OID reference

alarm1-txt

1.3.6.1.4.1.9839.2.1.3.33

Description

Message on optional alarm screen, some also add function

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.9839.2.1.3 (integerObjects)
Node code
33
Node names
  • alarm1-txt
  • working-time-Pumps
  • un_rot_num_h2
  • sicurezza_rele
  • haccp_ha_day
  • riprist_all_p5
  • n_comps
  • min_acc_comp
  • s7
  • rit_hl
  • t_al_delay_ad
  • priority
  • haccp_hf_hour
  • bios_date
  • rit_all_bp_p3
  • relay_safety_c4
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.9839.2.1.3.33
URN notation
urn:oid:1.3.6.1.4.1.9839.2.1.3.33
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 9839 2 1 3 33}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) integerObjects(3) alarm1-txt(33)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) integerObjects(3) working-time-Pumps(33)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) integerObjects(3) s7(33)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) integerObjects(3) priority(33)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) integerObjects(3) alarm1-txt(33)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) integerObjects(3) working-time-Pumps(33)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) integerObjects(3) s7(33)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) integerObjects(3) priority(33)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) integerObjects(3) alarm1-txt(33)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) integerObjects(3) working-time-Pumps(33)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) integerObjects(3) s7(33)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) integerObjects(3) priority(33)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) integerObjects(3) alarm1-txt(33)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) integerObjects(3) working-time-Pumps(33)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) integerObjects(3) s7(33)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) integerObjects(3) priority(33)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/9839/2/1/3/33
  • /ISO/Identified-Organization/6/1/4/1/9839/2/1/3/33
  • /ISO/3/6/1/4/1/9839/2/1/3/33
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/alarm1-txt
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/working-time-Pumps
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/un_rot_num_h2
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/sicurezza_rele
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/haccp_ha_day
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/riprist_all_p5
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/n_comps
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/min_acc_comp
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/s7
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/rit_hl
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/t_al_delay_ad
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/priority
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/haccp_hf_hour
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/bios_date
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/rit_all_bp_p3
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/integerObjects/relay_safety_c4
  • Additional combinations skipped.

SNMP properties

Value type
Integer32
Units
N/A, ore, flag, min, sec, gg
Maximum access defined by MIB
read-write, read-only
Status in MIB
current
Default value
0, 60, 600, 40, 1, 4

Definitions may combine these properties differently.

Compare 16 source variants

Variant 1 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
0
Allowed ranges
0–1

Variant 2 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
ore
Maximum access defined by MIB
read-only
Status in MIB
current
Default value
0
Allowed ranges
0–23

Variant 3 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
0
Allowed ranges
0–15

Variant 4 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
flag
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
0
Allowed ranges
0–6

Variant 5 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
min
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
0
Allowed ranges
0–100

Variant 6 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
sec
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
60
Allowed ranges
0–9999

Variant 7 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Allowed ranges
-32767–32767

Variant 8 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-write
Status in MIB
current
Allowed ranges
1–9999

Variant 9 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
sec
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
600
Allowed ranges
0–9999

Variant 10 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
min
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
0
Allowed ranges
0–199

Variant 11 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
flag
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
0
Allowed ranges
0–4

Variant 12 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
sec
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
40
Allowed ranges
0–150

Variant 13 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
1
Allowed ranges
1–8

Variant 14 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Default value
0
Allowed ranges
0–16

Variant 15 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
min
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
4
Allowed ranges
0–100

Variant 16 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
gg
Maximum access defined by MIB
read-only
Status in MIB
current
Allowed ranges
1–7

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.9839.2.1.3.33.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 16 distinct definitions; some records may not include a definition.

Show 16 published definitions

s7 · current

s7 OBJECT-TYPE
                    SYNTAX Integer32 (0..1)
                    UNITS "N/A"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Temperature °C/°F unit selection."
                    DEFVAL { 0 }
                    ::= { integerObjects 33 }

haccp_hf_hour · current

haccp_hf_hour OBJECT-TYPE
                    SYNTAX Integer32 (0..23)
                    UNITS "ore"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Hours at which the HF event occurred"
                    DEFVAL { 0 }
                    ::= { integerObjects 33 }

priority · current

priority OBJECT-TYPE
                    SYNTAX Integer32 (0..15)
                    UNITS "N/A"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Priority of the output state in case of multiple alarms"
                    DEFVAL { 0 }
                    ::= { integerObjects 33 }

un_rot_num_h2 · current

un_rot_num_h2 OBJECT-TYPE
                    SYNTAX Integer32 (0..6)
                    UNITS "flag"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "N. of machines in rotation"
                    DEFVAL { 0 }
                    ::= { integerObjects 33 }

sicurezza_rele · current

sicurezza_rele OBJECT-TYPE
                    SYNTAX Integer32 (0..100)
                    UNITS "min"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Duty setting safety function"
                    DEFVAL { 0 }
                    ::= { integerObjects 33 }

min_acc_comp · current

min_acc_comp OBJECT-TYPE
                    SYNTAX Integer32 (0..9999)
                    UNITS "sec"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Minimun compressor ON time"
                    DEFVAL { 60 }
                    ::= { integerObjects 33 }

bios_date · current

bios_date OBJECT-TYPE
                    SYNTAX Integer32 (-32767..32767)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Date of bios used"
                    ::= { integerObjects 33 }

working-time-Pumps · current

working-time-Pumps OBJECT-TYPE
                    	SYNTAX Integer32 (1..9999)
                    	UNITS "N/A"
                   		MAX-ACCESS read-write
                   		STATUS current
                    	DESCRIPTION "Working time Pumps"
                   		::= { integerObjects 33 }

rit_hl · current

rit_hl OBJECT-TYPE
                    SYNTAX Integer32 (0..9999)
                    UNITS "sec"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "High / low temperature / humidity alarm delay"
                    DEFVAL { 600 }
                    ::= { integerObjects 33 }

t_al_delay_ad · current

t_al_delay_ad OBJECT-TYPE
                    SYNTAX Integer32 (0..199)
                    UNITS "min"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Temperature alarm delay"
                    DEFVAL { 0 }
                    ::= { integerObjects 33 }

riprist_all_p5 · current

riprist_all_p5 OBJECT-TYPE
                    SYNTAX Integer32 (0..4)
                    UNITS "flag"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Reset of alarms"
                    DEFVAL { 0 }
                    ::= { integerObjects 33 }

rit_all_bp_p3 · current

rit_all_bp_p3 OBJECT-TYPE
                    SYNTAX Integer32 (0..150)
                    UNITS "sec"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Low pressure alarm delayed at compr. start-up"
                    DEFVAL { 40 }
                    ::= { integerObjects 33 }

n_comps · current

n_comps OBJECT-TYPE
                    SYNTAX Integer32 (1..8)
                    UNITS "N/A"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Total number of compressors on the machine"
                    DEFVAL { 1 }
                    ::= { integerObjects 33 }

alarm1-txt · current

alarm1-txt OBJECT-TYPE
                    SYNTAX Integer32 (0..16)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Message on optional alarm screen, some also add function"
                    DEFVAL { 0 }
                    ::= { integerObjects 33 }

relay_safety_c4 · current

relay_safety_c4 OBJECT-TYPE
                    SYNTAX Integer32 (0..100)
                    UNITS "min"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Relay safety"
                    DEFVAL { 4 }
                    ::= { integerObjects 33 }

haccp_ha_day · current

haccp_ha_day OBJECT-TYPE
                    SYNTAX Integer32 (1..7)
                    UNITS "gg"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Event - day of week HA"
                    ::= { integerObjects 33 }

Meaning

Descriptions

16 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Message on optional alarm screen, some also add function
Original text from OID Repository
alarm1-txt OBJECT-TYPE
SYNTAX Integer32 (0..16)
UNITS "N/A"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Message on optional alarm screen, some also add function"
DEFVAL { 0 }
Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

OID Repository

View at oid-base.com

Description 2

Temperature °C/°F unit selection.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 3

Hours at which the HF event occurred

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 4

Priority of the output state in case of multiple alarms

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 5

N. of machines in rotation

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 6

Duty setting safety function

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 7

Minimun compressor ON time

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 8

Date of bios used

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 9

Working time Pumps

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 10

High / low temperature / humidity alarm delay

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 11

Temperature alarm delay

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 12

Reset of alarms

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 13

Low pressure alarm delayed at compr. start-up

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 14

Total number of compressors on the machine

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 15

Relay safety

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 16

Event - day of week HA

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

16 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 2Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 2

s7 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: s7

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "s7",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "1",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Temperature °C/°F unit selection.\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "33",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            1
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Temperature °C/°F unit selection."
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 3Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 3

haccp_hf_hour · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: haccp_hf_hour

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "haccp_hf_hour",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "23",
    ")",
    "UNITS",
    [
      "literal",
      "226f726522"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Hours at which the HF event occurred\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "33",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            23
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "ore"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Hours at which the HF event occurred"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 4Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 4

priority · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: priority

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "priority",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "15",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Priority of the output state in case of multiple alarms\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "33",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            15
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Priority of the output state in case of multiple alarms"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 5Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 5

un_rot_num_h2 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: un_rot_num_h2

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "un_rot_num_h2",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "6",
    ")",
    "UNITS",
    [
      "literal",
      "22666c616722"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"N. of machines in rotation\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "33",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            6
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "flag"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "N. of machines in rotation"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 6Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 6

sicurezza_rele · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: sicurezza_rele

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "sicurezza_rele",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "100",
    ")",
    "UNITS",
    [
      "literal",
      "226d696e22"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Duty setting safety function\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "33",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            100
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "min"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Duty setting safety function"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 7Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 7

min_acc_comp · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: min_acc_comp

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "min_acc_comp",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "9999",
    ")",
    "UNITS",
    [
      "literal",
      "2273656322"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Minimun compressor ON time\"",
    "DEFVAL",
    "{",
    "60",
    "}",
    "::=",
    "{",
    "integerObjects",
    "33",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            9999
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "sec"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Minimun compressor ON time"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      60
    ]
  ]
}
Records for description 8Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 8

bios_date · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: bios_date

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "bios_date",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "32767",
    ".",
    ".",
    "32767",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Date of bios used\"",
    "::=",
    "{",
    "integerObjects",
    "33",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -32767,
            32767
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Date of bios used"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 9Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 9

working-time-Pumps · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: working-time-Pumps

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "working-time-Pumps",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "1",
    ".",
    ".",
    "9999",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Working time Pumps\"",
    "::=",
    "{",
    "integerObjects",
    "33",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            1,
            9999
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Working time Pumps"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 10Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 10

rit_hl · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: rit_hl

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rit_hl",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "9999",
    ")",
    "UNITS",
    [
      "literal",
      "2273656322"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"High / low temperature / humidity alarm delay\"",
    "DEFVAL",
    "{",
    "600",
    "}",
    "::=",
    "{",
    "integerObjects",
    "33",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            9999
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "sec"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "High / low temperature / humidity alarm delay"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      600
    ]
  ]
}
Records for description 11Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 11

t_al_delay_ad · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: t_al_delay_ad

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "t_al_delay_ad",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "199",
    ")",
    "UNITS",
    [
      "literal",
      "226d696e22"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Temperature alarm delay\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "33",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            199
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "min"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Temperature alarm delay"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 12Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 12

riprist_all_p5 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: riprist_all_p5

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "riprist_all_p5",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "4",
    ")",
    "UNITS",
    [
      "literal",
      "22666c616722"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Reset of alarms\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "33",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            4
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "flag"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Reset of alarms"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 13Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 13

rit_all_bp_p3 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: rit_all_bp_p3

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rit_all_bp_p3",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "150",
    ")",
    "UNITS",
    [
      "literal",
      "2273656322"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Low pressure alarm delayed at compr. start-up\"",
    "DEFVAL",
    "{",
    "40",
    "}",
    "::=",
    "{",
    "integerObjects",
    "33",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            150
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "sec"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Low pressure alarm delayed at compr. start-up"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      40
    ]
  ]
}
Records for description 14Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 14

n_comps · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: n_comps

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "n_comps",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "1",
    ".",
    ".",
    "8",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Total number of compressors on the machine\"",
    "DEFVAL",
    "{",
    "1",
    "}",
    "::=",
    "{",
    "integerObjects",
    "33",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            1,
            8
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Total number of compressors on the machine"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      1
    ]
  ]
}
Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 1

alarm1-txt · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)2 sources

Status in source: current.

Names: alarm1-txt

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "alarm1-txt",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "16",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Message on optional alarm screen, some also add function\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "integerObjects",
    "33",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            16
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Message on optional alarm screen, some also add function"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 15Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 15

relay_safety_c4 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: relay_safety_c4

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "relay_safety_c4",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "100",
    ")",
    "UNITS",
    [
      "literal",
      "226d696e22"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Relay safety\"",
    "DEFVAL",
    "{",
    "4",
    "}",
    "::=",
    "{",
    "integerObjects",
    "33",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            100
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "min"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Relay safety"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      4
    ]
  ]
}
Records for description 16Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 16

haccp_ha_day · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: haccp_ha_day

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "haccp_ha_day",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "1",
    ".",
    ".",
    "7",
    ")",
    "UNITS",
    [
      "literal",
      "22676722"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Event - day of week HA\"",
    "::=",
    "{",
    "integerObjects",
    "33",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            1,
            7
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "gg"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Event - day of week HA"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.9839)

Fiorindo Sebastiano

Siblings (121)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.9839.2.1.3.52 wtrvlv-sel, time-Min-Different-Freecooling-Chiller-timing, max_volt_f3, durata_pulizia, rit_acc_comp, p5, sgl_ore_comp2, defrost_t6_hh, lt_al_thrsh_al00 Water valve type 0=none, 1=chill, 2=Engy, 3=Aux chill, 4=Disc Reg
1.3.6.1.4.1.9839.2.1.3.53 wtrvlv-volts-sel, time-Min-Same-Freecooling-Chiller-timing, triac_durat_f4, par_ora1, th, rit_spegn_comp, p9, defrost_t6_mm, sg_ore_comp, di1_config_a400 Water valve voltage 0= 0-10, 1=2-10, 2=7-10, 3=6-9, 4=4-7
1.3.6.1.4.1.9839.2.1.3.54 hum-volts, integral-Time-Freeccoling-Valve-PID, min_out_val_f7, par_ora2, tdow, p10, in_rampa_p3v, tm, hour_comp1, di2_config_a500 % of 10volts of analog output #2
1.3.6.1.4.1.9839.2.1.3.55 dehum-hours-h, derivative-Time-Freeccoling-Valve-PID, max_out_val_f8, manual_position, p11, fin_rampa_p3v, th, hour_l_comp1, comp_off_ext_a600 Dehumidifier Runtime - High
1.3.6.1.4.1.9839.2.1.3.56 dehum-hours-l, output-Address-Valve-Freecooling, min_on_time_c1, posizione_valvola_perc, tempo_acc_pompa, p6, in_rampa_n3v, td, hour_comp2, tm_delay_id_a700 Dehumidifier Runtime - Low
1.3.6.1.4.1.9839.2.1.3.57 delay-Freecooling-Thermal-Exclusion, min_off_time_c2, modello_valvola, h7, fin_rampa_n3v, hour_l_comp2, temp_al_del_ad00
1.3.6.1.4.1.9839.2.1.3.58 autoflush-dly, n-of-alarm-External-Dry-Cooler, t_betw_2_on_c3, ti_int, tempo_run, hour_comp3, cnf_di_virt_a800 Time between drain cycles 0=12hr, 1=24hr, 2=48hr, 3=96hr, 4=None
1.3.6.1.4.1.9839.2.1.3.59 y4-out, delay-Alarm-Static-Pressure, t_comp_2_on_c4, ti_low, h13, rit_syson, hour_l_comp3, en_lan_di2_a900 Value sent to optional analog output#1
1.3.6.1.4.1.9839.2.1.3.60 y5-out, n-of-Alarm-Static-Pressure, t_comp_2_off_c5, tipogas, h6, hour_comp4, en_mt_al_slv_ra00 Value sent to optional analog output#2
1.3.6.1.4.1.9839.2.1.3.61 air-flow, delay-Warning-Static-Pressure, t_comp_fan_c7, delay_pressure_probe_alarm, h10, vr1cen, hour_l_comp4, fans_mng_f000 Current Fan Airflow - Based on calculated Pressure Diff formula
1.3.6.1.4.1.9839.2.1.3.62 opt-snsr1-name, n-of-Warning-Static-Pressure, off_fan_d_fd, tipo_sonda_eva, vr2cen, hour_comp500 Name of the sensor
1.3.6.1.4.1.9839.2.1.3.63 opt-sns-1-ain-type, n-of-Alarm-Differential-Pressure, on_dalay_hg, ore_mac, hour_l_comp5, fan_0_cmp_0_f200 Analog Sensor 1 Type {0=NTC 1=PT1000 2=0-1VDC 3=0-10VDC 4=4-20mA 5=ON/OFF 6=0-5VDC 7=NTC HT 8=-50T90 9=10T170}
1.3.6.1.4.1.9839.2.1.3.64 opt-snsr2-name, priming-Time-Hydraulic-Pressure, en_rotat_c6, cmp_start_valve_position, hour_comp6, fan_0_on_def_f300 Name of the sensor
1.3.6.1.4.1.9839.2.1.3.65 opt-sns-2-ain-type, delay-priming-Time-Hydraulic-Pressure, d_flow_s_p1, dd_1, ore_comp1, hour_l_comp6, fan_rele_f400 Analog Sensor 2 Type {0=NTC 1=PT1000 2=0-1VDC 3=0-10VDC 4=4-20mA 5=ON/OFF 6=0-5VDC 7=NTC HT 8=-50T90 9=10T170}
1.3.6.1.4.1.9839.2.1.3.66 opt-snsr3-name, output-Address-Alarm-Static-Pressure, d_flow_run_p2, hh_1, ore_comp2, h_hour_fan1, tm_off_drip_fd00 Name of the sensor
1.3.6.1.4.1.9839.2.1.3.67 opt-sns-3-ain-type, n-of-Alarm-Flow-Rate, lp_delay_p3, mm_1, h1, x_h_main_fan, l_hour_fan100 Analog Sensor 3 Type {0=NTC 1=PT1000 2=0-1VDC 3=0-10VDC 4=4-20mA 5=ON/OFF 6=0-5VDC 7=NTC HT 8=-50T90 9=10T170}
1.3.6.1.4.1.9839.2.1.3.68 opt-snsr4-name, priming-Time-Flow-Rate, al_prb_delay_pa, dd_2, h2, x_h_valve_comp1, h_hour_fan2, relay4_mode_h100 Name of the sensor
1.3.6.1.4.1.9839.2.1.3.69 opt-sns-4-ain-type, delay-priming-Time-Flow-Rate, al_gen_delay_pc, hh_2, x_h_valve_comp2, l_hour_fan2, en_dis_keyb_h200 Analog Sensor 4 Type {0=NTC 1=PT1000 2=0-1VDC 3=0-10VDC 4=4-20mA 5=ON/OFF 6=0-5VDC 7=NTC HT 8=-50T90 9=10T170}
1.3.6.1.4.1.9839.2.1.3.70 cw-fan-speed-bms, bms-address-IDENT, t_slot_cfg_rt, mm_2, f5, h_hour_fan3, remote_control00 CW Fan speed (%) sent via BMS
1.3.6.1.4.1.9839.2.1.3.71 dx-fan-speed-bms, fan_time_fe, dd_3, d1, l_hour_fan300 DX Fan speed (%) sent via BMS
1.3.6.1.4.1.9839.2.1.3.72 fan-speed-max, abilitazione_allarme_fumo, hh_3, d2, h_hour_fan400 Maximum Fan speed (% of output) modulation.
1.3.6.1.4.1.9839.2.1.3.73 fan-speed-min, abilitazione_allarme_cf, mm_3, d5, l_hour_fan400 Minimum Fan speed (% of output) modulation from pressure.
1.3.6.1.4.1.9839.2.1.3.74 fan-pr-sp, abilitazione_allarme_ht, dd_4, d6, sg_ore_fan, lan_address_sa00 Fan pressure setpoint (0.01 inches of water)
1.3.6.1.4.1.9839.2.1.3.75 fan-pr-band, hh_4, d7, version, lan_lenght_sn00 Fan pressure band (0.01 inches of water)
1.3.6.1.4.1.9839.2.1.3.76 fan-af-max, mm_4, d8, h_hour_fan5, hh_def_sched100 Maximum air flow limit of setpoint from BMS or valve modulation.
1.3.6.1.4.1.9839.2.1.3.77 fan-af-min, dd_5, d9, l_hour_fan5, mm_def_sched100 Minimum air flow limit of setpoint from BMS or valve modulation.
1.3.6.1.4.1.9839.2.1.3.78 fan-kfactor, hh_5, d10, time_on_black_out, hh_def_sched200 Fan K Factor
1.3.6.1.4.1.9839.2.1.3.79 num-fans, mm_5, d12, config_in1, mm_def_sched200 Number of fans installed in this unit
1.3.6.1.4.1.9839.2.1.3.80 dd_6, d13, config_in2, hh_def_sched300
1.3.6.1.4.1.9839.2.1.3.81 ht2-hours-h, hh_6, config_in3, mm_def_sched300 Heater 2 Runtime - high
1.3.6.1.4.1.9839.2.1.3.82 ht2-hours-l, mm_6, config_in4, hh_def_sched400 Heater 2 Runtime - low
1.3.6.1.4.1.9839.2.1.3.83 ht3-hours-h, dd_7, r27, config_in5, mm_def_sched400 Heater 3 Runtime - high
1.3.6.1.4.1.9839.2.1.3.84 ht3-hours-l, hh_7, l4, config_in6, hh_def_sched500 Heater 3 Runtime - low
1.3.6.1.4.1.9839.2.1.3.85 engy-hours-h, mm_7, h16, config_in7, mm_def_sched500 Energy Saver Runtime - This optional point applies to energy saver units only -high
1.3.6.1.4.1.9839.2.1.3.86 engy-hours-l, dd_8, p12, config_in8, hh_def_sched600 Energy Saver Runtime - This optional point applies to energy saver units only - low
1.3.6.1.4.1.9839.2.1.3.87 cw-hours-h, hh_8, l1, config_in9, mm_def_sched600 Chilled Water Runtime - This applies to chilled water units only - high
1.3.6.1.4.1.9839.2.1.3.88 cw-hours-l, mm_8, l2, config_in10, hh_def_sched700 Chilled Water Runtime - This applies to chilled water units only - low
1.3.6.1.4.1.9839.2.1.3.89 c3-hours-h, l3, config_in11, mm_def_sched700 Compressor 3 Runtime - This applies when unit has four stages tandem compressors - high
1.3.6.1.4.1.9839.2.1.3.90 c3-hours-l, l5, config_in12, hh_def_sched800 Compressor 3 Runtime - This applies when unit has four stages tandem compressors - low
1.3.6.1.4.1.9839.2.1.3.91 c4-hours-l, r14, config_in13, mm_def_sched800 Compressor 4 Runtime - This applies when unit has four stages tandem compressors. - high
1.3.6.1.4.1.9839.2.1.3.92 c4-hours-h, config_in14, hh_clock00 Compressor 4 Runtime - This applies when unit has four stages tandem compressors. - low
1.3.6.1.4.1.9839.2.1.3.93 cond-hours-h, config_in15, mm_clock00 Condenser Runtime - high
1.3.6.1.4.1.9839.2.1.3.94 cond-hours-l, config_in16, hh_vis00 Condenser Runtime - low
1.3.6.1.4.1.9839.2.1.3.95 dx-fan-speed, config_in17, mm_vis00 Fan speed (% of output) when compressor cooling.
1.3.6.1.4.1.9839.2.1.3.96 cw-fan-speed, config_in1800 Fan speed (% of output) when cold water cooling.
1.3.6.1.4.1.9839.2.1.3.97 fan-af-dx-sp, config_out100 Fan air flow setpoint for DX unit (cfm)
1.3.6.1.4.1.9839.2.1.3.98 fan-af-cw-sp, config_out200 Fan air flow setpoint for CW unit (cfm)
1.3.6.1.4.1.9839.2.1.3.99 zm-airflow-sp, chiller-name0, config_out300 Zone Airflow Setpoint kcfm
1.3.6.1.4.1.9839.2.1.3.100 chiller-name1, config_out400
1.3.6.1.4.1.9839.2.1.3.101 config_out500