OID reference

eventConfigCompareValue

1.3.6.1.4.1.1206.4.2.6.4.2.1.4

Description

<Definition>This object contains the comparison value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the value onChange (2). <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.4

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1206.4.2.6.4.2.1 (eventLogConfigEntry)
Node code
4
Node name
eventConfigCompareValue
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1206.4.2.6.4.2.1.4
URN notation
urn:oid:1.3.6.1.4.1.1206.4.2.6.4.2.1.4
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1206 4 2 6 4 2 1 4}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) global(6) globalReport(4) eventLogConfigTable(2) eventLogConfigEntry(1) eventConfigCompareValue(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) global(6) globalReport(4) defaultForegroundColor(2) eventLogConfigEntry(1) eventConfigCompareValue(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) global(6) multiCfg(4) eventLogConfigTable(2) eventLogConfigEntry(1) eventConfigCompareValue(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) global(6) multiCfg(4) defaultForegroundColor(2) eventLogConfigEntry(1) eventConfigCompareValue(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(6) globalReport(4) eventLogConfigTable(2) eventLogConfigEntry(1) eventConfigCompareValue(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(6) globalReport(4) defaultForegroundColor(2) eventLogConfigEntry(1) eventConfigCompareValue(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(6) multiCfg(4) eventLogConfigTable(2) eventLogConfigEntry(1) eventConfigCompareValue(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nema(1206) transportation(4) devices(2) dms(6) multiCfg(4) defaultForegroundColor(2) eventLogConfigEntry(1) eventConfigCompareValue(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) global(6) globalReport(4) eventLogConfigTable(2) eventLogConfigEntry(1) eventConfigCompareValue(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) global(6) globalReport(4) defaultForegroundColor(2) eventLogConfigEntry(1) eventConfigCompareValue(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) global(6) multiCfg(4) eventLogConfigTable(2) eventLogConfigEntry(1) eventConfigCompareValue(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) global(6) multiCfg(4) defaultForegroundColor(2) eventLogConfigEntry(1) eventConfigCompareValue(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(6) globalReport(4) eventLogConfigTable(2) eventLogConfigEntry(1) eventConfigCompareValue(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(6) globalReport(4) defaultForegroundColor(2) eventLogConfigEntry(1) eventConfigCompareValue(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(6) multiCfg(4) eventLogConfigTable(2) eventLogConfigEntry(1) eventConfigCompareValue(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nema(1206) transportation(4) devices(2) dms(6) multiCfg(4) defaultForegroundColor(2) eventLogConfigEntry(1) eventConfigCompareValue(4)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/1206/4/2/6/4/2/1/4
  • /ISO/Identified-Organization/6/1/4/1/1206/4/2/6/4/2/1/4
  • /ISO/3/6/1/4/1/1206/4/2/6/4/2/1/4
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/global/globalReport/eventLogConfigTable/eventLogConfigEntry/eventConfigCompareValue
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/global/globalReport/defaultForegroundColor/eventLogConfigEntry/eventConfigCompareValue
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/global/multiCfg/eventLogConfigTable/eventLogConfigEntry/eventConfigCompareValue
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/global/multiCfg/defaultForegroundColor/eventLogConfigEntry/eventConfigCompareValue
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/dms/globalReport/eventLogConfigTable/eventLogConfigEntry/eventConfigCompareValue
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/dms/globalReport/defaultForegroundColor/eventLogConfigEntry/eventConfigCompareValue
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/dms/multiCfg/eventLogConfigTable/eventLogConfigEntry/eventConfigCompareValue
  • /iso/identified-organization/dod/internet/private/enterprise/1206/transportation/devices/dms/multiCfg/defaultForegroundColor/eventLogConfigEntry/eventConfigCompareValue
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/global/globalReport/eventLogConfigTable/eventLogConfigEntry/eventConfigCompareValue
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/global/globalReport/defaultForegroundColor/eventLogConfigEntry/eventConfigCompareValue
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/global/multiCfg/eventLogConfigTable/eventLogConfigEntry/eventConfigCompareValue
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/global/multiCfg/defaultForegroundColor/eventLogConfigEntry/eventConfigCompareValue
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/dms/globalReport/eventLogConfigTable/eventLogConfigEntry/eventConfigCompareValue
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/dms/globalReport/defaultForegroundColor/eventLogConfigEntry/eventConfigCompareValue
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/dms/multiCfg/eventLogConfigTable/eventLogConfigEntry/eventConfigCompareValue
  • /iso/identified-organization/dod/internet/private/enterprise/nema/transportation/devices/dms/multiCfg/defaultForegroundColor/eventLogConfigEntry/eventConfigCompareValue
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER, Integer32
Maximum access defined by MIB
read-write
Status in MIB
mandatory, deprecated
Default value
0

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — NTCIP published standard MIB annexes (reviewed modules), ITE public NTCIP working repository MIBs

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory
Default value
0

Variant 2 — ITE public NTCIP working repository MIBs, NTCIP published standard MIB annexes (reviewed modules)

Value type
Integer32
Maximum access defined by MIB
read-write
Status in MIB
deprecated
Default value
0

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In NTCIP1201-2004, the row index eventConfigID is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.1206.4.2.6.4.2.1.4.<eventConfigID>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.1206.4.2.6.4.2.1.4

Replace the placeholders with your connection and authentication options. Some definitions do not specify a readable access value. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 8 distinct definitions; some records may not include a definition.

Show 8 published definitions

eventConfigCompareValue · mandatory

eventConfigCompareValue OBJECT-TYPE
   SYNTAX INTEGER
   ACCESS read-write
   STATUS mandatory
   DESCRIPTION
      "<Definition>This object contains the comparison value to
         use with eventConfigMode values (greaterThanValue,
         smallerThanValue, hysteresisBound ). No value within this
         object is necessary when the eventConfigMode-object has the
         value onChange (2).
        <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.4
      "
   DEFVAL {0}
::= { eventLogConfigEntry 4 }

eventConfigCompareValue · mandatory

eventConfigCompareValue OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "<Definition>This object contains the comparison value to
          use with eventConfigMode values (greaterThanValue,
          smallerThanValue, hysteresisBound ). No value within this
          object is necessary when the eventConfigMode-object has the
          value onChange (2).
         <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.4
        "
    DEFVAL {0}
::= { eventLogConfigEntry 4 }

eventConfigCompareValue · mandatory

eventConfigCompareValue OBJECT-TYPE
SYNTAX	INTEGER
ACCESS	read-write
STATUS	mandatory
DESCRIPTION
"<Definition>This object contains the comparision value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ).  No value within this object is necessary when the eventConfigMode-object has the value onChange (2). 
<DescriptiveName>EventType.compareValue:number
<DataConceptType>Data Element"
DEFVAL	{0}
::= { eventLogConfigEntry 4 }

eventConfigCompareValue · mandatory

eventConfigCompareValue OBJECT-TYPE
SYNTAX        INTEGER
ACCESS        read-write
STATUS        mandatory
DESCRIPTION
       "<Definition>This object contains the comparision value to use
       with eventConfigMode values (greaterThanValue, smallerThanValue,
       hysteresisBound ). No value within this object is necessary when
       the eventConfigMode-object has the value onChange (2).
       <DescriptiveName>EventType.compareValue:number
      <DataConceptType>Data Element"
DEFVAL      {0}
::= { eventLogConfigEntry 4 }

eventConfigCompareValue · deprecated

eventConfigCompareValue  OBJECT-TYPE
  SYNTAX      Integer32
  MAX-ACCESS  read-write
  STATUS      deprecated
  DESCRIPTION
    "<Definition>This object contains the comparison value to 
      use with eventConfigMode values (greaterThanValue, 
      smallerThanValue, hysteresisBound ). No value within this 
      object is necessary when the eventConfigMode-object has the 
      value onChange (2). 
    <Superseded by> COND-TRIGGER-MIB.fdCondTriggerValue & 
      fdCondTriggerValueOctet (ISO 20684-3)
    <Informative> The interger-based replacement object conforms to SNMPv3 
      rules and does not allow the specification of a 64-bit value 
      and requires integers to be defined as either signed or unsigned. 
      eventConfigCompareValue is perhaps ambiguous about this, although 
      SNMPv1 conventions dictate the same functionality. The result is that
      the current design does not allow for comparing large unsigned 
      integer values.
    <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.4"
   DEFVAL  {0}
::= { eventLogConfigEntry 4 }

eventConfigCompareValue · deprecated

eventConfigCompareValue OBJECT-TYPE
SYNTAX       Integer32
MAX-ACCESS read-write
STATUS       deprecated
DESCRIPTION
   "<Definition>This object contains the comparison value to use with
   eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound
   ). No value within this object is necessary when the eventConfigMode-object
   has the value onChange (2).
  <Supplanted by> ISO26048-1-CondTrigger.fdCondTriggerValue &
  fdCondTriggerValueOctet (ISO 26048-1)




                                                                                                 

                                                                                      
                                                                                     

  <Informative> The interger-based replacement object conforms to SNMPv3
  rules and does not allow the specification of a 64-bit value and requires
  integers to be defined as either signed or unsigned.
  eventConfigCompareValue is perhaps ambiguous about this, although SNMPv1
  conventions dictate the same functionality. The result is that the current
  design does not allow for comparing large unsigned integer values.
  <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.4"
DEFVAL     { 0 }
::= { eventLogConfigEntry 4 }

eventConfigCompareValue · mandatory

eventConfigCompareValue OBJECT-TYPE
SYNTAX            INTEGER
ACCESS            read-write
STATUS            mandatory
DESCRIPTION
         "<Definition>This object contains the comparison value to use with eventConfigMode
         values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this
         object is necessary when the eventConfigMode-object has the value onChange (2).
         <DescriptiveName>EventType.compareValue:number
         <DataConceptType>Data Element"
DEFVAL            {0}
::= { eventLogConfigEntry 4 }

eventConfigCompareValue · mandatory

eventConfigCompareValue OBJECT-TYPE
SYNTAX        INTEGER
ACCESS        read-write
STATUS        mandatory
DESCRIPTION



© 2001 NEMA                                                                   Copy per MIB Distribution Notice

                      
         



"This object contains the comparison value to use with eventConfigMode values (greaterThanValue,
smallerThanValue, hysteresisBound ). No value within this object is necessary when the
eventConfigMode-object has the “value onChange (2)."
::= { eventLogConfigEntry 4 }

Meaning

Descriptions

5 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

<Definition>This object contains the comparison value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the value onChange (2). <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.4

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 2

<Definition>This object contains the comparision value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the value onChange (2). <DescriptiveName>EventType.compareValue:number <DataConceptType>Data Element

Sources for this description

ITE public NTCIP working repository MIBsNTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 3

<Definition>This object contains the comparison value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the value onChange (2). <Superseded by> COND-TRIGGER-MIB.fdCondTriggerValue & fdCondTriggerValueOctet (ISO 20684-3) <Informative> The interger-based replacement object conforms to SNMPv3 rules and does not allow the specification of a 64-bit value and requires integers to be defined as either signed or unsigned. eventConfigCompareValue is perhaps ambiguous about this, although SNMPv1 conventions dictate the same functionality. The result is that the current design does not allow for comparing large unsigned integer values. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.4

Sources for this description

ITE public NTCIP working repository MIBs

See 1 matching source record

Description 4

<Definition>This object contains the comparison value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the value onChange (2). <Supplanted by> ISO26048-1-CondTrigger.fdCondTriggerValue & fdCondTriggerValueOctet (ISO 26048-1) <Informative> The interger-based replacement object conforms to SNMPv3 rules and does not allow the specification of a 64-bit value and requires integers to be defined as either signed or unsigned. eventConfigCompareValue is perhaps ambiguous about this, although SNMPv1 conventions dictate the same functionality. The result is that the current design does not allow for comparing large unsigned integer values. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.4

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Description 5

<Definition>This object contains the comparison value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the value onChange (2). <DescriptiveName>EventType.compareValue:number <DataConceptType>Data Element

Sources for this description

NTCIP published standard MIB annexes (reviewed modules)

See 1 matching source record

Evidence

Source records

6 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1NTCIP published standard MIB annexes (reviewed modules)1 record · 2 sources

Description 1

eventConfigCompareValue · mandatoryNTCIP published standard MIB annexes (reviewed modules)2 sources

Status in source: mandatory.

Names: eventConfigCompareValue

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "eventConfigCompareValue",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition>This object contains the comparison value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the value onChange (2). <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.4 \"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "eventLogConfigEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER"
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition>This object contains the comparison value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the value onChange (2). <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.4"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 2ITE public NTCIP working repository MIBs, NTCIP published standard MIB annexes (reviewed modules)1 record · 2 sources

Description 2

eventConfigCompareValue · mandatoryITE public NTCIP working repository MIBs, NTCIP published standard MIB annexes (reviewed modules)2 sources

Status in source: mandatory.

Names: eventConfigCompareValue

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "eventConfigCompareValue",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition>This object contains the comparision value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the value onChange (2). <DescriptiveName>EventType.compareValue:number <DataConceptType>Data Element\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "eventLogConfigEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER"
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition>This object contains the comparision value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the value onChange (2). <DescriptiveName>EventType.compareValue:number <DataConceptType>Data Element"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
  • ITE public NTCIP working repository MIBs · Publisher's source file: NTCIP-1201 — NTCIP1201-Glo.mib

    Module: NTCIP1201-2004

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['Opaque', 'Counter', 'Gauge', 'null'], 'RFC1213-MIB': ['DisplayString'], 'NTCIP8004-A-2004': ['devices', 'protocols', 'profiles', 'global']}

    Source data warning: This original is published in an ITE NTCIP working repository. Repository publication does not establish that this particular revision is an adopted standard. Consult its native revision history and the NTCIP published standards catalog before implementation. Copyright and distribution notices are retained in the downloadable original.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP imports: the original references NTCIP8004-A-2004, which is absent from the public repository snapshot. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    · Download NTCIP-1201 — NTCIP1201-Glo.mib
  • NTCIP published standard MIB annexes (reviewed modules) · Publisher's source file: NTCIP 1201:2005, Global Object Definitions – version 02 Published October 2005 (superceded by NTCIP 1201 v03) — original PDF · Official record

    Module: NTCIP1201-2004

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['Opaque', 'Counter', 'Gauge', 'null'], 'RFC1213-MIB': ['DisplayString'], 'NTCIP8004-A-2004': ['devices', 'protocols', 'profiles', 'global']}

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations.

    Source data warning: This record is transcribed from a published NTCIP MIB annex. The downloadable text is a derived transcription with page furniture and section headings masked; the unmodified original PDF is authoritative. Native definitions, DESCRIPTION and STATUS are retained. A published object definition does not establish support by any particular device.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP namespace references: NTCIP8004-A-2004. These exact source files require the reviewed bindings shown below. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    · Download NTCIP1201v0232f.pdf — NTCIP1201-2004 (MIB transcription)
Records for description 3ITE public NTCIP working repository MIBs1 record · 1 source

Description 3

eventConfigCompareValue · deprecatedITE public NTCIP working repository MIBs1 source

Status in source: deprecated.

Names: eventConfigCompareValue

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "eventConfigCompareValue",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "deprecated",
    "DESCRIPTION",
    "\"<Definition>This object contains the comparison value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the value onChange (2). <Superseded by> COND-TRIGGER-MIB.fdCondTriggerValue & fdCondTriggerValueOctet (ISO 20684-3) <Informative> The interger-based replacement object conforms to SNMPv3 rules and does not allow the specification of a 64-bit value and requires integers to be defined as either signed or unsigned. eventConfigCompareValue is perhaps ambiguous about this, although SNMPv1 conventions dictate the same functionality. The result is that the current design does not allow for comparing large unsigned integer values. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.4\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "eventLogConfigEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32"
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "deprecated"
    ],
    [
      "DESCRIPTION",
      "<Definition>This object contains the comparison value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the value onChange (2). <Superseded by> COND-TRIGGER-MIB.fdCondTriggerValue & fdCondTriggerValueOctet (ISO 20684-3) <Informative> The interger-based replacement object conforms to SNMPv3 rules and does not allow the specification of a 64-bit value and requires integers to be defined as either signed or unsigned. eventConfigCompareValue is perhaps ambiguous about this, although SNMPv1 conventions dictate the same functionality. The result is that the current design does not allow for comparing large unsigned integer values. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.4"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 4NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 4

eventConfigCompareValue · deprecatedNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: deprecated.

Names: eventConfigCompareValue

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "eventConfigCompareValue",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "deprecated",
    "DESCRIPTION",
    "\"<Definition>This object contains the comparison value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the value onChange (2). <Supplanted by> ISO26048-1-CondTrigger.fdCondTriggerValue & fdCondTriggerValueOctet (ISO 26048-1) <Informative> The interger-based replacement object conforms to SNMPv3 rules and does not allow the specification of a 64-bit value and requires integers to be defined as either signed or unsigned. eventConfigCompareValue is perhaps ambiguous about this, although SNMPv1 conventions dictate the same functionality. The result is that the current design does not allow for comparing large unsigned integer values. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.4\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "eventLogConfigEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32"
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "deprecated"
    ],
    [
      "DESCRIPTION",
      "<Definition>This object contains the comparison value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the value onChange (2). <Supplanted by> ISO26048-1-CondTrigger.fdCondTriggerValue & fdCondTriggerValueOctet (ISO 26048-1) <Informative> The interger-based replacement object conforms to SNMPv3 rules and does not allow the specification of a 64-bit value and requires integers to be defined as either signed or unsigned. eventConfigCompareValue is perhaps ambiguous about this, although SNMPv1 conventions dictate the same functionality. The result is that the current design does not allow for comparing large unsigned integer values. <Object Identifier> 1.3.6.1.4.1.1206.4.2.6.4.2.1.4"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 5NTCIP published standard MIB annexes (reviewed modules)1 record · 1 source

Description 5

eventConfigCompareValue · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: eventConfigCompareValue

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "eventConfigCompareValue",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"<Definition>This object contains the comparison value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the value onChange (2). <DescriptiveName>EventType.compareValue:number <DataConceptType>Data Element\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "eventLogConfigEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER"
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "<Definition>This object contains the comparison value to use with eventConfigMode values (greaterThanValue, smallerThanValue, hysteresisBound ). No value within this object is necessary when the eventConfigMode-object has the value onChange (2). <DescriptiveName>EventType.compareValue:number <DataConceptType>Data Element"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Definitions without a descriptionNTCIP published standard MIB annexes (reviewed modules)1 record · 1 source
eventConfigCompareValue · mandatoryNTCIP published standard MIB annexes (reviewed modules)1 source

Status in source: mandatory.

Names: eventConfigCompareValue

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "eventConfigCompareValue",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "©",
    "2001",
    "NEMA",
    "Copy",
    "per",
    "MIB",
    "Distribution",
    "Notice",
    [
      "literal",
      "2254686973206f626a65637420636f6e7461696e732074686520636f6d70617269736f6e2076616c756520746f207573652077697468206576656e74436f6e6669674d6f64652076616c7565732028677265617465725468616e56616c75652c0a736d616c6c65725468616e56616c75652c2068797374657265736973426f756e6420292e204e6f2076616c75652077697468696e2074686973206f626a656374206973206e6563657373617279207768656e207468650a6576656e74436f6e6669674d6f64652d6f626a656374206861732074686520e2809c76616c7565206f6e4368616e6765202832292e22"
    ],
    "::=",
    "{",
    "eventLogConfigEntry",
    "4",
    "}"
  ]
}
  • NTCIP published standard MIB annexes (reviewed modules) · Publisher's source file: NTCIP 1201:1996, Global Object Definitions Published December 2001 (superceded by NTCIP 1201 v02) — original PDF · Official record

    Module: GLOBAL

    See published definition above

    Source data warning: Recovered from a file whose complete MIB does not parse. The original assignment and definition are preserved. Registration and implementation details may be inaccurate; consult the original file. Other damaged or unresolved declarations are not established registrations. The declaration also has invalid SMI syntax; its type constraints were not validated.

    Source data warning: This record is transcribed from a published NTCIP MIB annex. The downloadable text is a derived transcription with page furniture and section headings masked; the unmodified original PDF is authoritative. Native definitions, DESCRIPTION and STATUS are retained. A published object definition does not establish support by any particular device.

    Source data warning: A typographic closing DESCRIPTION quotation delimiter occurs immediately at a native SMI field boundary. Normalize this delimiter only in the derived transcription; retain the literal published definition, full description and unchanged numeric assignments.

    Source data warning: A typographic closing quotation mark terminates a DESCRIPTION in this PDF. Normalize that delimiter only in the derived MIB transcription; preserve the literal published definition and unmodified PDF. No numeric assignment changes.

    Source data warning: A typographic opening DESCRIPTION quotation delimiter occurs immediately at a native SMI field boundary. Normalize this delimiter only in the derived transcription; retain the literal published definition, full description and unchanged numeric assignments.

    Source data warning: The GLOBAL moduleMake/moduleVersion assignment closes its explicitly opened brace with a parenthesis. Normalize only that delimiter in the derived parsing copy; retain the original definition and unchanged numeric expression.

    Source data warning: The historical GLOBAL security grouping explicitly prints the parent global and suffix 5 but omits assignment braces. Reuse two adjacent whitespace bytes for those braces in the parsing copy; retain the original expression and qualify this syntactic interpretation. No numeric arc is invented or replaced.

    Source data warning: Unconfirmed historical GLOBAL parent interpretation: the assignment names EventLogConfigTable, while its native table or entry declaration uses eventLogConfigTable. Interpret only this byte-pinned reference using that explicit local declaration. All numeric suffixes and the original published definition remain unchanged; verify the original before implementation.

    Source data warning: Unconfirmed historical GLOBAL parent interpretation: the assignment names EventLogEntry, while its native table or entry declaration uses eventLogEntry. Interpret only this byte-pinned reference using that explicit local declaration. All numeric suffixes and the original published definition remain unchanged; verify the original before implementation.

    Source data warning: Unconfirmed historical GLOBAL parent interpretation: the assignment names globalmoduleTable, while its native table or entry declaration uses globalModuleTable. Interpret only this byte-pinned reference using that explicit local declaration. All numeric suffixes and the original published definition remain unchanged; verify the original before implementation.

    Source data warning: Unconfirmed historical GLOBAL parent interpretation: the assignment names moduleTableEntry, while its native table or entry declaration uses moduleEntry. Interpret only this byte-pinned reference using that explicit local declaration. All numeric suffixes and the original published definition remain unchanged; verify the original before implementation.

    Source data warning: Potentially inaccurate interpretation of historical NTCIP namespace references: missing or unreadable imports of devices, profiles. These exact source files require the reviewed bindings shown below. The numeric roots used here are the explicit assignments in normative Annex A.2 of published NTCIP 8004 v02 (2010), physical pages 43–44. This does not establish that every historical module revision is identical. The annex also prints enterprise instead of RFC 1155 enterprises and declares Protocols while referencing protocols; those spelling interpretations are disclosed. The original IMPORTS, numeric suffixes and definitions remain unchanged. Verify both originals before implementation.

    · Download NTCIP1201v0110b.pdf — GLOBAL (MIB transcription)

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1206)

Schopp Bruce J.

Siblings (8)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1206.4.2.6.4.2.1.1 eventConfigID00
1.3.6.1.4.1.1206.4.2.6.4.2.1.2 eventConfigClass00
1.3.6.1.4.1.1206.4.2.6.4.2.1.3 eventConfigMode00
1.3.6.1.4.1.1206.4.2.6.4.2.1.5 eventConfigCompareValue200
1.3.6.1.4.1.1206.4.2.6.4.2.1.6 eventConfigCompareOID00
1.3.6.1.4.1.1206.4.2.6.4.2.1.7 eventConfigLogOID00
1.3.6.1.4.1.1206.4.2.6.4.2.1.8 eventConfigAction00
1.3.6.1.4.1.1206.4.2.6.4.2.1.9 eventConfigStatus00