_off_drip_fd00 Name of the sensor
1.3.6.1.4.1.9839.2.1.3.67 opt-sns-3-ain-type, n-of-Alarm-Flow-Rate, lp_delay_p3, mm_1, h1, x_h_main_fan, l_hour_fan100 Analog Sensor 3 Type {0=NTC 1=PT1000 2=0-1VDC 3=0-10VDC 4=4-20mA 5=ON/OFF 6=0-5VDC 7=NTC HT 8=-50T90 9=10T170}
1.3.6.1.4.1.9839.2.1.3.68 opt-snsr4-name, priming-Time-Flow-Rate, al_prb_delay_pa, dd_2, h2, x_h_valve_comp1, h_hour_fan2, relay4_mode_h100 Name of the sensor
1.3.6.1.4.1.9839.2.1.3.69 opt-sns-4-ain-type, delay-priming-Time-Flow-Rate, al_gen_delay_pc, hh_2, x_h_valve_comp2, l_hour_fan2, en_dis_keyb_h200 Analog Sensor 4 Type {0=NTC 1=PT1000 2=0-1VDC 3=0-10VDC 4=4-20mA 5=ON/OFF 6=0-5VDC 7=NTC HT 8=-50T90 9=10T170}
1.3.6.1.4.1.9839.2.1.3.70 cw-fan-speed-bms, bms-address-IDENT, t_slot_cfg_rt, mm_2, f5, h_hour_fan3, remote_control00 CW Fan speed (%) sent via BMS
1.3.6.1.4.1.9839.2.1.3.71 dx-fan-speed-bms, fan_time_fe, dd_3, d1, l_hour_fan300 DX Fan speed (%) sent via BMS
1.3.6.1.4.1.9839.2.1.3.72 fan-speed-max, abilitazione_allarme_fumo, hh_3, d2, h_hour_fan400 Maximum Fan speed (% of output) modulation.
1.3.6.1.4.1.9839.2.1.3.73 fan-speed-min, abilitazione_allarme_cf, mm_3, d5, l_hour_fan400 Minimum Fan speed (% of output) modulation from pressure.
1.3.6.1.4.1.9839.2.1.3.74 fan-pr-sp, abilitazione_allarme_ht, dd_4, d6, sg_ore_fan, lan_address_sa00 Fan pressure setpoint (0.01 inches of water)
1.3.6.1.4.1.9839.2.1.3.75 fan-pr-band, hh_4, d7, version, lan_lenght_sn00 Fan pressure band (0.01 inches of water)
1.3.6.1.4.1.9839.2.1.3.76 fan-af-max, mm_4, d8, h_hour_fan5, hh_def_sched100 Maximum air flow limit of setpoint from BMS or valve modulation.
1.3.6.1.4.1.9839.2.1.3.77 fan-af-min, dd_5, d9, l_hour_fan5, mm_def_sched100 Minimum air flow limit of setpoint from BMS or valve modulation.
1.3.6.1.4.1.9839.2.1.3.78 fan-kfactor, hh_5, d10, time_on_black_out, hh_def_sched200 Fan K Factor
1.3.6.1.4.1.9839.2.1.3.79 num-fans, mm_5, d12, config_in1, mm_def_sched200 Number of fans installed in this unit
1.3.6.1.4.1.9839.2.1.3.80 dd_6, d13, config_in2, hh_def_sched300
1.3.6.1.4.1.9839.2.1.3.81 ht2-hours-h, hh_6, config_in3, mm_def_sched300 Heater 2 Runtime - high
1.3.6.1.4.1.9839.2.1.3.82 ht2-hours-l, mm_6, config_in4, hh_def_sched400 Heater 2 Runtime - low
1.3.6.1.4.1.9839.2.1.3.83 ht3-hours-h, dd_7, r27, config_in5, mm_def_sched400 Heater 3 Runtime - high
1.3.6.1.4.1.9839.2.1.3.84 ht3-hours-l, hh_7, l4, config_in6, hh_def_sched500 Heater 3 Runtime - low
1.3.6.1.4.1.9839.2.1.3.85 engy-hours-h, mm_7, h16, config_in7, mm_def_sched500 Energy Saver Runtime - This optional point applies to energy saver units only -high
1.3.6.1.4.1.9839.2.1.3.86 engy-hours-l, dd_8, p12, config_in8, hh_def_sched600 Energy Saver Runtime - This optional point applies to energy saver units only - low
1.3.6.1.4.1.9839.2.1.3.87 cw-hours-h, hh_8, l1, config_in9, mm_def_sched600 Chilled Water Runtime - This applies to chilled water units only - high
1.3.6.1.4.1.9839.2.1.3.88 cw-hours-l, mm_8, l2, config_in10, hh_def_sched700 Chilled Water Runtime - This applies to chilled water units only - low
1.3.6.1.4.1.9839.2.1.3.89 c3-hours-h, l3, config_in11, mm_def_sched700 Compressor 3 Runtime - This applies when unit has four stages tandem compressors - high
1.3.6.1.4.1.9839.2.1.3.90 c3-hours-l, l5, config_in12, hh_def_sched800 Compressor 3 Runtime - This applies when unit has four stages tandem compressors - low
1.3.6.1.4.1.9839.2.1.3.91 c4-hours-l, r14, config_in13, mm_def_sched800 Compressor 4 Runtime - This applies when unit has four stages tandem compressors. - high
1.3.6.1.4.1.9839.2.1.3.92 c4-hours-h, config_in14, hh_clock00 Compressor 4 Runtime - This applies when unit has four stages tandem compressors. - low
1.3.6.1.4.1.9839.2.1.3.93 cond-hours-h, config_in15, mm_clock00 Condenser Runtime - high
1.3.6.1.4.1.9839.2.1.3.94 cond-hours-l, config_in16, hh_vis00 Condenser Runtime - low
1.3.6.1.4.1.9839.2.1.3.95 dx-fan-speed, config_in17, mm_vis00 Fan speed (% of output) when compressor cooling.
1.3.6.1.4.1.9839.2.1.3.96 cw-fan-speed, config_in1800 Fan speed (% of output) when cold water cooling.
1.3.6.1.4.1.9839.2.1.3.97 fan-af-dx-sp, config_out100 Fan air flow setpoint for DX unit (cfm)
1.3.6.1.4.1.9839.2.1.3.98 fan-af-cw-sp, config_out200 Fan air flow setpoint for CW unit (cfm)
1.3.6.1.4.1.9839.2.1.3.99 zm-airflow-sp, chiller-name0, config_out300 Zone Airflow Setpoint kcfm
1.3.6.1.4.1.9839.2.1.3.100 chiller-name1, config_out400
1.3.6.1.4.1.9839.2.1.3.101 config_out500